Natural Gas Pipe Sizing. Procedure:. Find the longest run from the gas meter to the farthest appliance. Use linear feet. Add up the Btuh input of all appliances connected to this gas line. Enter the table at the longest run column and don’t get out of it again.
E N D
Procedure: Find the longest run from the gas meter to the farthest appliance. Use linear feet. Add up the Btuh input of all appliances connected to this gas line. Enter the table at the longest run column and don’t get out of it again. Size all piping using this column (mains, branches, etc.).
Longest run = 15 + 10 + 3 + 3 + 46 + 2 = 87 Linear Feet 8 +
Total Btuh input of all appliances = 45 + 60 = 290,000 Btuh 100 + 50 + 35 +
Longest run = 87’ Pipe size = 1 ¼” Total input = 290 MBH
1 ¼” 290 – 150 = 140,000 Btuh
Pipe size = 1” 140 MBH
1 ¼” 1” 140 – 35 = 105,000 Btuh input
105 MBH Pipe size = 1”
1 ¼” 1” 105 – 45 = 60,000 Btuh input
60 MBH Pipe size = ¾”
¾” 1 ¼” 1” Boiler and Hot Water Heater branch line = 150,000 Btuh
150 MBH Pipe size = 1”
1” ¾” 1 ¼” 1” Hot Water Boiler branch line = 100,000 Btuh
100 MBH Pipe size = 1”
1” 1” ¾” 1 ¼” 1” Hot Water Heater branch line = 50,000 Btuh
50 MBH Pipe size = ¾”
1” ¾” 1” ¾” 1 ¼” 1” Clothes drier branch line = 35,000 Btuh
35 MBH Pipe size = ½”
1” ¾” 1” ½” ¾” 1 ¼” 1” Range/Oven branch line = 45,000 Btuh
45 MBH Pipe size = ¾”
¾” 1” 1” ½” ¾” ¾” 1 ¼” 1” Finished. Make-up your pipe and fitting list.
Any questions? Thank you for your time and attention.