1 / 22

Traian PETRISOR Master 2 Internship Internship Coordinator Ursula EBELS

Magnetization dynamics at high frequencies FMR using an inductive method. Traian PETRISOR Master 2 Internship Internship Coordinator Ursula EBELS. Motivation. Importance of magnetization dynamics in new devices:. MRAM, Magnetic Random Access Memories; RF oscillators;.

nelly
Download Presentation

Traian PETRISOR Master 2 Internship Internship Coordinator Ursula EBELS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Magnetization dynamics at high frequencies FMR using an inductive method Traian PETRISOR Master 2 Internship Internship Coordinator Ursula EBELS

  2. Motivation Importance of magnetization dynamics in new devices: • MRAM, Magnetic Random Access Memories; • RF oscillators; • High Frequency Characterization of Materials for the mentioned applications • Replacement of the classical FMR techniques with a broadband measurement; 1

  3. Magnetization Dynamics Heff q M F Equation of motion: precession 2

  4. Magnetization Dynamics Heff q M F Landau-Lifschitz-Gilbert equation: damping precession • precession frequencies are in the GHz range, while relaxation proccesses • are of the order of ns; 3

  5. Ferromagnetic Resonance • uniform oscillation mode; Excitation: External radio frequency magnetic field FMR: 4

  6. The Coplanar Waveguide Critical parameters in determining Z:-central line width; -gap width; -substrate dielectric constant; -line conductivity. 5

  7. What do we measure in a FMR experiment? 6

  8. What do we measure in a FMR experiment? • for the radio frequency field we • have a harmonic behaviour: • for small oscillations, we have • harmonic solutions for mx: • so that: • if we consider 7

  9. Transmission Line Theory TEM(Transverse Electric and Magnetic Fields) mode of propagation Telegrapher’s Equations: • characteristic impedance • V and I are traveling waves having a propagation constant, 8

  10. 9

  11. The Vector Network Analyzer • in order to perform an FMR experiment and obtain c, we have two • basic requirements: • Radio frequency pumping field, hrf ; • Measurement of DZ ; • Solution: use of the Vector Network Analyzer (VNA) 10

  12. The Vector Network Analyzer S21 Transmitted Incident a1 b2 S11 Reflected Reflected S22 b1 a2 S12 Transmitted Incident • at high frequencies it is difficult to measure voltages and currents, • → use of S-parameters • the S-parameters are determined by measuring the incident, reflected • and transmitted power; 11

  13. Using the S-Parameters Localized impedance 12

  14. The Vector Network Analyzer Calibration • in order to make relevant measurements the Network Analyzer has to be • calibrated; • Calibration Process:-determination of the systematic sources of errors • by measuring known standards (SOLT); • - mathematical removal of the errors from subsequent • measurements; • - shifting the reference planes of the measurement; 25ps Delay Line • we find 13

  15. The Studied Samples • pre-existing Coplanar Waveguides with 100nm thick Py lines on top; • the lines were fabricated from Cu/Ta on high resistivity Si substrate; • designed to have a Zc=50W→TEM propagation mode; 900µm Access port Access port • central line width: 5µm; Py line width: 4µm • the lines did not show the expected behavior, non-TEM propagation mode; 14

  16. The Studied Samples • pre-existing Coplanar Waveguides with 100nm thick Py lines on top; • the lines were fabricated from Cu/Ta on high resistivity Si substrate; • designed to have a Zc=50W→TEM propagation mode; 900µm Access port Access port • the lines did not show the expected behavior, non-TEM propagation mode; 15

  17. Measurement Protocol in an FMR Experiment Signal measurement, precession Reference measurement, no precession Substraction of the two contributions 16

  18. Extraction of dynamic susceptibility • the results are not in agreement with the theoretical behaviour; • Reason: we did not take into account propagation effects, we used the localized • impedance model; 17

  19. Extraction of dynamic susceptibility • the results are in agreement with theoretical behaviour; 18

  20. Conclusion • After phase correction the results are in good agreement with expected behaviour. 19

  21. Perspectives 900µm Access port Access port • Improvement of the coplanar waveguides: • - change of geometry; • - oxyde layer between substrate and lines; • Extraction of the dynamic susceptibility using the • equivalent circuit approach; • Removing access port contribution from measurements by performing different calibration • (ex. TRL, LL); • Characterization of different materials and structures. 20

  22. Acknowledgments I would like to express my gratitude towards Ursula EBELS for her constant help and support during the entire period of the internship and to Bernard VIALA and Jean-Philippe MICHEL for their patience and support in preparing this presentation 21

More Related