1 / 36

HYDROELECTRIC AND PUMPED STORAGE

HYDROELECTRIC AND PUMPED STORAGE. PRESENT WORLD CAPACITY = 630 GW POWER = DELTA P x FLOW RATE POWER (W) =. H =METRES, Q = CUSECS. WORLD TOTAL = 630GW. Kaplan turbine, propeller, large Q, low H Can change blade angle. Need to run at constant speed. More than 100m Pelton wheel or

urvi
Download Presentation

HYDROELECTRIC AND PUMPED STORAGE

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HYDROELECTRIC AND PUMPED STORAGE • PRESENT WORLD CAPACITY = 630 GW • POWER = DELTA P x FLOW RATE • POWER (W) = H =METRES, Q = CUSECS

  2. WORLD TOTAL = 630GW

  3. Kaplan turbine, propeller, large Q, low H Can change blade angle Need to run at constant speed More than 100m Pelton wheel or Impulse turbine Francis turbine vary output by Q Radial inflow

  4. TIDAL TURBINE

  5. FRANCIS TURBINE

  6. FRANCIS TURBINE

  7. POWER CONTROLLED BY FLOW RATE, Vcup = Vjet/2

  8. 18 SETS OF 700 MW =12.6 GW, H=120M, FLOW = 9000 TONNES/S

  9. CRUACHAN PUMPER STORAGE SCHEME

  10. CRUACHAN RESERVOIR AND LOCH AWE

  11. DINORWIG PUMPED STORAGE IN WALES

  12. TIDAL POWER GRAVITATIONAL AND CENTRIFUGAL FORCES CAUSED BY THE EARTH-MOON INTERACTION TOTAL UK POTENTIAL = 17% OF CURRENT ELECTRICTY GENERATION

  13. 12.5 HRS 50 MINS LATER EACH DAY 29.5 DAY CYCLE 14 DAYS BETWEEN SPRING & NEAP SUN PULL IS 177 BIGGER THAN MOON MID OCEAN TR=0.5M NEAR COASTS TR AMPLIFIED UP TO 15M

  14. MUTUAL ROTATION ABOUT COMMON CENTRE GIVES LARGE OUTWARD G FORCE ON SEA ON FAR SIDE & SMALL G FORCE ON NEAR SIDE. PULL OF MOON STRONG ON NEAR SIDE, WEAKER THAN AVERAGE ON FAR SIDE SUM APPROX SAME ON BOTH SIDES

  15. 2 miles of permanent mud at Weston – super - Mare

  16. AREA = A R MASS OF TRAPPED WATER = C OF G = R/2 ABOVE LOW WATER MARK MAX PE IF ALL WATER FALLS R/2 = Over tidal period ‘t’ average PE =

  17. Reversible pumps/turbines better than sluice gates

  18. Turbines 6000MW between high & low basins, 2500 MW high & sea Pumps 2500MW

  19. WAVE ENERGY UP TO 2MW/m Average 80kW/m Twice as much available in UK territorial waters As current installed generating capacity Seasonal peak in the winter Storms a problem

  20. ANNUAL AVERAGE WAVE POWER IN KW/M

  21. SALTER DUCK WAVE POWER CONVERTER

  22. SALTER DUCK WAVE ENERGY CONVERTER

More Related