An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Status of RAL Studies for Muon Beam • Comparisons with RIKEN Muon facility • Pion Injection • Decay + Muon Extraction • Beam Emittance Tuning & Matching Kevin Tilley , ISIS , RAL

  2. Pion Injection

  3. Performance 50cm Y 0cm X 50cm

  4. Decay Ch + Muon Extn

  5. Poss. Muon Extn Layout 50cm Y 0cm X 50cm 14.46m 18.26m 28.26m 34.46m

  6. Base Beam w/o scatterer Some performance data for above collimated, matched beam from tracing 10^6 pions through TURTLE. Data shown is for muons at entrance to Spectrometer Solenoid. * 9.3 % corresponding to +/- 20Mev/c about mean of p0 = 215Mev/c Collimation this plane

  7. Addition of Scatterer • In order to avoid beam scraping, scatterer placed after all quadrupoles, at entrance to Spectrometer Solenoid. Q. How plan to provide the larger matched emittance’s? • Incoming beam cylindrically symmetric. can be generated, and the beam matching *. conditions can be met by adjusting input beam & changing diffuser x’/y’ 1. Focus Beam with x/y 2. & Matched after passing thru’ required scatterer ! MICE ACCEPTANCE * correction coils not used here.

  8. scatterer simulation results (1) Iteration for xRMS ~ 3.72cm x’RMS ~ 112mrad r ~ 0 AFTER Scatterer Before Scatterer

  9. scatterer simulation results (2) Iteration for xRMS ~ 5.73cm x’RMS ~ 175mrad r ~ 0 AFTER Scatterer Before Scatterer

  10. & magnet availability ! 4 x Q35s. Bore diam = 35.8cm. Lmax/Leff = 1.046 / 0.66m 7 x Q35 half quads  full quads! Also exist other magnets on RAL site (eg. LBs Leff ~ 0.3m but small ap.) Other magnets at other sites? Type 1 NIMROD Dipole (x2 from ex-HEP line)

  11. Summary • Present Pion Injection % compares well with RIKEN • A possible Muon Extraction system described using 3triplet sets. • 2 of above 3triplet sets are available. • Emittance tuning & beam matching scheme described using focussing and changeable scatterer.