An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Preferred Utilities Manufacturing Corp Fuel Oil Handling Systems Fuel System Products Preferred Utilities Mfg. Corp. 31-35 South St. • Danbury • CT www.preferred-mfg.com

  2. Fuel Fill Components Vents AntiSyphon Valve Fire Safety Valves Foot Valves Relief Valves Tank Selector Valves Back Pressure Regulator Valves Strainers Pump Set Components Day Tanks Flow Control Manifolds Tank Gauges Leak Detectors Agenda

  3. Fuel Oil Products

  4. Fuel Management Systems

  5. Level Control Arrangement Emerg. Gen. Day Tank Vent with Rupture Basin Fill Return Supply Suction Pump Main Oil Tank

  6. Fuel Fill Model 1 (Catalog 23, p63) • Spill Containers • Model 1 In Ground Spill Container • Drains oil spilled from delivery disconnect into storage tank • Designed to handle driveway traffic • Removable bellows for easy fuel testing without pavement excavation.

  7. Fuel Fill Model 2 (Catalog 23, p61) • Model 2 In Wall Spill Container • For indoor storage tanks with fill lines to building walls • Standard models from simple box to integrated digital level display and overfill alarming • We can customize many things:A bronze Model 2 was recently installed at Radio City Music Hall to contribute to the building’s décor.

  8. In Wall Spill • We required that all components in the alarm station be of explosion proof construction including the alarm horn, alarm light, silencing push-button and digital remote readout (if required). • Explosion proof components are required for safety and to prevent the ignition of the fuel oil vapors generated from the sun heating the spill container. Catalog 23 Page 61

  9. In-Wall Fill Box with Sign

  10. Level Control Arrangement Emerg. Gen. Day Tank Vent with Rupture Basin Fill Return Supply Suction Pump Main Oil Tank

  11. Vent • Vent Caps & Bricks • Standard Tank Vent Protectors for storage tanks • Conform to Standards for the Installation of Oil Burning Equipment (NFPA No. 31) Vent Cap (Catalog 23, p68)

  12. Vent • Vent Bricks provide a terminal for indoor storage tank vent lines • Standard masonry brick size • Fits 2" & 3" vent lines Vent Brick (Catalog 23, p68)

  13. Level Control Arrangement Vent Emerg. Gen. Day Tank with Rupture Basin Fill Return Supply Suction Pump Main Oil Tank

  14. Anti-Syphon Valves • Patented by Preferred Utilities. • UL Labeled & Listed Catalog 23, p74

  15. Anti-Syphon Valve Manifold

  16. Anti-Syphon Valve • In addition to requiring a UL listed valve we now require a Bronze valve rather than a cast iron • We state the ability of bronze not to crack or fail in a fire condition. • We have also explained the importance of the valve. • It is too important to substitute. • We want to get the sale when we get the system or not. We are the only ones that make a ½ & ¾ version. Catalog 23 Page 74

  17. Anti-Syphon Valves • Used where fuel leaks will result in fuel being syphoned into areas which can cause a dangerous and costly situation • UL Labeled and listed • For No. 2 through No. 6 Oils • 5’, 10’, 15’ or 20” Head Selection • Installed at highest point in piping

  18. Fire Safety Shut-off Valves • Lever Gate Valve • Fully mechanical • Emergency fuel line shut-off is mandated by many codes • Fusible links open at 165F • for pipe ranges 3/4" - 3" • Fusomatic Valve • Replaceable fusible element • Fusible links open at 165F, May be manually opened/closed • for pipes 3/4" or 1" Model 110 with alarm switch (Catalog 23, p72) Fusomatic Valve (Catalog 23, p71)

  19. Type 110 Fire Valve

  20. Foot Valves • Ensures maintenance of pump prime by preventing oil backflow into the tank when pumps are off • Single Poppet • 1/2” to 3” Size • Double Poppet • Double the protection • 1-1/2” or 2” Sizes • Foot Valve Extractor Fitting • Easy Removal and Inspection of Foot Valve

  21. Foot Valves Model 900 (Catalog 23, p77)

  22. Level Control Arrangement Vent Emerg. Gen. Day Tank with Rupture Basin Fill Return Supply Suction Pump Main Oil Tank

  23. Relief Valves • Very important for use on positive displacement pumps • Sizes for 1/2” to 3” • For use with any type oil • Pressure Ranges of 5-35psi, 25-100psi, 75-300psi

  24. Level Control Arrangement Vent Emerg. Gen. Day Tank with Rupture Basin Fill Return Supply Suction Pump Main Oil Tank

  25. Fuel Components • Tank Selector Valves • Replaces confusing array of hand valves • Simple lever operation transfers both supply & return lines from one tank to the other • Designed with no “blind spots” where flow could be blocked to or from the tanks • Threaded or flanged connections available Threaded Connection (Catalog 23, p81)

  26. Back Pressure Regulating Valves • Used in a flow loop to maintain proper pressure for burners. • Type BQ for flow rates up to 390gal/hour • Standard Ranges of 26-75psi or 76-150psi • 1/2” Size • Type V for higher flow rates • Standard Range of 30-150psi • 1” Size

  27. Strainers • Duplex • No flow interruption for routine cleaning • 90° handle movement switches baskets • Handle blocks inadvertent opening of active side • Sizes from 3/4" - 6" • Simplex • Special yoke design for quick cleaning • Large basket • Sizes from 1/2" - 2" Duplex Oil Strainer (Catalog 23, p43)

  28. Pump Sets Components • Multiple pumps share common suction and discharge piping • Most common is duplex set • two 100% pumps, one for backup • control system can monitor flow, start lag pump • Triplex pump sets for large plants • three 50% pumps allow for one spare • two 100% “winter pumps” - one 50% “summer pump”

  29. Pump Set Components Pressure Gauges (Catalog 22 p44) Relief Valve (Catalog 22 p49) Flow Switch Duplex Oil Strainer (Catalog 22 p18) Check Valve Ball Valve Duplex Pump & Motor Assembly (Catalog 22 p13) Compound Pressure Gauge (Catalog 22 p44) Base Assembly with Integrated PS-LDS Leak Detector (Catalog 22 p34) Strainer DP Switch/Gauge

  30. Strainer Close-up

  31. Pump Set Leak Detector

  32. Pump Set Relief Valves

  33. Flow Sensor

  34. Control Counts • Emergency Generator System • Unmanned • Reliability is Critical • Long idle periods • Automatic Suction Line Integrity Checking • Boiler Loop • Manned • Runs continuously

  35. Level Control Arrangement Vent Sol. Valve High Pump stop Pump Start Low Control Panel Rupture Basin Leak Detector Return Containment Supply Containment Leak Detector

  36. Day Tanks • Complete Tank, RuptureBasin, and InstrumentationPackage • Standard & Custom Sizes • Standard: 20-620 Gallons (UL Approved) • Custom: up to 2,000 Gallons • Tank/Rupture BasinAssemblies 290 Gal orLess are Doorway Accessible • UL Approved

  37. Flow Control Manifold

  38. Loop System Arrangement Vacuum Breaker Level Switch P Header Low Switch Pressure Switch Control Panel Return Supply Multiple Gen.

  39. Tank Gauging Arrangement 3150 Control Panel Main Oil Tank Fill

  40. Tank Gauge • D3 Tank Gauge • Single Tank Applications • Wire Float Available for Limited Tank Clearance • Standard 4-20 mA output D3 (Catalog 23, p45)

  41. D5 Tank Gauge Monitoring Up to 50 Tank Levels, Discriminating Leaks or Temperatures

  42. Wire Float Level Sensor • Requires only 14 Inches of Head Room • Reads tanks 36 to 145 inches Tall • Buna-N Float • Requires only a 4 inch 125# Flange • Easy to Install and Calibrate • Can Be Installed in an Empty or Full Tank • Intrinsically Safe

  43. Wire Float Level Sensor

  44. Day Tank Level Sensor

  45. Tank Gauges • Digital Level Readout in Inches and Gallons • Alarm Silence, Test, and Alarm Recall Push-buttons • Analog Output for Remote Display of Level • Interface to Leak Detectors • Displays H20 for Water Leak (Outer Wall) • Displays OIL for Oil Leak (Inner Wall) • Low and Overfill Alarm Relays

  46. Leak Detection • Factory Mutual Approved • Intrinsically Safe • Monitors for both Oil and Water • Three Detectors per Tank Gauge • Manual Testing of Unit • Completely Potted for Long Life • Fail Safe Circuitry

  47. Leak Sensor Test Modules

  48. Interstitial Space Leak Sensor

  49. Floor Leak Detector

  50. Leak Sensor