1 / 12

Remove this slide before customer presentation

Remove this slide before customer presentation. This is the slide set that should be used for customer presentations. The FTD slides are for internal use. This slide set contains speaker notes. Please read them before presenting the material. The Nonlinear Problem. A 0 ,P 0. A 2 ,P 2.

loc
Download Presentation

Remove this slide before customer presentation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Remove this slide before customer presentation This is the slide set that should be used for customer presentations. The FTD slides are for internal use. This slide set contains speaker notes. Please read them before presenting the material. Group/Presentation Title Agilent Restricted 22 September 2014

  2. The Nonlinear Problem Group/Presentation Title Agilent Restricted 22 September 2014

  3. A0,P0 A2,P2 A0,P0 A3,P3 F0 in F0 out F2 out F3 out Measuring nonlinearities Wouldn’t it be nice if you could measure and display the full amplitude and phase information of each spectral component? Group/Presentation Title Agilent Restricted 22 September 2014

  4. NVNA Fast ! Accurate ! Easy to Use ! The new industry paradigm for nonlinear measurements … Agilent NVNA Group/Presentation Title Agilent Restricted 22 September 2014

  5. NVNA: Vector corrected (amplitude/phase) nonlinear measurements from 10 MHz to 26.5 GHz • Calibrated absolute amplitude and relative phase (cross-frequency relative phase) of measured spectra traceable to standards lab • 26 GHz of vector corrected bandwidth for time domain waveforms of voltages and currents of DUT • X-parameters provides unique insight into nonlinear DUT behavior • X-parameter extraction into ADS PHD block for nonlinear simulation and design • Standard PNA-X with Nonlinear features and capability … the NVNA provides industry-leading performance, accuracy, and configurability to simplify test setups and provide detailed insight into designing nonlinear components. Group/Presentation Title Agilent Restricted 22 September 2014

  6. Nonlinear hierarchy from device to system Systems Devices Modules Chips Instrument Front-ends Cell Phones Military systems Etc. Circuits Characterization and modeling Amplifiers, Multipliers, …. Transistors, diodes, … Group/Presentation Title Agilent Restricted 22 September 2014

  7. Component Characterization Opt 510 • Calibrated measurements of incident, reflected and transmitted waves of DUT. • absolute amplitude and cross frequency relative phase of measured spectra traceable to standards lab • Data displayed in frequency, time and power domains • User defined parametric displays such as dynamic I/V curves • Full A and B wave data for building models in ICcap • Integrated extension of PNA-X • Ease of use • Key Customer Benefit: • Provide strong insight into DUT behavior by measuring and displaying fundamental and harmonic input and output spectra (amplitude and phase) on a familiar, high performance PNA-X network analyzer. Group/Presentation Title Agilent Restricted 22 September 2014

  8. X-parameters are the mathematically correct extension of S-parameters to large-signal conditions. Opt 514 X-parameters will revolutionize: • Characterization, Design, and Modeling of nonlinear components and systems • Measurement based, device independent, identifiable from a simple set of measurements • Fully nonlinear (Magnitude and phase of harmonics) • Cascadable (correct behavior in mismatched environment) PNA-X: Measure device X-parms ADS: Simulate using X-parms ADS: Design using X-parms Group/Presentation Title Agilent Restricted 22 September 2014

  9. Pulse Envelope Domain Opt 518 • Vector corrected amplitude and phase of fundamental and harmonic envelope. Key Customer Benefit: Analyze memory effects in nonlinear devices. Group/Presentation Title Agilent Restricted 22 September 2014

  10. Measurement Display • View corrected waveforms in frequency, time, power and parametric domains. Currently showing absolute amplitude of ‘a’ and ‘b’ waves from device in frequency and time domain. Can also display all formats including cross-frequency phase. Group/Presentation Title Agilent Restricted 22 September 2014

  11. Phase Reference: New!! Agilent Proprietary Calibrated Phase Reference Agilent’s new, InP IC based phase reference is superior in all aspects to the existing phase reference technologies. • Advantages: • Lower temperature sensitivity • Lower sensitivity to input power • Smaller minimum tone spacing (10 MHz vs 600 MHz) • Lower frequency (10 MHz vs 600 MHz) • Much wider dynamic range due to available energy vs noise Group/Presentation Title Agilent Restricted 22 September 2014

  12. NVNA System Configuration PNA-X Network Analyzer Amplitude Calibration Vector Calibration Phase Calibration New!! Agilent Proprietary Calibrated Phase Reference X-Parameter extraction source Phase Reference Group/Presentation Title Agilent Restricted 22 September 2014

More Related