Table of contents Chassis & Commons 200G Solutions 100G Solutions 8G / 10G /16G Solutions <10G Solutions Amplifiers • EDFA • RAMAN Power Management OADM/ROADM Filters (Mux/Demux) • DWDM • CWDM • Rack Mount Dispersion Compensation Optical Protection Switch
7HU Chassis • 7RU Shelf(MS430504M) • 311 mm | 12.2 inches (H) • 442 mm | 17.4 inches (W) • 264 mm | 10.4 inches (D) • 11.2 kg | 24.7 lbs • 20 generic PM (Pluggable Modules) slots • Any slot hosts any card • Slot 0 used for management card • Continuously upgradable • No backplane limitations preventing new module deployment—200G today, 400G tomorrow in same chassis
7HU Chassis - Mechanicals • Two -48V power supplies connectors • 76 W typical without PMs in generic slots • 1000W max with PMs • AC power via external rectifier (orderable through MICROSENS) • One management card (MS430520M-B) • One FAN unit with six fans • One dust filter • One optical fiber guide panel • Operating temperature • 0°C +50°C
2HU Chassis • 2RU Shelf (MS430501M/MS430503M) • 87 mm | 3.4 inches (H) • 442 mm | 17.4 inches (W) • 240 mm | 9.5 inchess (D) • 6.1 kg | 13.4 lbs • Pluggable 85-265 VAC & -40.8 to -57.6 DC power options • 6 generic PM (Pluggable Modules) slots • Any slot hosts any card • Continuously upgradable • No backplane limitations preventing new module deployment—2x200G today, 2x400G tomorrow in same chassis
2HU Chassis - Mechanicals • NEBS compliant • One management card (MS430520M-B) • One FAN unit with three fans • Hosts three separate fans, each of which generates a fan failure signal in event no rotation • One dust filter • One optical fiber guide panel • Operating temperature • 0°C +50°C (standard version) • -40°C to +65°C (ETR version) • DC or AC option • 120 W typical without PMs in generic slots • 500W max with PMs • MS430501M input power range • Minimum: -40.8V • Maximum: -57.6V • MS430503M input power range: • Minimum: 85 VAC • Maximum: 265 VAC
2HU Chassis ETR • 2RU Shelf(MS430501MX) • 87 mm | 3.4 inches (H) • 442 mm | 17.4 inches (W) • 240 mm | 9.5 inchess (D) • 6.1 kg | 13.4 lbs • 6 generic PM (Pluggable Modules) slots • Any slot hosts any card • Continuously upgradable • No backplane limitations preventing new module deployment—200G today, 400G tomorrow in same chassis • Pluggable 85-265 VAC & -40.8 to -57.6 DC power options • -40°C to +65°C operating temperature range • Requires MS430520MX-B
Management Module MS430520M-B • Hosts the SNMP agent • Hosts the embedded web based http craft terminal • Hosts the console port giving access to the CLI • Provides three (3) external Ethernet interfaces through an internal Ethernet switch. • Provides dedicated interfaces to PM slots and FAN slot. • Provides the interface between the SNMP agent and the PM generic slots for managing the equipped PMs and the FAN unit • ETR version is operational from -40°C to +65°C • Compatible with -48V, +24V • Processor: 32 bit, 1.1 GHz • RAM memory: 512 Mbytes • Flash memory: 512 Mbytes • Operating System: Linux
FAN Units • FAN Unit 1 • For 7HU Chassis • 6 fans per module • Hosts two power converters—main & protection • FAN Unit 2 • For 2HU Chassis • 3 fans per module • Hosts one power converter per fan—main only
External Power Supplies • 1RU chassis containing dual power converters from 110/240 VAC to four -48VDC • Two 110/240VAC power inputs • 1 main and 1 protect • Eight -48VDC power outputs • 4 main and 4 protect • Max. power supply • MS430518M: 300W • MS430518MHC: 1000W MS430518M MS430518MHC
Flex Rate 200G Muxponder • Provides 400G of throughput capacity • Built-in VOA allows the operator to remotely select the output power level anywhere from +3 dBm to -20 dBm • Software selectable line side modulation —DP-QPSK or 16QAM • Multi-protocol support • Compatible with multiple channel spacings—both on-grid and off-grid • Power consumption : 150W (incl. optics) • Operating Temperature 0°C to +50°C • Availableoption for SFW MS430947M MS430948M • Line Side • Integrated selectable modulation format & line rate • 200G DP-16QAM • 100G DP-QPSK • Proprietary framing • 2xOTU4 into proprietary frame • G.709 & SD FEC • OSNR • 200G: 21 dB —1000 Km • 100G: 11.5 dB—10 000 Km • PMD: 30 ps • Transmit Power: +3 to -20 dBm • Receive Power : • 200G: -9 to -19 dBm • 100G: -5 to -18 dBm • Terminal & facility loopback • Tunable C-band • Client Side • 20 x SFP+ pluggable • 10GbE, 8G/10G FC, OC-192/STM-64 and OTU2/OTU2e protocols • Uses standard patchcord • Terminal & facility loopback
Single slot Flex Rate 200G Muxponder • Optimized version of Flex coherent 200G Muxponder • 1 slot module supporting 100G and 200G line • Software selectable line side modulation —DP-QPSK or 16QAM • Compatible with multiple channel spacings—both on-grid and off-grid • Power consumption : 60W (incl. optics) • Operating Temperature 0°C to +50°C • Dual fiber (MS430943M) and simplexfiber version available (MS430944M) • Airflowcardisneeded in case of 7HU chassis MS430943M • Line Side • Integrated selectable modulation format & line rate • 200G DP-16QAM • 100G DP-QPSK • Proprietary framing • 2xOTU4 into proprietary frame • G.709 & SD FEC • OSNR • 200G: 21 dB —1000 Km • 100G: 12.5 dB—10 000 Km • PMD: 30 ps • Transmit Power: +3 to -25dBm for MS430944M and typ. 0dBm for MS430943M • Receive Power : • -5 to -25 dBm • Terminal & facility loopback • Tunable C-band • Client Side • 2 x QSFP28 pluggable • 100GbE clientor OTU4
100G Aggregation card • 10x 10G to 100G aggregation module • 10G SFP+ client ports • 100G QSFP28 line port • Line port of MS430945M cascaded on client port of MS430943M module using specific Passive cable • Multiprotocol support on the 10G client side • 8GFC, 10GbE, STM64, OTU2(e), 10GFC, 16GFC • 40G version available in Q3 2018 MS430945M • Line Side • 1x QSFP28 • OTU4 Line interface • Client Side • 10 x SFP+ pluggable • 10G Multirate
100G Aggregation card - cascading MultiRate (SFP+ clients) Specificopticalpassivecable 2x 100G QSFP28client (100GbE or OTU4): 1 slot solution in 2HU Chassis 1x100G client and 10x10G client (8G/10G/16GFC): 3 slots solution in 2HU Chassis 20x10G client (8G/10G/16GFC): 5 slots solution in 2HU Chassis • 8G, 10G,16G Fibre Channel • 10G Ethernet • 10G SDH / SONET • 10G OTN MS430945M • Single Wavelength • 100G λ or • 200G λ • Single or Dual Fiber MS430943M
100G Aggregation with Encryption • 1x100GbE or 10x10G to OTU4 rate encrypted Line • GCM-AES-256 encryption (Advanced Encryption Scheme) • ECDH Key exchange mechanism (Diffie-Hellman) • Same 10G multiprotocol configuration as 100G Aggregationcard (MS430945M) • Whole 10x10G multiplex being encrypted all together • 40G version available in Q3 2018 MS430961M • Line Side • 1x QSFP28 • OTU4 Line interface • Encrypted • Client Side • 10 x SFP+ pluggableor QSFP28 • 10G Multirate • 100GBE or OTU4
100G Aggregation card - cascading MultiRate (SFP+ clients) EncryptedOTU4 2x 100G QSFP28client (100GbE or OTU4): 1 slot solution in 2HU Chassis 1x100G client and 10x10G client (8G/10G/16GFC): 3 slots solution in 2HU Chassis 20x10G client (8G/10G/16GFC): 5 slots solution in 2HU Chassis • 8G, 10G,16G Fibre Channel • 10G Ethernet • 10G SDH / SONET • 10G OTN • 100G MS430961M • Single Wavelength • 100G λ or • 200G λ • Single or Dual Fiber MS430943M
100G OTN Transponder • Line Side • 1 x CFP pluggable • B&W LR4 or coherent WDM • Terminal and facility loopbacks • 100G OTN transponder with 1x100GbE client and OTU4 line side • OTU4 line can be switched through any standards-based OTN mesh network • Assured interoperability in multi-vendor environments — fully G.709 compliant • Economical CFP interfaces for client and line side • 3-slot pluggable module • 2 x 200G modules in MS430501M / 400G in 2RU • 6 x 200G modules in MS430504M / 1.2T in 7RU • Power consumption : 90W (incl. coherent optics) / 75W (incl. LR4 optics) • Operating Temperature 0°C to +50°C MS430913M • Client Side • 1 x CFP pluggable • 100GbE client support • RMON on 100GbE input & output • Terminal & facility loopback
100G OTN Muxponder • Line Side • 1 x CFP pluggable • B&W LR4 or coherent WDM • Terminal & facility loopbacks • 100G Coherent Metro Access Muxponder w/ 10G aggregation • Data center interconnection & metro transport applications • 3-slot pluggable module • 200G in 2RU • 600G in 7RU • Power consumption : 115W (incl. optics) • Operating Temperature 0°C to +50°C MS430914M • Client Side • 10 x SFP+ pluggable • 10GbE client • RMON on 10GbE input • Terminal & facility loopback
Rack Mount 100G Transponder (MXP100) • 100G Ultra-Long Haul Transponder • Transports 1x100GbE services over 100G coherent tunable optical line • Provides ultra-long haul capability, up to 6000 km • Uses 60% less power than previous version • Pluggable QSFP28 client optics with performance monitoring • Support for up to 88 100G channels • Small form factor, with 100G in 1RU • Alien wavelength capacity upgrade to existing long haul, ultra-long haul and submarine line system • Power consumption : 80W (incl. optics) • Operating Temperature 0°C to +50°C MS430898M • Line Side • Integrated 100G coherent using DP-QPSK modulation • 127.156G nominal line rate • Proprietary framing • OTU4 into proprietary frame • 12.5 dB OSNR—6000 Km • CD Tolerance: ±50,000 ps/nm • PMD: 30 ps • Transmit Power -2 dBm • Receive Power -5 to -15 dBm • Tunable C-band • Client Side • 1 x QSFP28 pluggable • 100GbE client
Rack Mount 100G Muxponder (MXP100) • 100G Ultra-Long Haul Muxponder • Transports 10x10G multiprotocol services over 100G coherent tunable optical line • Provides ultra-long haul capability, up to 6000 km • Uses 45% less power than previous version • Pluggable SFP+ client optics with performance monitoring • Support for up to 88 100G channels • Small form factor, with 100G in 1RU • High density 8G/10G service aggregation • Fiber relief for congested routes • Alien wavelength capacity upgrade to existing long haul, ultra-long haul and submarine line system • Power consumption : 110W (incl. optics) • Operating Temperature 0°C to +50°C MS430899M • Line Side • Integrated 100G coherent using DP-QPSK modulation • 127.156G nominal line rate • Proprietary framing • OTU4 into proprietary frame • 12.5 dB OSNR—6000 Km • CD Tolerance: ±50,000 ps/nm • PMD: 30 ps • Transmit Power -2 dBm • Receive Power -5 to -15 dBm • Tunable C-band • Client Side • 10 x SFP+ pluggable • 8G FC, 10GbE, OC-192; STM-64; OTU2; OTU2e clients
Long Haul 10G Transponder • Metro, Regional and Long Haul transport, backhaul and business services applications • ETR variant for use in outdoor enclosures • Single slot 10G Transponder • ETR variant is dual slot • Link distances up to 300 km without in-line amplifiers and with full channel counts • Distances of more than 2000 km for multi-span • Power consumption : 27W (incl. optics) • Operating Temperature 0°C to +50°C • ETR variant: -40°C to +65°C MS430567MTX • Line Side • Single XFP line port • 12 dB OSNR • 10 dB FEC • 40 Km /80 Km 1550 nm DWDM • 80 Km Tunable @ 100GHz • FFI (ETR variant only) • 10 dB FEC • 80 Km Tunable @ 50GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 1 x SFP+ pluggable • 10GbE LAN/WAN, OC-192/STM-64 clients • RMON on 10GbE input • Loopback
10G Protocol Converter • Two slot 10G module • Converts 10G LAN PHY to 10G WAN PHY for transport over existing SONET/SDH networks • Rate adaptation done by removing IDLE frames • Eliminates the need for expensive router interfaces • 10G LAN monitoring on ingress and egress • Bits, bytes, frames, dropped frames, pause frames • Flow control mechanism can generate MAC pause frames to source device or drop frames if LAN rate exceeds WAN rate • 24 km max distance from source device • Power consumption : 24W (incl. optics) • Operating Temperature 0°C to +50°C MS430572M • Line Side • Single XFP line port • 12 dB OSNR • 40Km/80 Km 1550 nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 1 x XFP pluggable • 10GbE LAN client • RMON on 10GbE input • Client / XFI loopback
Dual 10G Transponder • Two-slot 2 x 10G Transponder, 1 x 10G Transponder with protection or 10G Regen • Metro, Regional and Long Haul transport, backhaul and business services applications • Performs full 3R (Retime, Reshape and Retransmit) signal regeneration • Link distances up to 300 km without in-line amplifiers and with full channel counts • Distances of more than 2000 km for multi-span • Power consumption : 66W (incl. optics) • Operating Temperature 0°C to +50°C MS430569M • Line Side • Dual XFP line ports • 12 dB OSNR • 10 dB FEC • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 2 x SFP+ pluggable • 10GbE LAN, OC-192/STM-64 clients • RMON on 10GbE input • Loopback
Video Muxponder • Three-slot module aggregates up to 4 video streams on a single 10G wavelength • Any combination of SDI, HD-SDI-PAL, HD-SDI-NTSC signals • Each port auto-senses signal type upon commissioning • Combine video with 1xFE + 1xGbE • Supports 6 video ports if FE & GbE not used • Variants with encryption and drop-and-continue (for broadcast) • Power consumption : 35W (incl. optics) • Operating Temperature 0°C to +50°C MS430654MV • Line Side • Dual XFP-based line ports • 21 dB OSNR • 40/80 Km 1550 nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G line rate • Loopback • Client Side • Coaxial BNC interfaces for SDI ports • Standard RJ45 port for FE • SFP for GbE • Loopback
Multiprotocol Muxponder • Two-slot module aggregates up to eight (8) client services on a single 10G wavelength • Any combination of 1G FC, 2G FC, 4GFC, OC-48/STM-16, OC-12/STM-4 and GbE signals • Any service, any port • Ideal for Business Services, DCI/Disaster Recovery, Triple or Quadruple Play, Wireless Backhaul, IP DLC/DSLAM Backhaul • LH module w/ DynaFEC (10dB gain) & 12 dBOSNR • Optional 1+1 ine protection w/ 50ms switching • Power consumption : • XFP: 38W (incl. optics) • Operating Temperature 0°C to +50°C MS430687M • Line Side • Single or dual XFP line ports • 12 dB OSNR • 10 dB FEC • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 8 x SFP for GbE • Client/XFI loopback
Multiprotocol Muxponder with ADM • Two-slot module aggregates up to eight (8) client services on a single 10G wavelength • Any combination of 1G FC, 2G FC, 4GFC, OC-48/STM-16, OC-12/STM-4 and GbE signals • Any service, any port • Ideal for Business Services, DCI/Disaster Recovery, Triple or Quadruple Play, Wireless Backhaul, IP DLC/DSLAM Backhaul • Metro module w/ 6.5 dB FEC gain & Add/Drop Multiplexing (ADM) capability • Optional 1+1 line protection w/ 50ms switching • Power consumption : • XFP line: 38W (incl. optics) • Operating Temperature 0°C to +50°C MS430686MDC • Line Side • Single or dual XFP line ports • 17 dB OSNR • 6.5 dB FEC • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 8 x SFP • Ring SNCP type protection on individual client protocol • Client/XFI loopback
10G Transponder • Single slot 10G regenerator module • Long Haul transport and backhaul applications • Performs full 3R (Retime, Reshape and Retransmit) signal regeneration • Link distances up to 300 km without in-line amplifiers and with full channel counts • Distances of more than 2000 km for multi-span • Power consumption : 10W (incl. optics) • Operating Temperature 0°C to +50°C MS430550M • Line Side • Single XFP line port • 21 dB OSNR • 40 Km /80 Km 1550nm DWDM • 80 Km Tunable @ 100GHz • Proprietary line format • 11.09G nominal line rate • Loopback • Client Side • 1 x XFP 40, 80 kmsB&W or DWDM • Any 10G from 9.95 Gbps to 11.09 Gbps • 10GbE LAN/WAN, OC-192/STM-64, OTU2, 10GFC • Client/XFIIoopback
10G OTN Transponder • Dual slot 6 x 10G OTN transponder • Full G.709 standards compliance • Provides low cost connection to/from switched OTN core network • 10-20µs latency • Power consumption : 30W (incl. optics) • Operating Temperature 0°C to +50°C MS430553M • Client Side • 6 x SFP+ • 10GbE; OC-192/STM-64 client interfaces • Terminal & Facility Ioopbacks • Line Side • 6 x SFP+ • G.709 OTU2/OTU2e line rate—11.096 Gbps • 17 dB OSNR • Terminal & Facility Ioopbacks
Quadrupler 16G Transponder • Four independent transponders on one single-slot blade • Supports 8G/10G/16G Fibre Channel and 10 Gigabit Ethernet • Up to 80 x 16G channels in a single chassis • Full 3R regeneration • Low latency • Power consumption : 15W (incl. optics) • Operating Temperature 0°C to +50°C MS430558M • Target Applications • Enterprise connectivity • Server and storage replication/virtualization • Business continuance and disaster recovery • (BC/DR) • Campus networking • Managed business services • Line Side • 4 x SFP+ • 8G/10G • 23 dB OSNR • 80Km Tubnable @ 100GHz • 16G • 25 dB OSNR • 40 Km 1550nm DWDM • Client Side • 4 x SFP+ • 8G/10G/16G FC & 10GbE • Client/XFIIoopback
CPRI Muxponder • Two slot module • Dual 4X 2.5G CPRI + 1 GbE over dual 10 G uplinks • Aggregate up to 9x CPRI or 8x CPRI and 2x Sync-E • Extended Temperature Range (ETR) compatible • Can be deployed in outdoor cabinet at cell site • Low latency—2 μs • Power consumption : 30W (incl. optics) • Operating Temperature 0°C to +50°C • ETR variant: -40°C to +65°C MS430671M • Target Applications • Mobile Front Haul • Client Side • 10 x SFP+ • 8 x CPRI Option 3 (2.5G) • 2 x Synchronous Ethernet (GbE) • RMON on GbE input • Line Side • 2 x SFP+ • Proprietary line format • 11.06G
STM1 Muxponder • Single slot module • 4 x OC-3/STM-1 client port interfaces or 1 x OC-12/STM-4 client port interface • Fully transparent transport of OC-3/STM-1 or OC-12/STM-4 client signals • 1.25Gbps line interface compatible with otherMuxponders client interface for further aggregation over higher speed links • Power consumption : 12W / 14W (incl. optics) • Operating Temperature 0°C to +50°C MS430614M • Target Applications • Business Services • Low speed aggregation • DSLAM backhaul • Client Side • 4 x SFP • 4 x OC-3 / STM-1 • 1 x OC-12 / STM-4 • Line Side • 1 x SFP, CWDM / DWDM • 1.25G
Two port GBE Muxponder • Single slot module • Dual mode • Aggregation of two GbE/GFC over OC-48/STM-16 • OC-48/STM-16 transport with 1+1 protection • Fully compatible with SONET/SDH equipment • Power consumption : 16W (incl. optics) • Operating Temperature 0°C to +50°C MS430605M • Target Applications • Ethernet services over SONET/SDH network • Protected OC-48 or STM-16 services • DSLAM backhauling • Line Side • 2 x SFP, CWDM / DWDM • OC-48 / STM-16 • Optional 1+1 line protection with APS feature • Client Side • 2 x SFP • 2 x GbE or 1G FC • 2 x OC-48 / STM-16 • RMON on GbE input
Quadruple Transponder • Single slot quad transponder • CWDM and DWDM transponder or repeater • Supports any protocol from 100M to 4G • Software selectable data rates • Full 3R signal regeneration • Power consumption : 13W (incl. optics) • Operating Temperature 0°C to +50°C MS430584M • Target Applications • CWDM & DWDM networks • Edge, Metro and Regional optical networks • SONET/ SDH, Ethernet and Storage networks • Regeneration sites • Wavelength conversion • Client Side • 4 x SFP • FastE, GbE, OC-3/12/48, STM-1/4/16, 1/2/4G Fibre Channel • RMON on GbE input • Line Side • 4 x SFP • CWDM / DWDM
LC Booster/Preamplifier • EDFA-based Optical Booster and Preamplifier (OABP) • Cost-efficient amplification solution for metro and regional applications • Operates in constant output power mode • Can be tuned to reach a required output power MS430866M • Size: Two slots • Power consumption: 4W • Connector: dual LC
LC In-Line Amplifier • EDFA-based In-Line amplifier (OAIL) • Cost-efficient amplification solution for metro and regional applications • Operates in constant output power mode • Can be tuned to reach a required output power MS430865M • Size: two slots • Power consumption: 4W • Connector: dual LC
HC Booster/Preamplifier • EDFA-based Optical Booster and Preamplifier (OABP) • High capacity amplification solution for metro and regional applications • Configurable for constant output power or constant gain modes • Output power is upgradable in-service in the field using pump module (see following slide) • Optical Supervisory Channel insertion and extraction for remote management (requires separate OSC card. See following slide) • Automatic Power Reduction (APR) mechanism • Shuts down output EDFA gain block when a loss of signal is detected on the input of an EDFA gain block to prevent any light emission in the broken fiber MS430845M • Size: Two slots • Power consumption: 12W • Connector: dual LC
HC In-Line Amplifier • High capacity amplification solution for metro and regional applications • Configurable to operate in constant output power or constant gain modes • Output power is upgradable in-service in the field using pump module (see following slide) • Bi-directional operation • Dual Optical Supervisory Channel insertion and extraction for remote management (requires separate OSC card) • Mid-stage access for Chromatic Dispersion devices • Automatic Power Reduction (APR) mechanism • Shuts down output EDFA gain block when a loss of signal is detected on the input of an EDFA gain block to prevent any light emission in the broken fiber • Extended Temperature Range (ETR) version is designed for operating in outside cabinets or unconditioned spaces • Ambient temperature range of -40°C to +65°C MS430846MX • Size: two slots • Power consumption: 12W • Connector: dual LC
HCS-17 Variable Gain Amplifiers • EDFA-based Optical Booster / Preamplifier (OABP), or bi-directional Optical In-line Amplifier (OAIL) variants • Integrated 1510 nm Optical Supervisory Channel (OSC) insertion and extraction—no external OSC required • Automatic fiber aging compensation • Automatic adjustment of optical power as channels are added and removed • Configurable for constant output power or constant gain modes • Mid-stage access for Chromatic Dispersion devices (OAIL) MS430849M-17 MS430848M-17 • Size: two slots • Power consumption • OABP: 5W • OAIL: 6W • Connector: dual LC
HCS-20 Variable Gain Amplifiers • EDFA-based Optical Booster / Preamplifier (OABP), or bi-directional Optical In-line Amplifier (OAIL) variants • Integrated 1510 nm Optical Supervisory Channel (OSC) insertion and extraction—no external OSC required • Automatic fiber aging compensation • Automatic adjustment of optical power as channels are added and removed • Configurable for constant output power or constant gain modes • Mid-stage access for Chromatic Dispersion devices (OAIL) MS430849M-20 MS430848M-20 • Size: two slots • Power consumption • OABP: 5W • OAIL: 6W • Connector: dual LC
Optical Pump • External optical pump providing 3 dBm optical output power for EDFA HC • Increases optical output power (Pout) to each amplifier (Booster, Pre-Amp and In-Line) to +20dBm (with one external pump) or +23dBm (with two external pumps) • Uses two individual laser pumps—one for each direction of the amplifier MS430847M • Size: one slot
Optical Supervisory Channel • The OSC provides a dedicated communications channel used for the remote management • Three port Ethernet switch: • One electrical port on the backplane connector to connect to MNGT card • Two optical port through SFP on the front panel • Alarms provided: • OSC 1 and OSC 2 Loss of incoming Signal • OSC 1 and OSC 2 Laser Shutdown • Measures provided: • SFP temperature in °C • SFP voltage in V • SFP receive power in dBm • SFP transmit power in dBm • SFP laser pump current (bias) in mA • DDM (Digital Diagnostic Monitoring) information from SFP MS430890M • Size: one slot • Power consumption: 7W • Connector: SFP
Raman Amplifier • Designed for long single-span links and elimination of intermediate amplifier sites (hut skipping) • Works with 10G, 100G and 200G line rates • Provides OSNR improvement compared to EDFA only • Contra-directional and co-directional operation • Can be used on its own or with EDFAs • Comprehensive eye safety - Class 1M • Automatic shutdown and restart • Alerts for fiber link degradation and/or gain reduction MS430852M • Size: one slot • Power consumption: 35W • Connector: • E2000 HP (amplified output signal) • LC (input signal)
ROPA System • Allows for ultra-long spans up to 450km* with no in-line active components • All active components in the system are located at the terminal site of a WDM span, even when inline amplification is necessary • Supports both single-channel and WDM links over typical usable spectrum of 1547nm to 1560nm • Consists of two components • MS430835M(Remote Amplifier Pump): Remotely pumps the ROA in the fiber amplifying the WDM channels that pass through it • MS430837M(Remote Optical Amplifier): Spliced into the fiber within 80km of the location of the RAP. Can be mounted vertically or horizontally • MS430835M has three pump laser diodes at wavelengths 1424 nm and 1452 nm and features multiple independent laser safety features based on Automatic Power Reduction (APR) • MS430837M is purely passive and can be housed in an independent splice box or can be installed in an existing splice box on the route MS430835M • Size: 1RU • Line Connector: • CE2000 High Power Connector MS430837M *Based on 10G wavelengths