130 likes | 267 Views
Collimators alignment in LSS7. D. Missiaen – 13/06/2014. A genda. M easurements of main magnets Deviation to theoretical position Concept of smooth curve Measurements and alignment of collimators R esults. Measurements of main magnets.
E N D
Collimatorsalignment in LSS7 D. Missiaen – 13/06/2014
Agenda • Measurements of main magnets • Deviation to theoretical position • Concept of smoothcurve • Measurements and alignment of collimators • Results
Measurements of main magnets • First step in a survey: the measurements of the main magnets • Theyconstitute the SU measurements Network • In LSS7, typically : • Cold ones : MQ, MB, MQTLH • Warms : MQWA, MQWB, MBW • Frommeasurementswedetermine in V and H: • Deviations to the theoretical position (in db) • Deviations to a smoothcurve ( not in db)
Measurements of collimateurs • From the real position of the main magnets • Wemeasure and realign the collimators • In V : • A global survey of all collimators • Realignment of the collimators «not declared by RP as very radioactive» whennecessary • Discussion withcollimators experts and RP to decidewhichones are still to realign • In H : • Measurement and Realignment of the collimators «not declared by RP as very radioactive» • Measurementof the collimators«declaredby RP as very radioactive» • Discussion withcollimators experts and RP to decidewhichones are still to realign
Conclusions • All collimators in LSS7 measured • All colimators «non radioactive» realigned • Among the 21 «radioactive» • 13 wererealigned • 8 were not realigned • The deviations to the theoretical position in in the GEODE database • The deviation to the smoothcurveis NOT (workis on going to have it)