1 / 14

PFR design. Accounting for pressure drop

PFR design. Accounting for pressure drop. Chemical Reaction Engineering I Aug 2011 - Dec 2011 Dept. Chem. Engg., IIT-Madras. Overview. Notation PFR design equation (mass balance) Pressure drop equation Accounts for change in number of moles (due to reaction)

thimba
Download Presentation

PFR design. Accounting for pressure drop

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PFR design. Accounting for pressure drop Chemical Reaction Engineering I Aug 2011 - Dec 2011 Dept. Chem. Engg., IIT-Madras

  2. Overview • Notation • PFR design equation (mass balance) • Pressure drop equation • Accounts for change in number of moles (due to reaction) • Does not consider phase change • Methodology, with examples • Liquid phase reaction: Calculations are simple • Gas phase reaction: Calculations are more involved

  3. Notation • Usual notation applies. • FA = molar flow rate of A, FT = total molar flow rate • V = volume of reactor, Q = volumetric flow rate • D = diameter and A = cross-sectional area of PFR, L = length of PFR, z = distance (between 0 and L) • T = temperature, R = universal gas constant, P = pressure, PA = partial pressure of A • x = conversion, e = fractional increase in number of moles for 100% conversion, for a given feed conditions. • k = rate constant, CA = concentration of A • r = density, m = viscosity • ff = friction factor, Re = Reynolds number • <Vav> = average velocity of the fluid in the PFR. Used sparingly. • Subscript “in” indicates inlet. E.g. FA-in is molar flow rate of A at the inlet.

  4. Definitions and formulas The following definitions are of use here: Definition of ‘x’ Definition of ‘e’ Definition of CA For gas phase only: From ideal gas law At constant temperature

  5. Formulas For liquid as well as gas phase You don’t need to memorize these formulas

  6. PFR design equation • Steady state conditions • For a first order reaction • At constant temperature

  7. PFR design equation • For any other order of reaction also, write the equation such that dx/dz = f(x,P). i.e. The only unknowns on the RHS must be x and P • i.e. RHS must not have Q or CA. These are not known yet. • But Qin and CA-in are known and hence RHS may have these terms. • For an ‘n’th order reaction

  8. Pressure Drop Equation • Under steady state conditions, Reynolds number is a constant • Even though local velocity changes • This is because density also changes with location • We assume that the viscosity of the medium remains the same, even when the reaction occurs • Under steady state conditions, (rQ) = constant • Using Re, Calculate the friction factor ff. • Write pressure drop equation

  9. Solution • Solve both equations simultaneously • Initial conditions: • At z =0, P = Pin • At z = 0, x = 0 • Special case: • When e =0, solve the first equation and find ‘P’. Then substitute for ‘P’ in the second equation and solve for ‘x’

  10. Example • Consider a gas phase reaction under isothermal conditions. (Isomerization) • A B • Pin = 10 atm, Q = 0.005 m3/s, T = 300 K, Pure A is fed, k = 0.1 lit/s, Molecular weight M = 60 g/gmol, Viscosity of the gas = 10-5 Pa-s • What should be the length of the PFR if it is constructed (a) using a 2 cm pipe and the conversion desired is 10%? (b) using a 1.5 cm pipe and the conversion desired is 10% and (c) using a 1.5 cm pipe and the conversion desired is 20%

  11. Solution • e= 0. This simplifies the equations R=0.08206 atm-lit/(gmol-K)

  12. Dia = 2 cm

  13. Dia = 2 cm, expanded

  14. Dia = 1.5 cm • 10% conversion is possible, but 20% is not

More Related