1 / 23

USAFSAM BRAC PLAN

USAFSAM BRAC PLAN. 22 March 2010 Maj Donna Fox. Departments of Epidemiology Laboratory First to move – Immunodiagnostics Sections of Immunodiagnostics Phasing of personnel and instrumentation Modular facility for testing Preparations both at Brooks City-Base and at Wright-Patterson AFB

may-mason
Download Presentation

USAFSAM BRAC PLAN

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. USAFSAMBRAC PLAN 22 March 2010 Maj Donna Fox

  2. Departments of Epidemiology Laboratory First to move – Immunodiagnostics Sections of Immunodiagnostics Phasing of personnel and instrumentation Modular facility for testing Preparations both at Brooks City-Base and at Wright-Patterson AFB Transition of testing The effects of moving in relation to customer care – minimal  “We’re Moving – Not Closing”

  3. Brooks City-Base Lab • Departments of the Epi Laboratory • Immunodiagnostics • Microbiology • Virology • Bacteriology • Parasitology • Molecular • Shipping/Receiving • Customer Service

  4. PHE FY 2009 WORKLOADTotal Tests: 2,039,587Immunodiagnostics Tests: 1,896,006Other PHE Tests: 143,581

  5. Immunodiagnostics • Largest department in the Epi Laboratory • Performs over 90% of patient workload • Chosen to relocate first due to size of instrumentation and workload volume

  6. Sections of Immunodiagnostics • HIV • HEPATITIS • EIA • BIOPLEX • IFA • GC/CHLAMYDIA

  7. Sections of Immunodiagnostics • HIV • Automated testing performed on Siemens Centaur XP analyzer: HIV Screens • Semi-Automated testing performed using BioRad AutoBlot 3000: HIV Western Blots • Hepatitis • Automated testing performed on Siemens Centaur Classics: HEPATITIS (A, B, C) PANELS • Reflex testing for HEPATITIS B positive results • Manual HBeAg/HBeAb ELISA testing

  8. Siemens Centaur Classic/XP

  9. BioRadAutoBlot 3000 Semi-Automated Western Blot analyzer

  10. Sections of Immunodiagnostics • Enzyme Immunoassay (EIA) • Tests performed on Trinity-Biotech DSX analyzer: CMV G/M, H. Pylori, Lyme AB, Rubeola, Mumps, Varicella • Tests performed on BioRad Bioplex analyzer: ANA, EBV G/M, HSV I/II, Syphilis

  11. Trinity DSX and BioRadBioplex

  12. Sections of Immunodiagnostics • Immunofluorescent Assay (IFA) • Confirmatory Western Blot methods performed: CMV M and Lyme M • Manual tests performed: Auto-Antibody, Coccidioides, FTA-ABS, Mycoplasma, Q Fever G/M, Rickettsia, VDRL

  13. Sections of Immunodiagnostics • Miscellaneous Testing • Automated testing performed on Gen-Probe Tigris analyzer: Gonorrhea/Chlamydia • Automated testing performed on Siemens Centaur XP analyzer: Rubella G/M, Toxoplasma, Thyroid AB

  14. Gen-Probe Tigris

  15. BRAC Personnel • Movement of military and civilian personnel in 3 phases • Phase 1 – ADVON team of 6 military and 2 civilian members PCSing in June 2010 • Phase 2 – 3 military and 2 civilian members PCSing in December 2010 • Phase 3 – 2 civilian members PCSing in January 2011 • TDY – 2 civilian personnel being sent TDY to Wright-Patterson for validation studies on instrumentation

  16. BRAC Analyzers • Movement of instrumentation in 2 phases • Phase 1 – July 2010 • 2 Bioplex analyzers (1 moved from BCB to WP and 1 new one from BioRad) • 2 Tigris analyzers – brand new from GenProbe • 4 Centaur analyzers – brand new from Siemens • Phase 2 – Jan 2011 • 1 Bioplex analyzers (BCB) • 1 Tigris analyzer (BCB)

  17. Modular Bldg (A.K.A.-Trailer) Floor Plan - Immunodiagnostics

  18. Preparations while at BCB • Upfront plans completed prior to move • Interop CHCS test files • Contracts – Equipment (new and reagent rental, Personnel, Supplies) • Accreditations (CAP, CDC, etc.) • OIs/SOPs, Policies, Procedures

  19. Preparation for Testing at WP • Moving trucks arrive 1 Jul 2010 • Unpacking and Laboratory Set-up • Computer set-up/access • Vendors and analyzers • Validation • Vendors • Technical Supervisors • Initial testing scheduled to begin 1 Oct 2010

  20. Testing Samples • Transition of patient samples to WP • Timeline By Base • 30% – 15 Oct 2010 • 50% - 15 Nov 2010 • 70 % - 15 Dec 2010 • 100% - 1 Jan 2011 • Volunteers • Contact Annette Compton • CAP Inspection

  21. Streamlined Process • Dual-Operations • Full transition to Wright-Patterson • 6 month process • Turn-Around Times • Maintained • Modular Bldg • 18-month contract – 1 Jan 2012 • Transition to new facility after everyone else • Instrumentation

  22. Summary • Breakdown of the Epi labs departments and sections • Analyzers used for testing • Transition of personnel and equipment to Wright-Patterson • Testing samples and streamlining the ability to perform dual-operations • Your ADVON team members

  23. Questions? United States School of Aerospace Medicine Epidemiology Laboratory Service (USAFSAM/PHE) 2730 Louis Bauer Drive Brooks City-Base, TX 78235-5132 EPI Lab Customer Service Team DSN: 240-8378 Commercial: 210.536.8378 Email: epilab.help@brooks.af.mil Website: https://kx.afms.mil/epi/

More Related