MRI Artefakter

Introduksjon Fase feilmapping Aliasing/ wrap around Kjemisk skift artefakt Kjemisk missregistrering Trunkasjonsartifakt. Magnetisk susceptibilitets artefakt Zipper artefakt Shading artefakts Pasient bevege Cross exicitation og cross talk. MRI Artefakter. Fase mismapping.

rupali
Download Presentation

MRI Artefakter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introduksjon Fase feilmapping Aliasing/ wrap around Kjemisk skift artefakt Kjemisk missregistrering Trunkasjonsartifakt Magnetisk susceptibilitets artefakt Zipper artefakt Shading artefakts Pasient bevege Cross exicitation og cross talk MRI Artefakter

  2. Fase mismapping • Fase mismapping skapes ved at anatomi beveger seg langs en gradient under ett MR-opptak • Ghosting oppstår ved at en struktur beveger seg under sekvensen. Eks. brystvegg under respirasjon.

  3. Ghosting Westbrook C., Kaut C. (1998), MRI in Practice Tids delay mellom fase enkoding og readout Hvordan ghosting oppstår

  4. Ghosting Axial image av abdomen. Westbrook C., Kaut C. (1998), MRI in Practice

  5. Hvordan redusere ghosting • Total eliminasjon umulig. • Ghosting forekommer bare i faseretningen.Kan skifte fase og frekvensretning slik at artefaktet ikke går gjennom de strukturer en ønsker å avbilde. • Pre-saturasjon. • Respiratory compensation. • EKG-trigging • GMR (for flow)

  6. Westbrook C., Kaut C. (1998), MRI in Practice bytte fase og frekvens retning presaturering (hindrer artefakt fra svelgebevegelse)

  7. Respiratory compensation Westbrook C., Kaut C. (1998), MRI in Practice Kompenserer ved å legge faselinjer med stort faseskift der respiratorisk bevegelse er minst, og omvendt. Ghosting øker med kraftig fasegradient

  8. Respiratory compensation Westbrook C., Kaut C. (1998), MRI in Practice

  9. EKG trigging Uten... Med... Westbrook C., Kaut C. (1998), MRI in Practice

  10. Aliasing / wrap around Westbrook C., Kaut C. (1998), MRI in Practice Både i frekvens og fase retning.

  11. Anti aliasing Frekvens aksen Fase aksen Westbrook C., Kaut C. (1998), MRI in Practice

  12. Fase aliasing Westbrook C., Kaut C. (1998), MRI in Practice Med og uten fase-antialiasing.

  13. Kjemisk skift artefakt Westbrook C., Kaut C. (1998), MRI in Practice