1 / 14

Experience with Monitoring & Reporting in the EU-ETS 12 May 2005

Explore practical solutions for CO2 monitoring in the European glass industry. Learn about sources, monitoring methods, and verification practices. Discover industry suggestions for efficient monitoring and reporting. Consider harmonizing monitoring plans at the EU level.

Download Presentation

Experience with Monitoring & Reporting in the EU-ETS 12 May 2005

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Experience with Monitoring & Reporting in the EU-ETS12 May 2005 Glass Technical session VII Guy Tackels CPIV 89, Avenue Louise (Box2)B - 1050  Brussels Phone +32 2 538 44 46 Fax +32 2 537 84 69www.cpivglass.be

  2. European Glass Industry • Very diverse (Flat glass, Container, Special glass, Tableware, Fibreglass, etc…) • Size from 5.000 t CO2/year up to more 400.000 t/y for an installation • In France, on 50 installations, 30% are above 100.000 t/y and 40% are below 50.000 t/y • Glass quality is essential. This requires a very stable process, running continuously.

  3. Glass industry • Two main sources for CO2 : • Combustion : HFO and NG • Process emissions coming from the raw materials (carbonates decomposition) • Other sources are generally of minor importance : Diesel oil, SO2 scrubbing, … ( with sometime de minimis approach applicable)

  4. Carbonates Acid gases scrubbing CO2 Sales

  5. Main remarks about the questionnaire • Definition of a « Source », boundaries • Definition of « unreasonably high cost » • Difficult to comment a document not yet used in practice • In annex IX (Glass) Method B : alkali oxides is not recommended in practice • Tiers level not always easy to prove • Pragmatic attitude required from the verification body. Important to take into account verification costs

  6. Main remarks about the questionnaire • Continuous monitoring unrealistic • Do not add a new system when others are already existing (UK CCA, WBCSD/WRI adapted to glass industry, …) Discussion with industry will be helpful. • Level playing field : Same glass factory could be treated differently in different MS • Etc…

  7. CO2 monitoring in the glass industry • CO2 from combustion • CO2 from process : decomposition of carbonates from raw materials (mainly sodium carbonates, calcium carbonates and dolomite) What is the simplest solution? • For monitoring? • For verification?

  8. Some suggestions from the glass industry • The combustion products used on the site are mainly • Heavy fuel oil • Natural gas • The best and more accurate data are coming from the bills from the suppliers (including stock corrections) • For raw materials, same conclusion : the bills from the suppliers give the best accurate results

  9. Data used for commercial purpose are quite sufficient to monitor CO2 • Monitoring plan must be based on bills • Definition of the source must be clarified • No sub-metering required to monitor the total emission of an installation • The verification will be simplified and total cost will be kept at reasonable level

  10. A last suggestion… • Monitoring plans should be harmonised at EU level. • Why not to work on a single document • A calculation tool developed by the CPIV could be a good starting point. This tool was adapted from the WBCSD/WRI reporting system

  11. THANK YOU!

More Related