80 likes | 214 Views
RCT Shift Report 24 June, 2009. Michalis Next shifter: Christos. RCT shift report. 1. July 1, 2009. 18-crate pattern test known problems. Exclusively run by Kira Known problems EM Crate 4 :2 bit stuck low (GCT)
E N D
RCT Shift Report24 June, 2009 Michalis Next shifter: Christos RCT shift report 1 July 1, 2009
18-crate pattern test known problems • Exclusively run by Kira • Known problems • EM Crate 4 :2 bit stuck low (GCT) • Adjusted GCT cable, went away ,back on 12 March,gone on 27th March back 17 April • EM crate 15:all noniso 4 bit stuck low (came went came)(GCT) went away after adjustments on GCT -reappeared same day • J/S crate 13, card 0 regions 0/1—512 bit stuck low(intermittent occurrence) • J/S crate 15, card 1, regions 0/1 2 bit stuck low (GCT) • Went away after readjustments by GCT but reappeared later • J/S crate 15, card 3,regions 0/1-- 32 bit stuck low (GCT) • Appeared after GCT Intervention • J/S crate 15, cards 5,6, regions 0,1 –unplugged source card • J/S crate 0 –cards 5/6 unplugged source card • HF: crates 0,15,all –unplugged source cards • HF crate 5 Crads 1/3 have 64 bit stuck low • Appeared Feb 23d,gone April 14th , reappeared May 22 RCT shift report 2 July 1, 2009
Pattern tests: New Problems • EM Crate 1 , card 6 Possible sharing problem • Needs more investigation RCT shift report 3 July 1, 2009
DCS status summary • More or less everything went OK • A spike in temperature for 5 mins last Friday • A network outage for 1 min • When we restarted RCT the FSM had dead status • Known problem with CERN DCS FSM framework • Needs restarting the FSM node • Asked Bobby to do it • Everything fine after that RCT shift report 4 July 1, 2009
Shift phone • Call On Tuesday 23:00 • Trigger shifter asked if they were using the correct RCT key • Replied yes but Pam also verified it • Call ON Tuesday 00:10 • RCT failed to configure • Manually destroyed cell and asked them to retry • It worked even if they didn't believe it would RCT shift report 5 July 1, 2009
Data quality monitoring • CRUZET started Monday Morning • Masked SCs and Fibers:Monday • HF:RCT 11 eta=30 phi odd • ECAL:RCT 0-8 , RC 4 & 5, ieta =17 ,phi odd and even for EE-/EB- edge • ECAL: RCT crate 15, card 6 region 1 ECAL • ECAL EE+8 masked , ieta 18-28 phi even and odd • More masking due to high rates • Masked RCT 5 RC 3 eta 9-13,15,16 phi odd(starting run 101644) • Masked RCT 5 RC 6 eta=25-28 odd and phi even (starting 101649) • Masked RCT 5 , RC3 eta 14 after 101649 due to operator error RCT shift report 6 July 1, 2009
Wednesday Current masks: a - HF: RCT 11 eta=30 phi odd b - ECAL: RCT 0-8, RC 4 & 5, ieta = 17, phi odd and even for EE-/EB- edge c - ECAL: RCT Crate 15 Card 6, region 1 ECAL d - ECAL: EE+8 masked, ieta 18-28 phi even and odd e - HCAL: RCT 5 RC 3 eta 9-16 phi odd (except eta = 14 in region 1 before run 101649) f - HCAL: RCT 5 RC 6 eta 25-28 phi odd and phi even
According to Marc /data are not in DBS yet so we could not run the DQM today! DQM Runs RCT shift report 8 07/01/09