1 / 42

SIS Software Install Instructions Cookbook

SIS Software Install Instructions Cookbook. Multibeam Advisory Committee March 21, 2012 SIS 3.8.3. 1. Multibeam Advisory Committee – March 21, 2012. Contents . How to install SIS software Configure the datagram distribution software.

mahlah
Download Presentation

SIS Software Install Instructions Cookbook

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SIS Software Install InstructionsCookbook Multibeam Advisory Committee March 21, 2012 SIS 3.8.3 1 Multibeam Advisory Committee – March 21, 2012

  2. Contents • How to install SIS software • Configure the datagram distribution software NOTE: These are directions for installing the SIS software. If you are doing this to replace a corrupt database, please see the “SIS Configuration Backup” and “SIS Software Uninstall” cookbook. 2 Multibeam Advisory Committee – March 21, 2012

  3. SIS Software Install Click Here Insert the SIS software DVD. If a window does not automatically open, browse to the DVD using a file explorer and double click on the start.html file. Click on the SIS SW Installation Link. 3 Multibeam Advisory Committee – March 21, 2012

  4. SIS Software Install Click Here Once this SIS Software Installation opens up, click on the “Press here to install Seafloor Information System”. 4 Multibeam Advisory Committee – March 21, 2012

  5. SIS Software Install If a security warning pops up click run to continue the installation. 5 Multibeam Advisory Committee – March 21, 2012

  6. SIS Software Install Choose your install language. 6 Multibeam Advisory Committee – March 21, 2012

  7. SIS Software Install Click on the “Next” button to continue installation. 7 Multibeam Advisory Committee – March 21, 2012

  8. SIS Software Install Verify that this is the version and build of SIS you want to install. 8 Multibeam Advisory Committee – March 21, 2012

  9. SIS Software Install Make sure that SIS is selected as an installable component. 9 Multibeam Advisory Committee – March 21, 2012

  10. SIS Software Install Choose where you want to store you raw data and where you want to store your grid data files. 10 Multibeam Advisory Committee – March 21, 2012

  11. SIS Software Install Define the IP number or hostname of the Database server. If the database is going to be on the same machine you are running SIS (the normal operation mode) enter localhost. 11 Multibeam Advisory Committee – March 21, 2012

  12. SIS Software Install Choose the install location for the SIS software. The default value of C:\Program Files\Kongsberg Maritime\SIS\ is the normal install location. 12 Multibeam Advisory Committee – March 21, 2012

  13. SIS Software Install If you want Shortcuts to be put under the Start menu in a SIS folder simply click “Install”. Otherwise define a different folder name or click “Do not create shortcuts”. 13 Multibeam Advisory Committee – March 21, 2012

  14. SIS Software Install During the install process a dialog box will appear asking about installing a MATLAB compiler runtime, click “OK”. 14 Multibeam Advisory Committee – March 21, 2012

  15. SIS Software Install After the install is done Reboot the machine to finish the process. 15 Multibeam Advisory Committee – March 21, 2012

  16. SIS Software Install Restart SIS and reconnect with the TRU through the pulldown menu. If the TRU does not appear, Rescan, and select it. 16 Multibeam Advisory Committee – March 21, 2012

  17. SIS Software Install It is now time to import your PU settings (offsets, device settings, etc). Under the “File” menu select “Import PU parameters….” 17 Multibeam Advisory Committee – March 21, 2012

  18. SIS Software Install A dialog box will appear. Browse to the location you saved you PU parameters (normally in the E:/sisdata/common/pu_param directory. Select your saved file and click “OK”. 18 Multibeam Advisory Committee – March 21, 2012

  19. SIS Software Install Don’t worry if you see plenty of blinking red fields after doing this. Go to the “File” menu and select quit….everything will be ok. 19 Multibeam Advisory Committee – March 21, 2012

  20. SIS Software Install Start up SIS again and connect to the TRU through the pulldown menu. 20 Multibeam Advisory Committee – March 21, 2012

  21. SIS Software Install It is now time to import all of you user settings such as screen layouts, datagram subscribtions, external sensors, etc. Go the the “File” menu and select “User settings”. 21 Multibeam Advisory Committee – March 21, 2012

  22. SIS Software Install You should only load user settings from a machine with the same number of hard drives. This is not normally a problem as the usual is to load settings from the same machine. Click “Ok”. 22 Multibeam Advisory Committee – March 21, 2012

  23. SIS Software Install The “Import User Settings” dialog box will appear. Click on the file selection box for User Parameters (circled in the figure above). 23 Multibeam Advisory Committee – March 21, 2012

  24. SIS Software Install Select the User Settings parameters file. This file will end in a .params suffix. 24 Multibeam Advisory Committee – March 21, 2012

  25. SIS Software Install Click on the file selection box for “Datagram subscriptions”. 25 Multibeam Advisory Committee – March 21, 2012

  26. SIS Software Install Select the Datagram subscriptions file. This file will end in a .dgmsubssuffix. 26 Multibeam Advisory Committee – March 21, 2012

  27. SIS Software Install Click on the file selection box for “Survey templates”. 27 Multibeam Advisory Committee – March 21, 2012

  28. SIS Software Install Select the Survey template file. This file will end in a .srvtpl suffix. 28 Multibeam Advisory Committee – March 21, 2012

  29. SIS Software Install Click on the file selection box for “Projections”. 29 Multibeam Advisory Committee – March 21, 2012

  30. SIS Software Install Select the Projections file. This file will end in a .proj suffix. Make sure you DO NOT select the file that ends with a .srvtpl.proj suffix. 30 Multibeam Advisory Committee – March 21, 2012

  31. SIS Software Install Click on the file selection box for “Frame settings”. 31 Multibeam Advisory Committee – March 21, 2012

  32. SIS Software Install Select the Frames file. This file will end in a .frames suffix. 32 Multibeam Advisory Committee – March 21, 2012

  33. SIS Software Install Click on the file selection box for “External sensor settings”. 33 Multibeam Advisory Committee – March 21, 2012

  34. SIS Software Install Select the External Sensors file. This file will end in a .extsens suffix. 34 Multibeam Advisory Committee – March 21, 2012

  35. SIS Software Install Click the “Accept” button now that you have filled out all of the fields. 35 Multibeam Advisory Committee – March 21, 2012

  36. SIS Software Install Click the “Accept” button. If you are importing these settings from another sounder make sure that you change the Sounder’s serial to match the sounder you are importing for. 36 Multibeam Advisory Committee – March 21, 2012

  37. SIS Software Install Click the “Ok” button, you are done importing settings. 37 Multibeam Advisory Committee – March 21, 2012

  38. SIS Software Install Quit SIS in order to finalize the loading of the User settings. 38 Multibeam Advisory Committee – March 21, 2012

  39. SIS Software Install Start up SIS again and connect to the TRU through the pulldown menu. 39 Multibeam Advisory Committee – March 21, 2012

  40. SIS Software Install The one parameter that the above method does not correctly set (apparently) is the grid engines cell size. To fix this select “View” -> “Tear Off” -> “New Survey”. 40 Multibeam Advisory Committee – March 21, 2012

  41. SIS Software Install Change the “Number of cells in processing grid:” to 128x128 and change the “Cell size (m) to 150 for the EM122 and 5 for the EM710. It might be necessary to change to EM710’s grid cell size to 10m depending upon the size of the survey area. 41 Multibeam Advisory Committee – March 21, 2012

  42. R/V Kilo Moana’s EM122 Data Distribution settings. Datagram Distribution Configuration SIS as part of the install process wiped out the datagram distribution parameters. Open the software and add a source port of 4310 for Centerbeam Depth and a the desired IP and destination port (for the Kilo Moana’s EM120 you should enter 192.168.1.40:5634 and for the EM710 you should enter 192.168.50:5635). R/V Kilo Moana’s EM710 Data Distribution settings. 42 Multibeam Advisory Committee – March 21, 2012