180 likes | 265 Views
PDs for 1E29 - 8E29 @ 7 TeV. Outline. Results for standard HLT table and PDs definition for 8E29. PD definition (slide 3-4). PD rates (slide 5). Trigger rates (slide 6-8). Problems and strategy for lower lumi (slide 9-13). Estimation for onia triggers @ 8E29 on ppMuX (slide 14-end).
E N D
Outline • Results for standard HLT table and PDs definition for 8E29 • PD definition (slide 3-4) • PD rates (slide 5) • Trigger rates (slide 6-8) • Problems and strategy for lower lumi (slide 9-13) • Estimation for onia triggers @ 8E29 on ppMuX (slide 14-end)
missing HLT_HT100U L1_HTT100 1, 1 missing HLT_BTagMu_Jet10U L1_Mu3QE8_Jet6 1, 1 no L1 available!
HLT_L1MuOpen HLT_MinBiasPixel HLT_ZeroBias HLT_Mu3 HLT_Ele10_LW_L1R HLT_DoublePhoton5_eeRes_L1R HLT_SingleLooseIsoTau20 HLT_Jet30 HLT_IsoMu3
Whit this “standard” trigger table and PD definition we will have problems of too small PDs at low lumi possibilities shown in next slides: 1) merging different PDs at low lumi (switching from one PD definition to another increasing the lumi → review the PDs distribution → change of data taking era) 2) lower the HLT prescales at low lumi
1) which PDs we can merge ? (same as slide 4)
New quarkonia triggers (1) MuMonitor: HLT_L1MuOpen HLT_L1Mu Mu: HLT_Mu3 HLT_Mu5 HLT_Mu9 HLT_IsoMu3 HLT_L2Mu9 HLT_L2Mu11 HLT_L1Mu20 HLT_L1Mu14_L1SingleEG10 HLT_L1Mu14_L1SingleJet6 HLT_L1Mu14_L1ETM30 HLT_DoubleMu0 HLT_DoubleMu3 HLT_L1DoubleMuOpen New singleMu triggers: + HLT_Mu0Track_JPsi + HLT_Mu3Track_JPsi + HLT_Mu5Track_JPsi + HLT_Mu5Track_Ups New doubleMu triggers: + HLT_Mu0_MuOpen + HLT_Mu3_MuOpen + HLT_Mu5_MuOpen + HLT_Mu3_Mu0 All the new quarkonia triggers are NOT prescaled at HLT
New quarkonia triggers: L1 seeds New singleMu triggers: + HLT_Mu0Track_JPsi L1SingleMuOpen || L1SingleMu0 + HLT_Mu3Track_JPsi L1SingleMuOpen || L1SingleMu0 || L1SingleMu3 + HLT_Mu5Track_JPsi L1SingleMu3 + HLT_Mu5Track_Ups L1SingleMu3 useless ?? New doubleMu triggers: All these L1 are not prescaled at 8E29 + HLT_Mu0_MuOpen L1DoubleMuOpen + HLT_Mu3_MuOpen L1DoubleMuOpen + HLT_Mu5_MuOpen L1DoubleMuOpen L1DoubleMuOpen + HLT_Mu3_Mu0
Standard 8E29 with ppMuX 2 M of ppMuX events → only muons PDs have statistics ppMuX underestimate the rate !! +/- 0.1 Hz (was 19.5 in MinBias)
Muon PD with new triggers (8E29, 7 TeV) 2 M of ppMuX events → only muons PDs have statistics +/- 0.1 Hz (was 9.0 Hz without onia triggers)
ppMuX MinBias no onia: 9 Hz 19.5 Hz with onia: 13.8 Hz > 30 Hz We need to separate PD Mu into single and double at ~8E29