1 / 14

Direct Reactions at Eurisol

B. Fern ández-Domínguez. Direct Reactions at Eurisol. In the light of the TIARA+MUST2 campaign at GANIL. B. Fern ández-Domínguez. Physics Motivation. EURISOL FW5 report : SCIENTIFIC CASE (Appendix A):.

mick
Download Presentation

Direct Reactions at Eurisol

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. B. Fernández-Domínguez Direct Reactions at Eurisol In the light of the TIARA+MUST2campaign at GANIL

  2. B. Fernández-Domínguez Physics Motivation EURISOL FW5 report : SCIENTIFIC CASE (Appendix A): Direct reactions are a unique tool to uncover and investigate new manifestations of nuclear structure of exotic nuclei • Elastic and inelastic scattering -> nuclear and transition densities • Transfer, knock-out and break-up reactions -> microscopic shell-structure • Inverse kinematics • Detection: • light charged particles • gamma-rays • neutrons • beam-like particles

  3. Instrumentation for Direct Reactions B. Fernández-Domínguez EURISOL FW5 report : INSTRUMENTATION (Appendix E): Array for light charged-particle and gamma-array measurements: GRAPA(Gamma-Ray And Particle Array) Updated version: http://ns.ph.liv.ac.uk/eurisol/spec_expts/M2.1_apparatus.pdf • Charged Particles: (Particle Array ) Solid-angle of 4 x~0.1,0.5 mm and θ~ 1-5 mrad Large dynamic range with PID to Z=10 RIB • Gamma and fast charged particles : (Gamma Array) Solid-angle of 4 Best efficiency and resolution Integration of cryogenic and polarised targets.

  4. Preliminary design work required 3700 keV 2004.6 keV 1655.7 keV 1560.9 keV 853.7 keV 133Sn B. Fernández-Domínguez - SIMULATIONS: Modelling of a number of potential key experiments proposed, study different configurations etc… - IN-BEAM TEST TO VALIDATE DESIGN CHOICES: To asses the methodology and feasibility of the design concept. SIMULATIONS: • Key experiments: • 78Ni(d,p)79Ni @ 10 MeV/u • 132Sn(d,p)133Sn @ 10 MeV/u

  5. Preliminary design work required:SIMULATIONS B. Fernández-Domínguez Particle Array: (energy and angular resolution) • Target Thickness • Interaction Point Gamma Array: • Scintillating material : (CsI, LaBr3)

  6. Preliminary design work required:IN-BEAM TESTS B. Fernández-Domínguez TIARA-MUST2 CAMPAIGN AT SPIRAL/GANIL September – November 2007 -Si-array ->Array of silicon detectors covering 90% of 4pi. MUST2 and TIARA -Ge-array->EXOGAM -Spectrometer ->VAMOS Large step towards an integrated particle-gamma ray array. Results can be used to validate the design choices of the new EURISOL array (d,p) with 20O and 26Ne beams at SPIRAL : Study of the N=16 shell gap 20O-> Location of the d3/2 state in Oxygen neutron rich isotopes 26Ne->Reveal isomeric f7/2 intruder that competes with sd ground state

  7. Preliminary design work required:IN-BEAM TESTS B. Fernández-Domínguez EXOGAM Gamma-ray array MUST2 Si-CsI VAMOS spectrometer GANIL radioactive beam - 20O (SPIRAL) 10.9 A MeV 104 pps TIARA silicon array Triple coincidences: Target-like particles – TIARA/MUST2 Beam-like particles - VAMOS Gammas - EXOGAM Trigger: hit in Si-detector CD2 target 0.5 mg/cm2 Detectors E, E, TOF B, 

  8. B. Fernández-Domínguez TIARA: Inner and Outer Barrel +Hyball TIARA – Two Barrels: 8 detectors, x 4 longitudinal strips each. -Inner Barrel-> Energy, position. (E~ 200 keV, θ~1-2 deg) -Outer Barrel- identification. (30-140 deg) - Hyball, 6 wedges, x16 rings (radial), x 8 sectors (azimutal) (E~ 50 keV, θ~2 deg) (150-175 deg)

  9. B. Fernández-Domínguez MUST2: 4 Telescopes of Si+CsI MUST2 4 telescopes of Si-CsI placed at forward angles. (0-30 deg) Si-Strip – 4 modules x128x128 Energy, position. E~ 50 keV, θ~0.22 deg (pitch size 0.7mm at 180 mm) CsI- 4 modules with 4x4 crystals Identification E-E

  10. B. Fernández-Domínguez TIARA+MUST2 coupled to VAMOS • Identification of the recoil • VAMOS: • Ionisation Chamber->E • Plastic ->E, TOF Drift Chambers ->X,Y,θ,

  11. B. Fernández-Domínguez TIARA+MUST2 coupled to VAMOS +EXOGAM • Gamma detection with • EXOGAM • 4 Clovers @ 90 deg • 15% photopeak efficiency @ 1.3 MeV

  12. E (MeV) g.s 1st 1.28 MeV (d,p) θ (degrees) BOUND STATES E (MeV) SIMULATION Geant4 g.s θ (degrees) B. Fernández-Domínguez SPIRAL: RADIOACTIVE BEAM of 20O: d(20O,p)21O  21O + Preliminary (on-line results)

  13. E (MeV) (d,p) θ (degrees) UNBOUND STATES E (MeV) SIMULATION Geant4 E (keV) θ (degrees) B. Fernández-Domínguez SPIRAL: RADIOACTIVE BEAM of 20O: d(20O,p)21O  20O +n Preliminary (on-line results)

  14. SUMMARY • Simulations reproduce response of arrays and give insight into the main parameters that contribute to performance • Online analysis of the experiment confirms we can study different reactions channels, obtain level energies and l-values information • The feasibility of the methodology is demonstrated. • transfer to bound and unbound states with full channel identification • triple coincidences with excellent gamma energy resolution • also have (d,d’) and (d,t) acquired simultaneously with TIARA and MUST2 • to include unbound states requires the large VAMOS angle/momentum bite • type of experiments will be important to learn for the future array. FUTURE • Increase efficiency of particle-gamma coincidences.. • Gamma detection better efficiency, allow for fast-particle detection simultaneously • Improve performance of particle array. (Energy resolution, low thresholds) • Possibility to introduce cryogenic or polarised targets

More Related