1 / 18

Optical Alignment System for Muon Tracker

Optical Alignment System for Muon Tracker. Atsushi Taketani, RIKEN/RIKEN Brookhaven Research Center Hiroki Kanou , Takashi Watanabe , Nobuyuki Kamihara, and Takuma Horaguchi Tokyo Institute of Technology. Hardware Learned from RUN3/4 Upgrade Plan and Summary. Optical Alignment Sytem.

Download Presentation

Optical Alignment System for Muon Tracker

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Optical Alignment System for Muon Tracker Atsushi Taketani, RIKEN/RIKEN Brookhaven Research Center Hiroki Kanou, Takashi Watanabe, Nobuyuki Kamihara, and Takuma Horaguchi Tokyo Institute of Technology Hardware Learned from RUN3/4 Upgrade Plan and Summary

  2. Optical Alignment Sytem • Configuration • Light Source(station1) •  ・Single 150W Halogen light per •  ・Optical fiber to station1 • Focusing lens(station2) •  ・1cm convex lens • CCD camera (station3) • effective area 8.8×6.6 mm • Number of pixels 768× 498 • Pixel size 11.0×13.0 mm Total 7optics/Octant * 8 Octant/Arm * 2Arm = 112

  3. Data flow CCD Camera Getting spot image ・Taking CCD camera image each 30 min. ・Making light intensity histogram for each X and Y projection. DAQ PC ・Fit histogram and measure peak position Online PC

  4. Position correction of Muon Tracking Chamber 1.Measurement of peak position of light image. 2.Make a model of motion of each Octant with parameters. 3.Position correction 4.Evaluation of correction. Done by Takashi Watanabe as Master Thesis work

  5. Measurement of peak psotion Sharp image Out focus Image X projection X projection Y projection Brightness Brightness Y projection gauss fit pixel pixel window fit

  6. Long term movement North octant4 CCD4 y direction x direction micron micron 300micron 100micron Long Term movement:50~300 micron meter on single CCD camera

  7. ( ) ( ) ( ) xi yi zi DX DY DZ + fi =  Rot(fx, fy,fz) Rotation Displacement in PHENIX Position on Octant ( ) xi-fz yi+ DX fz xi+ yi+ DY Model of movement ~ x0i+ dxi y0i+ dyi = ( ) xi :Image position S = Sum | fi- xi | 2 Center of gravity of camera on octant Peak position in camera = Sum{(-fz y0i + DX - dxi)2+ (fz x0i+ DY - dyi)2 Movement Model without expansion Consider half octant as rigid body Look at the movement on X and Y Ignore rotation along X and Y axis Minimize S with rotation and displacement

  8. ( ) ( ) ( ) DX DY DZ xi yi zi fi =  Rot(fx,fy,fz) (1+a) + (1+a)xi - fz yi + DX fz xi + (1+a)yi +DY ( ) :Movement of Model fi= Movement model with expansion Dr = a(t)r: Isotropic expansion ( ) x0i + dxi y0i + dyi :Image position xi = Minimize S S = Sum |fi - xi|2 = Sum {(ax0i - fz y0i + DX - dxi)2 + (fz x0i + ax0i + DY - dyi)2}

  9. Camera Combination ・Use North Arm, octant4, CCD4、5、6、7 ・Evaluate by comparing different camera configuration

  10. Correction comparison on Dx 456 and 457 456 and 467 -10 micron -10 micron 0 10 0 10 456 and 567 Correction evaluation Displacement on X : 9~ 27 micron Y : 5~ 24 micron Rotation along Z axis : 4- 15 micro rad Expansion : 2 ~ 15* 10^-6 10 -10 0 micron

  11. Temperature and Magnetic field dependence Magnetic field day C Temp day ・Temperature changes after magnetic field change ・Magnetic field moves chamber mm DX day mm DY day rad fz day a day

  12. RUN4 Data acquisition is not stable. Pay attention by MuTr expert shift or PHENIX shift. Good: good accuracy of peak Recoverable : not good accuracy No Image : No image at all

  13. How to Improve • No Image : Need to access the area inside magnet. -> Not this year. • Recoverable: Take more picture, integrate them and then get sharper image. • Replace DAQ system from GUI operation base to Labview base.

  14. Daq system Labview Video signal Video Capture board Video signal LAN LAN GPIB Linux Windows GPIB-Ether Net Multiplexer CCD Camera (*56) Take pictures, Integration Make projection Change cameras Save data

  15. All of components for prototyping are build at RIKEN Initialize system few msec Check hardware few sec Change camera 50 msec for 1ch Take pictures 110 msec for 1ch, 1 picture Integrate pictures 40 msec for 1ch, 1 picture Make projection 40 msec for 1ch Save to file 20 msec for 1ch Close system few msec Executed 56 times Large contribution Take N pictures for all camera… T = 8.09N + 5.06 + few (sec) (N < 73, T < 10 min.)

  16. Plan and Summary • YoungHiroki will build Labview based system at RIKEN and move it to BNL at Aug. • Looking OASYS will be shift duty. • OASYS analysis data will be implemented in the geometry database and then improve J/PSI mass resolution.

  17. Performance Taking 1000 images from same camera for 30 minutes.

  18. Temperature and Expansion a : expansion day Temp. day

More Related