An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. NSTX TF Flag JointDesign ReviewSUMMARYC Neumeyer8/7/3

  2. Topics • Performance • Design Margins • Design Improvement Summary • Conclusions

  3. PERFORMANCE FEA Element Pressures and Resistivities Red cells > 1mW-in2

  4. Temperatures Well Below Limit of 120oC Max Temperature of 94oC Occurs Just After EOFT • Tflat = 0.7sec (vs. 0.6 req’t) • Bolt Holes not exactly modeled (+10oC) • OH constant at max current (-TBDoC) • Insignificant change from constant resistivity simulation Contact Region

  5. DESIGN MARGIN METHODOLOGY • State Safety Factor against Yield (as applicable) and against Failure • Flag bolts, Collar bolts, Box bolts • Compare load to published material data for yield and ultimate tensile • Threaded inserts and Shear Shoe bolts • Compare load to yield and failure data from pullout tests • Failure data based on 3s statistics • Yield based on stress/strain test curves , average yield/failure ratio • Wet lay-up • Compare load to failure data from shear tests at 1ksi compression • Failure data based on 3s statistics • FEA-derived loads • Use worst load from all 4 “nominal” cases: m =0.2,0.4, T= SOFT,EOFT

  6. FEA peak/avg = 1.65 SHEAR TEST DATA INTERPRETATION

  7. TEST DATA

  8. DESIGN MARGINS

  9. DESIGN IMPROVEMENTS

  10. All defects contributing to original failure have been addressed

  11. CONCLUSIONS • New Design Corrects All Defects Associated with Original Design • New Design Has Sufficient Margins at 6kG • Follow-on Activities Will Increase Confidence • Mechanical Prototype Testing • Electrical Prototype Testing • Instrumentation During Commissioning and Operations • - voltage drop (200A maintenance and real-time) system • - other (temperature, strain, displacement)