Comparison of Microwave and Mechanical Measurements of FXA-001 Structure.

Comparison of Microwave and Mechanical Measurements of FXA-001 Structure. FXA-001 Structure Single cell measurements Mechanical measurements Setup for bead-pull measurements Plunger and bead-pull measurements Tuning of FXA-001 Summary.

Download Presentation

Comparison of Microwave and Mechanical Measurements of FXA-001 Structure.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Comparison of Microwave and Mechanical Measurements of FXA-001 Structure. • FXA-001 Structure • Single cell measurements • Mechanical measurements • Setup for bead-pull measurements • Plunger and bead-pull measurements • Tuning of FXA-001 • Summary Tug Arkan, Harry Carter, Dave Finley, Ivan Gonin, Temir Khabibouline, Gregg Kobliska, Gennady Romanov, Nikolay Solyak, Ding Sun, Evgeni Borissov. Nikolay Solyak Structures Workshop@SLAC

  2. FXA-001 Structure. It is the first X-band (11.424 GHz) RF structure built, measured and tuned at FNAL. It is tapered structure about 20 cm long, made of 20+3 cells. It is named FXA-001. Note the cells, couplers, rf flanges, water pipes, beam tubes. It took a little more than nine months. We have our first X-Band structure. Nikolay Solyak Structures Workshop@SLAC

  3. FXA-001 is made according to SLAC’s design of T20VG5 for NLC High Gradient Testing. • 45 mm RF disks were fabricated by two different vendors LaVezzi Inc. (3 sets) and Medco Inc. (2 sets). • An outside vendor fabricated the Input and Output RF Couplers. Contour Manufacturing and Metrology Inc. (CMM) is a diamond turning ultra precision machine shop and it is located at Troy, MI. Cell and coupler production. Nikolay Solyak Structures Workshop@SLAC

  4. FXA-001 Disk Specifications D=8.74268mm Cell dimensions: 2a, 2b, t (iris thickness), D (cell length) and R=t/2 (round ris). Nominal Frequency = 11.417 GHz Nikolay Solyak Structures Workshop@SLAC

  5. RF measurements for LaVezzi and MedCo disks LaVezzi disks MedCo disks Nikolay Solyak Structures Workshop@SLAC

  6. For MedCodiscs the random scattering of frequencies were found to be rather small, but some systematic error for “0”-like mode of approximately 20 MHz exists in both sets. To evaluate which dimension is responsible for this systematic error a linear approximation of the set-up frequencies has been used. Assuming that the errors a, b are small, the frequency shifts for both modes can be expressed as 2a, 2b deviations for LaVezzi and MedCo disks Frequency derivations are well known from cal- culation. So,errors a and b can be found. LaVezzi discs have smaller systematic errors and bigger random errors. But working frequency higher than 11.424 GHz Nikolay Solyak Structures Workshop@SLAC

  7. Errors in bead pull measurements Wave, reflecting from cell vs. cell number at 11.400 GHz Error in frequency measurement for FXA-001 is about  0.6 MHz Nikolay Solyak Structures Workshop@SLAC

  8. Mechanical measurements Cordax Coordinate Measuring Machine in QC Laboratory OGP Optical CMM Nikolay Solyak Structures Workshop@SLAC

  9. Iris Profile Measurements Vendor #1 (LaVezzi) looks “good” here. … but would not pass single disk RF QC due to large disk to disk variations. Vendor #2 (MedCo) looks “not good” here. … but single disk RF QC showed very good disk to disk control. Nikolay Solyak Structures Workshop@SLAC

  10. Frequency Calculation with MedCo real Iris Profile Freq. nominal = 11.417 GHz actual = 11.394 GHz Nikolay Solyak Structures Workshop@SLAC

  11. Frequency Calculation with MedCo iris Profile Nikolay Solyak Structures Workshop@SLAC

  12. RF measurements on FXA-001 Network analyzer. Bead pull support. Pulley. Data acquisition and data analysis is controlled by computer. Bead pull setup in RF Factory Clean Room A Nikolay Solyak Structures Workshop@SLAC

  13. RF Measurements on FXA-001(G.Romanov, D.Sun, I.Gonin, T.Khabiboulline) Bead Pull Principle • A network analyzer puts an rf wave into the structure composed of cells and couplers. Some of the wave is transmitted, some is reflected, and the reflected power measured and analyzed. • A metal “bead” (shown as “needle” in the figure) is pulled along the length of the structure and disturbs the rf wave. • The analysis yields the amplitude and phase of the wave. From PAC95 paper on DESY S-Band setup Nikolay Solyak Structures Workshop@SLAC

  14. RF measurements on FXA-001 (1) RF Measurements on FXA-001 Im vs. Re part of reflected rf wave at 11.400 GHz before tuning. Note: You want 11.424 GHz; thus the cells are about 24 MHz low. • The bead is pulled through the structure at a constant speed over about 140 seconds. • Data is taken at constant time intervals. • The data taking window is about 10 msec. Nikolay Solyak Structures Workshop@SLAC

  15. RF Measurements on FXA-001 RF measurements on FXA-001 (2) Amplitude of reflected rf wave at 11.400 GHz before tuning as a function of time. • You want this to be flat - which it isn’t. • This is the same measurement as the previous slide but it is easier to see that every third peak is smaller than the other two. Nikolay Solyak Structures Workshop@SLAC

  16. Tuning of FXA-001 structure Tuning of FXA-001 Nikolay Solyak Structures Workshop@SLAC

  17. RF measurements on FXA-001 Amplitude vs. time after coupler tuning at 11.422 GHz. Nikolay Solyak Structures Workshop@SLAC

  18. Summary • First Accelerating Structure FXA-001 was built, measured and tuned at FNAL • Built RF setups for low-power RF measurements. (RF Factory). • Mechanical and RF QC of discs discovered noticeable errors in disk dimensions, made by vendors. This errors will be fixed in next structures. • Automation of RF measurements. Data acquisition and data analyzing is controlled by computer. • FXA-001 structure was measured and tuned to working frequency 11.424 GHz. Nikolay Solyak Structures Workshop@SLAC