1 / 15

QIBA Proposed Phase 1A Project V5.0

QIBA Proposed Phase 1A Project V5.0. QIBA Phantom Subgroup. Outline of proposal. Modified 1A reader study Outstanding issues. Draft 1A: Study objective. Measure intra- and inter reader bias and variability on phantom lesions for: Uni-dimensional size measurement

sidneys
Download Presentation

QIBA Proposed Phase 1A Project V5.0

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. QIBAProposed Phase 1A ProjectV5.0 QIBA Phantom Subgroup N Petrick RSNA QIBA Phantom Group November 13, 2008

  2. Outline of proposal • Modified 1A reader study • Outstanding issues N Petrick RSNA QIBA Phantom Group November 13, 2008

  3. Draft 1A: Study objective • Measure intra- and inter reader bias and variability on phantom lesions for: • Uni-dimensional size measurement • Semi-automated 3D volumetric measure • Compare with fully automated algorithm? Not going to size for specific effect or significance but just report as pilot N Petrick RSNA QIBA Phantom Group November 13, 2008

  4. Draft 1A: Nodule/scan dataset • Nodules (10 attached nodules) • -10 & +100HU • 10, 20 mm spheres • 10 mm ovoid, lobulated, spiculated • Scanner • Philips 16 slice • Exposure (120 kVp): • 100 mAs • Slice thickness (50% overlap) • 0.75 & 5.0 mm slices • Recon kernel • Standard/medium (Still on table: Detail/Lung kernel) • Pitch • 1.2 • 2 repeat scans • 40 segmentations in set Okay 100 mAs okay 0.75 mm slices okay Okay N Petrick RSNA QIBA Phantom Group November 13, 2008

  5. Draft 1A: Study Protocol • Reader: • 6 RadPharm radiologists • Software: • In-house review software (Siemens?) • Semi-automated 3D volume software • Uni-dimensional measure (RESIST) • Which fully automated software? Need to determine this? Wendy will visit RadPharm and provide more info next week. N Petrick RSNA QIBA Phantom Group November 13, 2008

  6. Draft 1A: Study Protocol • Reading session: • Readers read all cases in 2 different reading session • Random ordering • One-dimensional measure • Semi-automated segmentation • Session separated by 3 week? • Include duplicate cases within each read session (1/3-1/2 of cases for intra-reader estimates) • Any time restrictions? • Probably not • Any specific instructions? • Probably not N Petrick RSNA QIBA Phantom Group November 13, 2008

  7. Draft 1A: Analysis Okay • Estimate intra- and inter-reader variability in the different volume estimate • Estimate bias from known truth • Estimate variability • Compare the bias and variability with the different methods N Petrick RSNA QIBA Phantom Group November 13, 2008

  8. Draft 1A: Outstanding issues • Objective-Okay • This is pilot, no sizing will be done • May want to at least look at this to see if we have a reasonable study design • Data collection: Okay • +100 HU (all 1A scanner settings) • Acquired: 10 mm & 20 mm sphere, ovoid, spic, lob • -10 HU (all 1A scanner settings) • Acquired: 10 mm & 20 mm sphere • Missing: 10 mm ovoid, spic, lob (Est: 12/01/08) • 10 mm aspherics okay • 100 mAs okay N Petrick RSNA QIBA Phantom Group November 13, 2008

  9. Draft 1A: Outstanding issues • Readers-Okay • 6 okay (base on expected effect size?) • Software-Open source option is available to use • Need to finalize which software • Contact Bob Ford to discuss • Study Issues • GUI • AVT designed interface? • Standard PACs interface? • How will nodule locations be provided to readers? • Full scans with nodule centers • Extracted ROIs • Can cases be directly uploading into PACs? • How to randomize cases during reading sessions • Data format for segmentations/measurements • Truth/scoring format • ROIs or full scans with lesion marked N Petrick RSNA QIBA Phantom Group November 13, 2008

  10. Draft 1A: Pilot Study • Study protocol • 9 nodules for segmentation • 2 slice thickness • 10 mm -10 HU, sphere, spiculated • 10 mm, +100 HU, lob., ovoid • 20 mm, +100 HU, sphere • 3 nodules with each segm. method • 2 readers • Timeframe • Needs to be determined N Petrick RSNA QIBA Phantom Group November 13, 2008

  11. Draft 1A: Outstanding issues • Statistical • Can we measure intra-reader variance with only 2-4 repeat reads? • What effect size can we distinguish? • Again, may want to explore but this study will only measure as in a pilot N Petrick RSNA QIBA Phantom Group November 13, 2008

  12. Draft 1A: Outstanding issues • Other issues • Need to define QIBA publication policy • Determine research team makeup • Lisa Kinnard & Marios Gavrielides from FDA lab • Other Issues N Petrick RSNA QIBA Phantom Group November 13, 2008

  13. Draft 1A: Submissions • Conferences • ASCO • 5/29-6/2/09 Orlando • Abstract Deadline: 1/6/09 • RSNA • End Nov, 2009, Chicago • Abstract Deadline: 4/15/09 • Journal • NEJM! • Radiology • Oncology journals? N Petrick RSNA QIBA Phantom Group November 13, 2008

  14. Action Items • Rick Avila to follow-up with caBIG AVT group • Rick Avila to lead effort of Lesion Ground Truth subgroup • Reporting Mechanism to be discussed at later date N Petrick RSNA QIBA Phantom Group November 13, 2008

  15. Work Items and workgroup • ?? N Petrick RSNA QIBA Phantom Group November 13, 2008

More Related