150 likes | 284 Views
Trigger Bias Study at Test Bench Data. RIKEN/RBRC Itaru Nakagawa. Recompile Code. Recompiled ~/work/Ana/mutrver01 and renewed bin/ and lib directories. After recompile. Before recompile. dat100604/bkp/feeclus02.root . dat100604/feeclus02.root .
E N D
Trigger Bias Study at Test Bench Data RIKEN/RBRC Itaru Nakagawa
Recompile Code Recompiled ~/work/Ana/mutrver01 and renewed bin/ and lib directories After recompile Before recompile dat100604/bkp/feeclus02.root dat100604/feeclus02.root They are absolutely identical. Events in fADC[2]<fADC[0] region are still missing.
Calibration Pulse default Reflection? Measurements are done without recap clamp dat100615/pulse001.cdat dat100615/pulse001.cdat
Timing Check dat100615/pulse002.cdat dat100615/pulse002.cdat dat100615/pulse003.cdat dat100615/pulse003.cdat
Timing Check dat100615/pulse004.cdat dat100615/pulse004.cdat dat100615/pulse005.cdat dat100615/pulse005.cdat
Timing Check dat100615/pulse006.cdat dat100615/pulse006.cdat dat100615/pulse007.cdat dat100615/pulse007.cdat
Timing Check trigger 3.6us dat100615/pulse008.cdat dat100615/pulse008.cdat dat100615/pulse009.cdat 3.8us dat100615/pulse009.cdat
Backup Scintillator Trigger collimator 90 Sr Chamber f=+3.5cm r=27.5cm Trigger scintillator Trigger scintillator
Trigger Timingw/ 90Sr delay:2BCLK Back Up Scintillator Trigger Strip#26 (E47) Difficult to observe correlated signal with trigger on scope.
ADC[2] .vs ADC[0] dat100614/feeclus002.root dat100614/feeclus003.root 20k events 500k events Scintillator HV=-1600V Scintillator HV=-1700V Only ADC2=ADC0 exists in large ADC region. dat100614/feeclus004.root Scintillator HV=-1600V 50k events Perhaps chamber penetrated trigger may not cause large pulse in chamber?
Timing Tune with Cosmic Default timing so far. trigger Strip 26 data012.cdat data012.cdat 3.8us data013.cdat data013.cdat
More Statistics w/ Cosmic dat100616/feeclus002.root 500k events 3.8us
90Sr Source (Delay=3.8us) Scitillator HV=-1700V Threshold=-200mV dat100615/feeclus014.root Scitillator HV=-1800V Threshold=-100mV dat100616/feeclus003.root
Summary • Trigger timing was tuned with calibration pulse. • Scintillator trigger timing was also optimized based on calibration timing (3.8us). • ADC2 .vs ADC0 correlation shows uniform distribution below MIP region (ADC<200). (Should be ADC2~5*ADC0 if correlated timing) • Beyond MIP region, only ADC2=ADC0 events appears. Now understood.