1 / 51

MICRO FLOWS: AN INTRODUCTION Michael Shusser

MICRO FLOWS: AN INTRODUCTION Michael Shusser. SIZE RANGES OF MACRO, MICRO, AND NANO DEVICES. FLUID FLOW AND HEAT TRANSFER IN SINGLE-PHASE FLOW OF A NEWTONIAN FLUID IN A MICRO-CHANNEL. NO MULTIPHASE FLOW NO POLYMERS OR BIO-FLUIDS NO COMPLEX GEOMETRIES NO ELECTRO-KINETIC FLOWS.

uriel-oneil
Download Presentation

MICRO FLOWS: AN INTRODUCTION Michael Shusser

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MICRO FLOWS: AN INTRODUCTIONMichael Shusser

  2. SIZE RANGES OF MACRO, MICRO, AND NANO DEVICES

  3. FLUID FLOW AND HEAT TRANSFER IN SINGLE-PHASE FLOW OF A NEWTONIAN FLUID IN A MICRO-CHANNEL • NO MULTIPHASE FLOW • NO POLYMERS OR BIO-FLUIDS • NO COMPLEX GEOMETRIES • NO ELECTRO-KINETIC FLOWS

  4. IS EVERYTHING DIFFERENT OR JUST SMALLER?

  5. IS THE CONTINUUM APPROXIMATION VALID? POSSIBLE NON-CONTINUUM EFFECTS: • SLIP AT THE BOUNDARY • STRESS/RATE OF STRAIN RELATION IS NONLINEAR • CONTINUUM APPROXIMATION FAILS

  6. FOR THE TIME BEING WE ASSUME THAT THE CONTINUUM THEORY IS VALID • LIQUIDS • GASES FOR L > 5 μM

  7. MANY OF STUDIES OF BASIC HEAT AND FLUID FLOW PROBLEMS IN BASIC GEOMETRIES FOUND LARGE DEVIATIONS FROM EXPECTED RESULTS • FRICTION FACTOR f • NUSSELT NUMBER Nu • CRITICAL REYNOLDS NUMBER ReC

  8. LAMINAR FLOW OF AN INCOMPRESSIBLE FLUID WITH CONSTANT PROPERTIES IN A CIRCULAR PIPE • FRICTION FACTOR • REYNOLDS NUMBER • POISEUILLE NUMBER

  9. SCALING EFFECTS • THE EFFECTS THAT CAN BE NEGLECTED IN MACRO SCALES BUT ARE IMPORTANT IN MICRO SCALES ARE CALLED SCALING EFFECTS • PROVIDED THE CONTINUUM APPROXIMATION REMAINS VALID, ALL THE DISCREPANCIES BETWEEN MICRO AND MACRO FLOWS CAN BE EXPLAINED AS SCALING EFFECTS

  10. ENTRANCE EFFECTS • VISCOUS HEATING • TEMPERATURE- AND PRESSURE DEPENDENT PROPERTIES • WALL ROUGHNESS • COMPRESSIBILITY • CONJUGATE HEAT TRANSFER • AXIAL HEAT CONDUCTION

  11. ENTRANCE EFFECTS FOR LAMINAR FLOW IN A CIRCULAR PIPE

  12. WATER FLOW IN A 2D CHANNEL – CFD/EXPERIMENT

  13. ENTRANCE EFFECTS ARE NOT ALWAYS NEGLIGIBLE IN MICRO FLOWS • DEVELOPING FLOW IS STRONGLY INFLUENCED BY THE INLET VELOCITY PROFILE • THERE IS NOT ENOUGH DATA ON ENTRANCE EFFECTS FOR VARIOUS CROSS-SECTIONS

  14. VISCOUS HEATING ENERGY EQUATION FOR FLOW IN A PIPE VISCOUS HEATING (VISCOUS DISSIPATION)

  15. BRINKMAN NUMBER • THE IMPORTANCE OF THE VISCOUS HEATING TERM IS DETERMINED BY THE BRINKMAN NUMBER • FOR EXAMPLE, FOR CONSTANT HEAT FLUX • IN MACRO FLOWS VISCOUS HEATING IS IMPORTANT ONLY FOR VERY VISCOUS FLUIDS OR VERY HIGH VELOCITIES

  16. IN MICRO FLOWS BRINKMAN NUMBER IS USUALLY VERY SMALL • WATER:μ = 8.55·10-4 kg(m·s) k = 0.613 W/(m·K) ΔT = 1 ºC um = 0.1 m/s Br ≈ 1.4·10-5 • AIR: μ = 1.846·10-5 kg(m·s) k = 0.0263 W/(m·K) ΔT = 1 ºC um = 1 m/s Br ≈ 7·10-4 • THE INFLUENCE OF VISCOUS HEATING ON HEAT TRANSFER IN MICRO FLOWS IS USUALLY NEGLIGIBLE

  17. VISCOUS HEATING CAN BE IMPORTANT DUE TO VERY STRONG DEPENDENCE OF LIQUID VISCOSITY ON TEMPERATURE WATER T = 300 K ν = 8.576·10-7 m2/s T = 310 K ν = 6.999·10-7 m2/s TEMPERATURE RISE OF 10 K CAUSES 18% DECREASE IN KINEMATIC VISCOSITY WHICH RESULTS IN CORRESPONDING INCREASE OF THE LOCAL Re NUMBER AFFECTING THE FRICTION FACTOR

  18. THERMAL EXPLOSION THE MOMENTUM AND ENERGY EQUATIONS FOR FULLY DEVELOPED FLOW IN A CIRCULAR PIPE ARE FOR EXPONENTIAL DEPENDENCE OF LIQUID VISCOSITY ON THE TEMPERATURE

  19. INTRODUCING NEW VARIABLES THE ENERGY EQUATION REDUCES TO IT HAS NO SOLUTION FOR NO FULLY DEVELOPED FLOW!

  20. ISOPROPANOL FLOW IN A SQUARE MICRO CHANNEL • L = 11.4 cm; D = 74.1 μm; (L/D = 1543) • FOR Re ≈ 300 Tin - Tout =6.2 oC

  21. EXAMPLE OF A CFD RESULT • INLET CONDITIONS D= 20 μm; T = 300 K ν = 8.576·10-7 m2/s Re = 2000 V = 85.76 m/s !

  22. VISCOUS HEATING HAS USUALLY NO INFLUENCE ON HEAT TRANSFER IN MICRO FLOWS • ITS INFLUENCE ON FRICTION FACTOR CAN BE IMPORTANT DUE TO VERY STRONG DEPENDENCE OF LIQUID VISCOSITY ON TEMPERATURE, ESPECIALLY FOR LONG CHANNELS

  23. VARIABLE PROPERTIES • DUE TO LARGE GRADIENTS IN MICRO FLOWS THE DEPENDENCE OF PROPERTIES ON PRESSURE AND TEMPERATURE IS IMPORTANT • LIQUIDS SHOULD BE MODELED AS INCOMPRESSIBLE WITH TEMPERATURE-DEPENDENT VISCOSITY • SOMETIMES PRESSURE-DEPENDENCE OF VISCOSITY SHOULD ALSO BE TAKEN INTO ACCOUNT

  24. LIQUID FLOW AT 30 MPa

  25. COMPRESSIBILITY EFFECTS • THE FRICTION-INDUCED PRESSURE DROP PER TUBE LENGTH COULD BE LARGE IN FLOW THROUGH A NARROW CHANNEL • COMPRESSIBILITY EFFECTS CAN BE IMPORTANT IN GAS FLOWS EVEN FOR LOW MACH NUMBERS

  26. PRESSURE AND DENSITY VARIATIONS ALONG THE TUBE AT DIFFERENT INLET MACH NUMBERS

  27. WALL ROUGHNESS • ROUGHNESS LEADS TO INCREASING FRICTION FACTOR AT THE SAME Re NUMBER AND DECREASING VALUE OF THE CRITICAL Re NUMBER (EARLIER TRANSITION FROM LAMINAR TO TURBULENT FLOW) • THE INFLUENCE OF THE ROUGHNESS IS DETERMINED BY ITS GRAIN SIZE ks AND FRICTION VELOCITY v* (OR WALL SHEAR STRESS τw)

  28. FLOW REGIMES FOR ROUGH PIPES

  29. FOR LOW Re (D < 100 μm) SOME EXPERIMENTS OBSERVED DEVIATIONS FROM THE CLASSICAL THEORY INCLUDING THE INFLUENCE OF ROUGHNESS IN LAMINAR FLOW • ONE POSSIBLE REASON FOR THE DISCREPANCY IS NON-UNIFORMITY OF THE ROUGHNESS • THERE IS NOT ENOUGH DATA ON INFLUENCE OF ROUGHNESS ON HEAT TRANSFER

  30. CONJUGATE HEAT TRANSFER • IN MICRO FLOWS THE RELATIVE THICKNESS OF THE CHANNEL WALL s/Dh IS USUALLY MUCH LARGER THAN IN MACRO FLOWS • THEREFORE CONVECTIVE HEAT TRANSFER IN THE FLUID AND HEAT CONDUCTION IN THE WALL MUST BE ACCOUNTED FOR SIMULTANEOUSLY • THIS CONJUGATED HEAT TRANSFER IS USUALLY NEGLIGIBLE FOR MACRO FLOWS

  31. EXPERIMENT • LAMINAR FLOW Re ≈ 50 L/D ≈ 160 • CONSTANT WALL HEAT FLUX

  32. THEORETICAL SOLUTION • WALL TEMPERATURE • BULK TEMPERATURE • NUSSELT NUMBER

  33. EXPERIMENT - RESULTS

  34. CFD – CONJUGATE HEAT TRANSFER INCLUDED

  35. AXIAL CONDUCTION NUMBER • THE IMPORTANCE OF THE CONJUGATE HEAT TRANSFER IS GIVEN BY THE AXIAL CONDUCTION NUMBER M

  36. THE NUMBER M IS USUALLY VERY LOW FOR MACRO CHANNELS (HIGH V, SMALL eS/ef, LARGE L) BUT CAN BE LARGE FOR MICRO CHANNELS (LOW V, eS/ef IS NOT SMALL, SMALL L) • FOR LARGE M THE WALL HEAT FLUX BECOMES STRONGLY NON-UNIFORM: MOST OF THE HEAT IS TRANSFERRED TO THE FLUID NEAR THE ENTRANCE TO THE CHANNEL

  37. AXIAL HEAT CONDUCTION ENERGY EQUATION FOR FLOW IN A PIPE AXIAL HEAT CONDUCTION • AXIAL HEAT CONDUCTION CAN USUALLY BE NEGLECTED UNLESS PECLET NUMBER IS VERY LOW

  38. OILS: Pr >>1 LIQUIDS: Pr ~ 5 GASES: Pr ~ 0.7 LIQUID METALS: Pr << 1 • IN MACRO FLOWS THE AXIAL HEAT CONDUCTION IS NEGLIGIBLE EXCEPT LIQUID METAL FLOWS • IN MICRO FLOWS THE AXIAL HEAT CONDUCTION SOMETIMES MUST BE TAKEN INTO ACCOUNT

  39. TURBULENCE IN MICRO FLOWS • MICRO FLOWS ARE USUALLY LAMINAR (Re < 2000) • MOST EXAMPLES OF TURBULENT FLOW ARE USUALLY FOR RELATIVELY LARGE DIAMETERS (D > 300 μm) • FOR LARGE PRESSURE DIFFERENCE, GAS FLOWS CAN BE TURBULENT EVEN FOR SMALL DIAMETERS

  40. CFD: PIPE FLOW • D = 50 μm; PIN ≈ 20 atm; POUT ≈ 2 atm • VISCOUS COMPRESSIBLE TURBULENT FLOW • INLET: VX ≈ 125 m/s Re ≈ 25,000 • DO STANDARD TURBULENCE MODELS (LIKE k-ε) WORK IN THIS CASE?

  41. NON-CONTINUUM EFFECTS - GASES • THE FLOW IS RAREFIED FOR GASES AND THE WALLS “MOVE” • TO A CERTAIN DEGREE THE SITUATION IS SIMILAR TO LOW-PRESSURE HIGH-ALTITUDE AERONAUTICAL FLOWS • HOWEVER, REYNOLDS AND MACH NUMBERS ARE MUCH LOWER

  42. MOLECULAR MAGNITUDES • NUMBER DENSITY OF MOLECULES n • MEAN MOLECULAR SPACING δ • MOLECULAR DIAMETER d DILUTE GAS: δ/d > 7 AIR: THE DATA FOR p = 1 atm; T = 0 ºC

  43. MEAN FREE PATH • THE DISTANCE TRAVELED BY THE MOLECULES BETWEEN COLLISIONS IS KNOWN AS MEAN FREE PATH λ AT p = 1 atm; T = 25 ºC

  44. KNUDSEN NUMBER • THE KEY DIMENSIONLESS PARAMETER IS THE KNUDSEN NUMBER Kn

  45. LIMITS OF APPROXIMATIONS

  46. NON-CONTINUUM EFFECTS - LIQUIDS • FOR SUFFICIENTLY HIGH STRAIN RATE THE STRESS/RATE OF STRAIN AND HEAT FLUX/TEMPERATURE GRADIENTS RELATIONS BECOME NONLINEAR HERE τ IS THE MOLECULAR TIME-SCALE • THE CRITICAL VALUE IS VERY HIGH FOR ORDINARY LIQUIDS BUT NOT SO FOR COMPLEX FLUIDS

  47. FUTURE DIRECTIONS OF RESEARCH

  48. CONCLUSIONS • PROVIDED THE CONTINUUM APPROXIMATION REMAINS VALID, ALL THE DISCREPANCIES BETWEEN MICRO AND MACRO FLOWS CAN BE EXPLAINED AS SCALING EFFECTS • THE MAIN SCALING EFFECTS ARE VARIABLE PROPERTIES, COMPRESSIBILITY, CONJUGATE HEAT TRANSFER • SOME INFLUENCE OF ENTRY LENGTH, VISCOUS HEATING, AXIAL HEAT CONDUCTION AND ROUGHNESS IS ALSO POSSIBLE

  49. REFERENCES • Bayraktar & Pidugu, Int J Heat Mass Trans, 2006 • Cui et al, Phys Fluids, 2004 • Gad-el-Hak, Int J Heat Mass Trans, 2003 • Gamrat et al, Int J Heat Mass Trans, 2005 • Guo & Li, Int J Heat Mass Trans, 2003 • Herwig & Hausner, Int J Heat Mass Trans, 2003 • Herwig, ZAMM, 2002 • Hetsroni et al, Int J Heat Mass Trans, 2005, p. 1982 • Hetsroni et al, Int J Heat Mass Trans, 2005, p. 5580 • Judy et al, Int J Heat Mass Trans, 2002 • Karniadakis & Beskok, Micro Flows, 2002 • Koo & Kleinstreuer, Int J Heat Mass Trans, 2004 • Maranzana et al, Int J Heat Mass Trans, 2004

More Related