An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. RPCs of BESIII Muon Identifier BESIII and muon identifier R&D Mass production Installation Zhang QingminAdvisor:Zhang Jiawen

  2. The BESIII Detector Magnet yoke and muonidentifier SC magnet Itis the outmost subsystem of the BESIII detector to measure the muons, consisting of muon counters and hadron absorbers, the muon’s position and trajectory can be obtained through multi-layers measurements. TOF Be beam pipe MDC CsI calorimeter To obtain a large solid angle coverage, the muon counters splitted off into two parts, namely barrel and endcap. Barrel has 9 layers, its inner radius is 1700mm and outer radius 2620mm. Endcap has 8 layers.

  3. Muon identifier ---- Barrel & Endcap The structure of the endcap sketch map The size of each layer of the barrel part RPC

  4. R&D of RPC The prototype RPCs for the BESIII muon identifier were constructed by using resistive electrodes made from a special type of phenolic resin developed by us. The surface quality of these plates is improved compared to other bakelite plates that have been used to construct RPCs elsewhere. A method for adjusting the resistivity of these plates was also developed. Extensive studies were conducted by using a number of prototype RPCs in the last several years. Tests have shown prototype RPCs made by using our resistive plates without linseed oil treatment can achieve the level of performance comparable to RPCs with linseed oil treated bakelite or resistive glass electrodes. All of the follow experiments are in streamer mode.

  5. Oscilloscope traces of 100 triggered cosmic ray muons registered in a RPC prototype at 8 kV. The average signal size from a pickup electrode is about 400 mV with a 50 Ω termination. No secondary streamers were recorded secondary streamers R&D----Amplitude vs. HV 450mv

  6. R&D----Eff. And Cnt. VS. HV Efficiencies and singles counting rates versus the high voltage up to 12 kV. This plot shows the behavior of the prototype RPC under extreme high voltages. The gas mixture used was Ar(argon) :C2F4H2 (Freon):C4H10 (Iso-butane)= 50:42:8.

  7. R&D ---- prototype performance 1.18 0.044 Efficiency Plateau: 96-98% ~2KV

  8. other experiments neutron irradiation Max: 98.8% neutron irradiation Beam test Average: 97.2% Min: 95.3% R&D---- long-term stability

  9. R&D----Threshold Efficiencies versus high voltage for different discrimination thresholds Singles counting rates versus high voltage for different discrimination thresholds

  10. R&D ----Different gas mixture

  11. R&D----Temperature The efficiency and counting rate versus temperature. Efficiency curve will shift to left side at high temperatures. And the counting rate will increase exponent with temperature.

  12. R&D---- Different Resistivity

  13. Gas vapor test

  14. Total dose:106rad Efficiency: 1% ; 96% Cnt rate: 0.18Hz/cm2 Darkcurrent: 250% more than 1.5μA/m2 Revisiontime: 20days R&D---- Neutron irradiation

  15. R&D----Electron Irradiation No obvious change !

  16. R&D----γIrradiation ( Co60 )

  17. Mass production The RPC production for the BESIII muon identifier has started in middle of 2004and finished in the early of 2005. The average area for the endcap RPC is 1.3m2, barrel RPC 1.4m2. The maximum area for the endcap RPC is 1.6m2, barrel RPC 2.0m2. There are 978 RPCs and the area is about 1300m2 totally. Each bare chamber is tested to ensure their performance is meet the requirement of the muon identifier before them assembled in the module, and all of modules are tested using cosmic rays before them installed on the BESIII. // Maximum RPC we can make is 1.2mx2.4m. //

  18. Mass production----Bare chamber The worker are facturing the bare chambers!

  19. Mass production---- Bare chamber test Test surrounding

  20. 0.07- 0.1 0.095- 0.11 HV: 7- 8Kv; Eff.>95% More than 97% Eff.>90% More than 35% Eff.>95% More than 95% cnt.<0.6 counting rate (Hz/cm2) Amount: 130RPCs efficiency 0.08- 0.14 Efficiency at 7kV 0.07- 0.1 Counting Rate at 7kV (Hz/cm2) HV7-8Kv,Eff 90%-95% The performance of the RPC that just produced No training

  21. Endcap 7.5Kv Min. 83.5% Max. 98.5% Aver.93.46% Barrel 7.5Kv Min. 85.6% Max. 99.02% Aver.95.39% Endcap 8.0Kv Min. 89.97% Max. 98.7% Aver.94.25% Barrel 8.0Kv Min. 90.38% Max. 99.2% Aver.96.4% Mass production---- Bare chamber test result ---- efficiency Training time : 1 - 3days; endcap 320RPCs, barrel 590RPCs

  22. Endcap 7.5Kv Min. 0.038 Max. 0.598 Aver.0.210 Barrel 7.5Kv Min. 0.016 Max. 0.599 Aver.0.095 Endcap 8.0Kv Min. 0.043 Max. 0.960 Aver.0.255 Barrel 8.0Kv Min. 0.022 Max. 0.872 Aver.0.130 Mass production----Bare chamber test result ---- counting rate Training time : 1 - 3days; endcap 320RPCs, barrel 590RPCs

  23. Endcap 7.5Kv Aver. 3.47 Barrel 7.5Kv Aver. 1.605 Barrel 8.0Kv Aver. 2.415 Endcap 8.0Kv Aver. 4.07 Mass production---- Bare chamber test result ---- dark current Training time : 1 - 3days; endcap 320RPCs, barrel 590RPCs

  24. Bare chamber performance requirements • Temperature : 20±2ºC; Humidity≤50%; Ar:F134A:Iso=50:42:8 • Reaching the efficiency plateau as the high voltage reaches 7.0kv and In the middle of the efficiency plateau(8.0KV) • Eff > 90%; Cnt. < 0.8Hz/cm2; Cur. < 10μA/m2 • The resistivity range : 8x1011~5x1012Ohm • So 92% RPCs of endcap up to grade and 99% RPCs of barrel up to grade. NOTE: All of the previous performance is signal RPC’s.

  25. Mass production----Module The worker are assembling the modules!

  26. Mass production ---- Module test Test result of an endcap module One example of the cosmic ray test result: The plot size: 35mm*35mm; Average efficiency: 0.94 Spatial resolution: 14.6mm

  27. The efficiency and current distribution of all 64 endcap modules: Note that the average efficiency is underestimated, because the efficiency at the edge is pull down by boundary effect. Test temperature: 22-25℃ Mean 0.91 Mean 2.7 μA/m2 …after assembling - endcap

  28. Total efficiency and current of 64 endcap RPC modules after installation. Test temperature: 20-22℃ Test Result after installation - endcap Mean 0.95 Mean 1.8μA/m2

  29. …barrel Module size: 3800mm*1640mm Strip length: 3800mm Strip width: 33mm Average strip efficiency: 0.99 Spatial resolution: 14.2mm

  30. Total efficiency and current distribution of 72 barrel modules: Average efficiency higher than that of endcap modules, while dark current smaller than endcap modules. Test temperature: 22-25℃ Mean 0.98 Mean 1.1μA/m2 …after assembling - barrel Barrel After installation have not been tested!

  31. Installation

  32. Installation All except three modules have been installed! After installing ,the endcap are being tested!

  33. Summary • The RPCs making with new bakelite plates that we developed have good surface quality(~200nm), it can meet with different RPC detector requirement. • The bulk resistivity range of bakelite plates is 109~1014Ω·cm. • The RPC avoid the problem of linseed oil and glass RPC • The RPCs have higher efficiency, lower counting rate and dark current, and good long-term stability . The end THANKS