180 likes | 379 Views
Active Noise Control of Small Axial Cooling Fans. Brian B. Monson, Scott D. Sommerfeldt, Connor Duke Department of Physics and Astronomy Brigham Young University 147th Meeting of the Acoustical Society of America New York, New York May 25th, 2004. Overview. Introduction and Background
E N D
Active Noise Controlof Small Axial Cooling Fans Brian B. Monson, Scott D. Sommerfeldt, Connor Duke Department of Physics and Astronomy Brigham Young University 147th Meeting of the Acoustical Society of America New York, New York May 25th, 2004
Overview • Introduction and Background • Experimental Apparatus • Theoretical Modeling • Experimental Results • Conclusions
Active Noise Control • Wave Superposition (destructive interference) pT(p) = p1(p) + p2(p) ≈ 0 • Source Coupling (modified radiation impedance) Z1 = Z11 + Z12 Z2 = Z22 + Z21
Fan Noise Spectrum • Harmonically related tones superimposed on a broadband spectrum (tones are dominant) • Fundamental: blade passage frequency (BPF)
Cooling Fan Control System Developed by Gee, Sommerfeldt
Statement of Problem Due to industry constraints, the previous fan ANC system developed is not optimized for a real world setting. Need a compact system to comply with increasing efforts to decrease the size of electronic office equipment (e.g. desktop computers).
Cooling Fan Control System • Previous System • 80 mm fan • 32 mm loudspeakers • 370 Hz BPF • Modifications • 60 mm fan • 20 mm loudspeakers • 600 Hz BPF • Increase fan speed
On-axis Comparison • 80 mm vs. 60 mm broadband (on axis, non-calibrated, d = 1 m)
Control loudspeakers Fan Theoretical Modeling
Theoretical Modeling Optimum minimization of radiated power Nelson, Curtis, Elliott, Bullmore
15° 18° Global Measurements
Global Comparison Mean-square pressure reduction (MPR)
Conclusions • Noise reduction does not yet achieve theoretical ideal predicted by Nelson et al., particularly with BPF • Compact system, while remaining less obtrusive, is able to achieve as good of global noise control performance as previous system on first three harmonics • Replacement of 80 mm fan with 60 mm fan and ANC system feasible
Future Work • Optimize loudspeaker enclosures for better low frequency response (including THD analysis) • Examine and compare airflow output of fan with and without control • Analyze control performance with increased 60 mm fan speed
Acknowledgements • Kent Gee, PSU • Benjamin Faber, BYU • Lance Locey, BYU • BYU Acoustics Research Group