ISOLDE Powering and ELENA. David Nisbet. Intro. Introduction - powering the ISOLDE complex DC Systems v pulsed systems Powering Bends, Quads and Steerers Controls and diagnostics Estimate of ELENA requirements Conclusions. Introduction - powering the ISOLDE complex. Machine layout.

maille
Download Presentation

ISOLDE Powering and ELENA

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ISOLDE Powering and ELENA David Nisbet ELENA Powering 24/1/2012

  2. Intro • Introduction - powering the ISOLDE complex • DC Systems v pulsed systems • Powering Bends, Quads and Steerers • Controls and diagnostics • Estimate of ELENA requirements • Conclusions ELENA Powering 24/1/2012

  3. Introduction - powering the ISOLDE complex • Machine layout ELENA Powering 24/1/2012

  4. Introduction - powering the ISOLDE complex • The ISOLDE complex, with many beam lines, is a diverse user of beams, beam treatment and experiments • Currently the entire complex uses >500 systems under the management of TE-EPC • Grouped into >50 different types • Range from [10V to 60kV] and [500uA to 1kA] • The many beam treatments in the complex leads to a large diversity of equipment (see Fredrik Wenander presentation) • Also due to the historical ‘growth’ of the complex through CERN and non-CERN developments ELENA Powering 24/1/2012

  5. Introduction - powering the ISOLDE complex • The power converter types at ISOLDE ELENA Powering 24/1/2012

  6. DC electrostatic powering • Recommendation • Minimise the flavours found in the accelerator • Cheaper; easier to operate and maintain; • As the systems are DC • Very low power is required • Systems are physically small -> up to 30 per rack ELENA Powering 24/1/2012

  7. DC electrostatic powering • The power converter types used for ISOLDE transfer lines and recommended for use on future projects • If the proposals don’t fit with the accelerator needs • Straight forward to extend up to 35kV and 35W • Try to standardise! http://www.fug-elektronik.de/webdir/PDF/e/e_datasheet_HCE.pdf ELENA Powering 24/1/2012

  8. Pulsed electrostatic powering • Additional constraints on the choice of power converter • Power source needs to sink and source current quickly • Peak current and power is much higher • The voltage rise and fall time is a critical parameter • Not available ‘off the shelf’ from commercial suppliers • EPC currently have very few pulsed systems in the ISOLDE complex • Kickers are required for ejection from ring and into experimental areas • These are generally the responsibility of the TE-ABT group • Check if the ABT group already have appropriate technology • ELENA will probably need pulsed quads to compensate dipole effects • Typical solution would switch rapidly between 2 DC sources using semiconductor switches; other solutions can be envisaged. • Synergy with kicker technology? Otherwise some development required. ELENA Powering 24/1/2012

  9. Powering bends, quads and steerers • Preferred configurations if permitted by optics: 1x unipolar 1x unipolar 4x unipolar Bending configuration 1x negative 1x positive Quad configurations Steerer configuration ELENA Powering 24/1/2012

  10. Controls and diagnostics • For DC systems, we currently use PLCs in the ISOLDE complex • Provides a slow control and acquisition solution for general monitoring • Acquisition of output voltage and power system state is generally sufficient • Specification of setpoint and measurement performance? 10-4resolution and 10-4 absolute ? • Acquisition of Pulsed Systems • In addition to the slow (PLC) control, triggers and fast acquisition are required • Standard solutions available from the CO group would typically be used • Check also synergies with the TE-ABT group ELENA Powering 24/1/2012

  11. An ELENA TL shopping list for power Approx budget: 500 kCHF ELENA Powering 24/1/2012

  12. Conclusions • Simple approach is best for the many small DC power sources required • Only a few types need to be considered compared to ISOLDE complex • Straightforward to extend to 35kV for modest cost • Pulsed approach needs much more care • Load capacitance, switching times, diagnostics • Possibly the TE-ABT group have a solution ready to go? • Consideration should be given to diagnostics requirements • Acquisition rateand acquisition performance (eg 10-4 absolute measurement performance required?) ELENA Powering 24/1/2012