1 / 45

DETECTIA PERIMETRALA SISTEME DE DETECTIE DE EXTERIOR

DETECTIA PERIMETRALA SISTEME DE DETECTIE DE EXTERIOR. Scopul detectiei de exterior. Detectie Intirziere Evaluare alarma Raspuns Cunoasterea amenintarii este esentiala pentrru proiectarea unui sistem eficient. Considerente de proiectare. Care este amenintarea/tinta? Perceputa

thuyet
Download Presentation

DETECTIA PERIMETRALA SISTEME DE DETECTIE DE EXTERIOR

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DETECTIA PERIMETRALASISTEME DE DETECTIE DE EXTERIOR

  2. Scopul detectiei de exterior • Detectie • Intirziere • Evaluare alarma • Raspuns Cunoasterea amenintarii este esentiala pentrru proiectarea unui sistem eficient.

  3. Considerente de proiectare • Care este amenintarea/tinta? • Perceputa • Reala – Cit de inteligent este intrusul? (Terorist, hot, vandal?) • Este necesara securitatea exterioara? • Care este costul unui eveniment? (Intirzieri, pierderi de informatii, costuri de reparatie, publicitate negativa?)

  4. Caracteristici de performanta • Pd – Probabilitatea de detectie • Combinatia sensibilitatii senzorilor, mediul, conformitatea cu specificatiile de instalare • RAF – Rata alarmelor false • Rata alarmelor datorate functionarii defectoase a echipamentului (ex. contact de sabotaj defect). • RAZ – Rata alarmelor de zgomot • Rata alarmelor datorate unei perturbatii din mediu pentru care senzorul a fost proiectat neasociate unor intruziuni. • Vs – Vulnerabilitatea la sabotare

  5. Detectia antiefractie inseamna mai mult decit senzorii • Detectia fara evaluare si raspuns este inutila • Timpul de raspuns este esential • Raspuns lent – infractorul dispare • Precizia in interventie (locul) • Evaluarea si raspunsul tin de factorul uman • Cit de prietenos in exploatare este sistemul? • Cit de pregatit este operatorul?

  6. Tipuri de senzori • Pentru garduri • Cabluri, mecanici, sirma tensionata (taut wire), fibra optica • In linia de vizibilitate • Microunde, infrarosu • Ingropati • Cablu coaxial, fibra optica, senzori seismici • Detectie video a miscarii • CCTV

  7. X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Sectiune tipica intr-un sistem LUMINA CCTV 100 M MONTANT ILUMINATOR ELEMENT DE EVALUARE CCTV SENZOR DE GARD MICROUNDA GARD DE SECURITATE SENZOR INGROPAT

  8. Gard • Mecanic • Cablu senzitiv • Fibra optica • Taut wire • Cimp electric • Localizare in puls

  9. Gard – Perturbatii mecanice • Senzori discreti - geofon • Vibratie / miscare • Permit setarea lungimii zonei

  10. x x x x x x x x x x x x x x x x x x x x x x x Diagrama - perturbatii mecanice x x x x x x x x x x x x x x x x x x x x x SENZOR CABLU PROCESOR CONDCTOR

  11. Gard – Cablu senzitiv • Sensibilitate uniforma • Necesita gard in stare buna • Permite setarea lungimii zonei

  12. Amplasare cablu senzitiv

  13. Gard – Fibra optica • Detecteaza miscarea, schimbari de prsiune • Acoperire maxim 2000m. • Detecteaza schimbarea modului de propagare a luminii. • Necesita procesare la ambele capete.

  14. Amplasare fibra optica

  15. Gard – Taut Wire • Tipuri de senzori • Contacte mecanice • Piezoelectric • Strain gage • INstalare – Independenta sau atasat de gard. • Zone definite de amplasarea senzorilor

  16. Gard – Amplasare taut wire STILP DE ANCORARE CABLURI TENSIONATE AMPLASARE SENZORI

  17. Gard – Cimp electric • Cimp electrostatic in jurul firelor • Detecteaza un intrus in cimpul creat • Amplasare independenta sau atasat de gard

  18. S S f = Cabluri generatoare S = Cablul senzitiv f f f Gard Gard S S Senzor cu 3 fire Senzor cu 4 fire Amplasare cimpe electric

  19. Gard – Localizare in puls • Cablu cu localizare cu puls RF – precizie 3m • Zonele pot fi setate oriunde pe cablu • Permite detectia, comunicatia si alimentarea pe acelasi cablu. • Filtreaza vintul si ploaia cu localizare.

  20. Amplasare

  21. Senzori in linia de vizibilitate • Microunde • Bistatic – Unitati separate de emisie si receptie • Monostatic – Unitate TX & RX • Infrarosu - Active & Pasive • Bariere cu TX & RX • Unitati singulare

  22. Bariere microunde • Emitator si receptor separati • Disponibili in benziel K si x • X Band 10.5Ghz • K Band 24 Ghz • Detectie volumetrica • Necesita teren plat

  23. Diagrama bariera microunde RECEPTOR EMITATOR FLUX MICROUNDE CUTIE JONCTIUNI CAI DE PROPAGARE MULTIPLA CABLU

  24. Bariere supraetajate Inaltime de detectie crescuta

  25. Senzor cu microunde monostatic • O singura unitate TX & RX • Disponibile in benzile K si X • Detectie pe baza efectului Doppler • Necesita setarea distantei de detectie • Amplasare fixa / portabila

  26. CIMP MICROUNDE SENZOR GARD DELIMITARE Diagrama de amplasare

  27. SENZORI ACTIVI IR • Emitator si receptor separati • Detectie in proximitatea liniei virtuale dintre emitator si receptor • Aliniere critica

  28. Diagrama bariere IR Spoturi IR T R R T T R R R T R R R T R R R T T R R T = TRANSMITTERR = RECEIVER

  29. Senzori pasivi IR • O unitate TX/RX • Detecteaza amprenta terminca • Lob ingust • Acoperire max. 120m

  30. Senzori ingropati • Cablu coaxial – cimp RF • Fibra optica • Senzori seismici

  31. Cablu coaxial ingropat • Cimp RF • Detecteaza miscarea in cimp • Configuratii cu 1 sau 2 cabluri • Urmareste foram terenului • Atentie la sol cu compusi metalici

  32. Diagrama cablu coaxial Adincime de ingropare critica 1,5 – 4 m 1 m Detection Zone Cabluri RF 1 – 3m DUAL CABLE TYPE

  33. FIBRA OPTICA INGROPATA • Detecteaza vibratiile produse de pasi • Amplasare in forma de S pentru cresterea sensibilitatii • Necesita procesare la ambele capete • De evitat zone cu eroziune, radacini de copaci, asfalt…

  34. Senzori seismici ingropati • Senzori independenti pt. vibratii de joasa frecventa • Le ingroapa la distanta de 3-4m • De evitat zone cu trafic intens: cai ferate, autostrazi

  35. Detectia video de miscare • aceeasi tehnologie ca la interior • Necesita montare rigida a camerelor • De evitat schimbari bruste de lumina sau vreme

  36. Considerente ref. la obiectiv • Factori climatici • Eliminarea si controlul vegetatiei • Particularitati teren • Planeitatea solului • Obstructii, canale • Animale

  37. Probability of Detection Chart TUNNEL CUT/LIFT WALK RUN CRAWL CLIMB SENSOR FENCE MOUNTED N - H - - M-H TAUT WIRE - - - H H N ELEC FIELD VH VH H VH VH N CAPACITANCE - N - - VL VH PORTED COAX - - H VH VH M - MICROWAVE H - H M-H N - - VH INFRARED N VH M-H - - VH M N VIDEO MOTION H

  38. SENSOR FENCE MOUNTED TAUT WIRE ELEC FIELD CAPACITANCE PORTED COAX MICROWAVE INFRARED VIDEO MOTION Nuisance & Environmental Alarms RAIN/ POWER WIND SNOW WATER FOG ANIMALS BIRDS LIGHTNING LINES N L-M L-M L VL H L-M N VL N VL-L VL VL VL VL N M VL M-VH M H VL L H M N L-M M M M L VL VL L VH VL M H VL L L VH M L-M L L L M-H L L VH L-M L VL M-H L-M M L VH L-M L-M L M-H L-M

  39. TYPE OF SENSOR EQUIPMENT INSTALLATION MAINTENANCE FENCE MOUNTEDTAUT WIREELECTRIC FIELDCAPACITANCEPORTED CABLEMICROWAVEINFRAREDVIDEO MOTION LHHMHMMM LHMLMMLL LHHMLMMM-H Relative Costs of IDS

  40. Obstacole in perimetru • Porti • Microunda, IR, gard • Cladiri in perimetru • Microunde, IR, taut wire. • Canale colectoare • Briere fizice

  41. X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Cablu senzitiv Exemplu porti intrare Poarta translatie Gard interior T R R T Gard exterior Poarta translatie BAriere cu microunde pentru zona de acces Porti batante Amplasare cablu senzitiv pe porti batante

  42. Exemplu Cladiri in perimetru X X X X X X X X X X IR R GARD CLADIRE T T X X X X X X X X X X SENZOR CU REFLECTOR TAUT WIRE TAUT WIRE, RAZOR WIRE w/ Sensor

  43. CANALE COLECTOARE • Bariere fizice (mecanice) • Se instaleaza o mica teava in interior • Senzori de protectie perimetrala

  44. Cerinte protectie perimetrala • Scop • Detectie, intirziere, evaluare, raspuns • Perimetru: o linie continua si neintrerupta de senzori • Risc / amenintare • Scazuta = o linie de senzori • Mediu/ridicat = mai multe tipuri de senzori pe nivele diferite

  45. Sumar detectie exterior • Ofera detectie timpurie • Mult mai scumpa ca detectia de interior • Trebuie sa opereze in conditii dificile de mediu • Succesul depinde de prioectare, instalare si training

More Related