510 likes | 794 Views
Isolde new vistar and Isolde beam interlocks. OP DAYS 2009. Emiliano Piselli - Jose-Luis Sanchez Alvarez BE-OP-PSB. Outline. ISOLDE. Where? What?. Isolde Beam. Vistar. Display infos. VISTAR... FDF (Fixed Display Framework). Interlocks system. Configuration GUI. Conclusions. ISOLDE.
E N D
Isolde new vistar and Isolde beam interlocks OP DAYS 2009 Emiliano Piselli - Jose-Luis Sanchez Alvarez BE-OP-PSB
Outline ISOLDE Where? What? Isolde Beam Vistar Display infos VISTAR... FDF (Fixed Display Framework) Interlocks system Configuration GUI Conclusions
ISOLDE On-Line Isotope Mass Separator Spallation Fission 1.4GeV p Fragmentation Cortesy E. Siesling
ISOLDE On-Line Isotope Mass Separator Cortesy E. Siesling
ISOLDE PSB layout
ISOLDE GPS...General Purpose Separator HRS...High Resolution Separator 7
ISOLDE Isolde layout GPS target HRS target BTY line from PSB Cortesy E. Siesling 8
ISOLDE Isolde layout HRS GPS Protons Physics! Cortesy E. Siesling
ISOLDE Target Cortesy E. Siesling
ISOLDE Secondary beam accelerated VERT HOR Cortesy E. Siesling
p+ p+ p+ p+ p+ p+ ISOLDE Target Target Converter Converter Target Standard Cortesy E. Siesling 12
ISOLDE Proton beam focusing • Standard focus • Waist of beam at target(converter targets) Fragmentation, Spallation, Fission Fragmentation, Spallation,Fission n n n n Cortesy E. Siesling
ISOLDE Focusing elements GPS focus HRS focus Cortesy E. Siesling
ISOLDE Focus settings • At each target-change:Focus settings of the proton beam depend on the type of target and will be applied and verified by the ISOLDE Machine Supervisor Cortesy E. Siesling
ISOLDE WrongBeam Liquid metal target: Cracked container welds Converter target: Twisted W convertor rod Cortesy E. Siesling
ISOLDE Steering elements GPS steering HRS steering
ISOLDE Steering settings • At each target-change:Proton Scan: Final steering of the proton beam is done by the ISOLDE Machine Supervisor Cortesy E. Siesling
ISOLDE Isolde beam • Focus settings… • Steering settings… • Max intensities (ppp & pps)
VISTAR Display BEAM informations CONTACT TARGET
VISTAR 21
VISTAR 22
VISTAR 23
VISTAR 24
VISTAR FDF (Fixed Display Framework) Library used to create a controls & monitoring java-based fixed displays. • Multiple GUI solutions are supported: • XML definition with SwiXML (also generated) for simple layouts • Pure Java JFrames (with any Java GUI Builder) for complicated cases It integrates multiple CERN components like AscBeans (lables, tables, etc) & JDataViewer It integrates integrates other basic components like TimeDate & “Diode”… Main principle used to create FDs is to define them in XML.The XML files contain a description of all the components (labels, charts, etc.) and layout of each screen. FDF architecture uses japc-monitoring and this configuration typically contains the XML file definition of the japc parameters to be monitored.
<Plots> <Plot id="hrs_ppp" update="HISTORY" title="HRS protons per pulse"> <StyleSheets> <StyleSheet> chart { legendVisible : false; legendPosition : SOUTH; } dataset[name='ppp'] { stroke : stroke(2); markerSize : 5; markerType : DIAMOND; strokeColor : #000082; } axis[axis=Y] { min: 0.0; max: 4400.0; } scale[axis='Y'] { title: "ppp"; } </StyleSheet> </StyleSheets> <Serie parameterId="ppp" name="Protons per pulse" maximumItemCount="1000"> <YValues field="value"/> </Serie> </Plot> <Plot id="hrs_curr" update="HISTORY" title="HRS protons current"> <StyleSheets> <StyleSheet> chart { legendVisible : false; legendPosition : SOUTH; } dataset[name='prCurr'] { stroke : stroke(2); markerSize : 5; markerType : SQUARE; strokeColor : #000082; } axis[axis=Y] { min: 0.00; max: 2.20; } scale[axis='Y'] { title: "uA"; } </StyleSheet> </StyleSheets> <Serie parameterId="prCurrA" name="proton current in uA" maximumItemCount="1000"> <YValues field="value"/> </Serie> </Plot> </Plots>
Interlock system TARGET Display BEAM BEAM informations CONTACT Interlock system
Interlock system Beam 2 Isolde PSB layout
Interlock system Measurement devices PSB layout
Interlock system PSB layout
Interlock system BTY.TRA325 PPS device PPS interlock: Average1’(AQN(device))≤MAX PPS
Interlock system BTY.QDE321 BTY.QFO322 FOCUS devices Focus interlock: Setting(device)-2≤ AQN(device)≤Setting(device)+2
Interlock system BTY.DHZ323 BTY.DVT324 Pos. devices Position interlock: Setting(device)-1 ≤ AQN(device) ≤ Setting(device)+1 34
Interlock system BTY.TRA325 Watchdog devices
Interlock system PSB layout
Interlock system BTY.TRA325 BT.TRA Watchdog devices Watchdog interlock: BT.TRA-BTY.TRA325<300E10 Need HARDWARE interlock RESET!
Interlock system Booster ring TRANSFO PPP device 38
Injection Ejection Interlock system Int.[ppp] I(300) 0 275 300 805 1200 t [ms] PPP interlock: I(300)≤ MAX PPS 39
Interlock system BEAM BACK SW RESET RF Condition OK 40
Interlock system HW Interlock HW RESET BEAM BACK 41
Supervisor name DB fixed_display Supervisor phone number Experimental contact Target name Genaral comment Configuration GUI 45
Supervisor name Supervisor phone number Experimental contact Target name Genaral comment Configuration GUI DB fixed_display 46
DEVICE Focus DB fixed_display Max Intensity Max proton per pulse Pos. DHZ Pos. DVT Configuration GUI Beam Label Beam type Focus Max Intensity Max proton per pulse Pos. DHZ Pos. DVT 48
Configuration GUI Special FOCUS disable Position and focus interlock 49
Conclusions ...Isolde VISTAR is CO standard and fully CO supported ...Isolde VISTAR contains many informations extremelly useful for the users and PSB team. ...Isolde Interlock system is very fast...reaction time smaller than 10ms. 50