Thermo-mechanical activities at Valencia

8 th International Workshop on DEPFET Detectors and applications. Thermo-mechanical activities at Valencia. V. Castillo, C. Lacasta, A. Oyanguren, P. Ruiz. (IFIC - Valencia). 21/9/2011. Outline.  M ock-up status at VLC.  Studies of air flow cooling:

vanig
Download Presentation

Thermo-mechanical activities at Valencia

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 8th International Workshop on DEPFET Detectors and applications Thermo-mechanical activities at Valencia V. Castillo, C. Lacasta, A. Oyanguren, P. Ruiz (IFIC - Valencia) 21/9/2011

  2. Outline  Mock-up status at VLC  Studies of air flow cooling: - Effect of CO2 cooling + air flow at several temperatures on the ladders  Conclusions  Plans at VLC Arantza Oyanguren 2 8th International Workshop on DEPFET Detectors and Applications

  3. Mock-up CO2 open system Nitrogen liquidDewar (cooled air) Thermally isolated box withdryatmosphere Mock-up IR camera chiller Arantza Oyanguren 3 8th International Workshop on DEPFET Detectors and Applications

  4. Mock-up • Mock-up status: • - Mechanical dummy temporarily fixed in the CrCo sample: • (plastic nut + screw ended with a wire embedded in the hole) • Thermal grease for the thermal contact • One resistor sample in the outer layer • - Set voltages: • Sensor: 12 V  P ~ 1W • Switchers: 3V  P ~ 0.25 W • DCDs/DHPs: 20V  P ~2.5 W It works! (appart from the left switchers) Arantza Oyanguren 4 8th International Workshop on DEPFET Detectors and Applications

  5. Mock-up Calibration tool for the IR camera: ( depends on the material) Al box filled with coolant: cooled down with chiller, heated with heaters. Study material   ~ 0.65 (broken) mechanical dummy switcher DCD/ DHP DCD/ DHP sensor Marker Tipp -ex Al Tape 1 Cu Tape 2 Kapton grease  ~ 0.35 T= 90ºC  ~ 0.18 T= -10ºC Arantza Oyanguren 5 8th International Workshop on DEPFET Detectors and Applications

  6. Air flow studies (vair (inlet) ~ 2m/s) - Effect of blowing air at room temperature: (corrected emmisivity) DCD/ DHP DCD/ DHP DCD/ DHP DCD/ DHP Camera position • The air flow (at room T) decreases • and homogenizes the temperature • along the detector. •  Decreases T ~ 15 C •  Max T along the ladder 18C 8C Arantza Oyanguren 6 8th International Workshop on DEPFET Detectors and Applications

  7. Air flow studies - Cooling down the end flanges with CO2 - Blowing air/N2 at different temperatures (cooled down with N2 liquid atmosphere) (vair (inlet) ~ 2m/s) 25 ºC T (ºC) Camera position (corrected emmisivity) Looking at the central region of the sensor: • Detector on: T ~ 45ºC • Effect of CO2 + air flow : T ~ 20ºC (or below) Looking at the edges: - Bumps ?? (crab legs) - With CO2 + air flow T along the ladder ~ 20ºC (!?) Arantza Oyanguren 7 8th International Workshop on DEPFET Detectors and Applications

  8. Air flow studies • Problems of IR transparence due to the • thickness of the detector: Detector on, CO2 in theendflanges, no air flow - Tipp-ex marks behind in the Cu inner ladder End flanges sensor Present setup switchers Sensor and switchers: expected about same  and behaviour (corrected emmisivity) - sensor - switchers left switchers off T(ºC) Tipp-ex marks behind End flanges Previous setup Camera position Arantza Oyanguren 8 8th International Workshop on DEPFET Detectors and Applications

  9. Air flow studies - Detector on, CO2 in theendflanges, cooled air flow - sensor - switchers T(ºC) T~10ºC Effect of IR transparence due to the thickness of the sensor (?) (corrected emmisivity) Camera position • Effect of a polycarbonatesheet (IR opaque) • behindthemechanicaldummy (i.e.between • theinner and outerladders: • A fewdegrees (~3) difference, notobserved • fortheswitchersregion, duetothereflexion • in theinnerladder, seenbythe IR camera • throughthethick sensor. Arantza Oyanguren 9 8th International Workshop on DEPFET Detectors and Applications

  10. C. Mariñas simulation Air flow studies • More realistic conditions for the • detector, set voltages so: • Sensor:  P ~ 0.5W • Switchers:  P ~ 0.5W • DCDs/DHPs:  P ~ 8W • Inner cupper ladder covered with a • polycarbonate dummy, opaque to IR Sensor T (ºC) (corrected emmisivity) Camera position Detector on Background (room T) End flanges cooled with CO2 Air flow at room T Air/N2 flow cooled [-8,-15]C Arantza Oyanguren 10 8th International Workshop on DEPFET Detectors and Applications

  11. Air flow studies - Sensor region (P~0.5W): Sensor Detector on Background (room T) End flanges cooled with CO2 Air flow at room T T (ºC) Air/N2 flow cooled [-8,-15]C Camera position • Temperature for the sensor when switching on the detector: ~ 60 C • Cooling the endflanges (CO2): T sensor< 25 C (~ room T  to check colder environment) • Blowing air at room T  T sensor < 20 C and homogenus • Blowing cooled air (-8,-15) C  T sensor < 15 C and homogeneus • Tmax along the sensor ~ 10 C (contact + remaining transparence) • For a proper T estimation from the enflanges one should have all detectors on • (but should be ok following the Karlsruhe test • (see next page)) Arantza Oyanguren 11 8th International Workshop on DEPFET Detectors and Applications

  12. Air flow studies From Karlsruhe (S. Heindl, Feb 2011) : PT1000s Silicon pieces with resistors (20W each) 120W + CO2 Cooling:  Endflange at < -10 C (most probes) Arantza Oyanguren 12 8th International Workshop on DEPFET Detectors and Applications

  13. Air flow studies - Switchers region (P~0.5W): (corrected emmisivity) Detector on Switchers Background (room T) End flanges cooled with CO2 Air flow at room T Air/N2 flow cooled [-8,-15]C T (ºC) Camera position • Only right switcher was operating • Temperature for the switchers when the detector is switched on ~ 40 C • Cooling the endflanges (CO2): T sensor ~ 20-30 C (room T  to check colder environm.) • Blowing air at room T  T sensor < 25 C and homogenus • Blowing cooled air (-8,-15) C  T sensor < 25 C and homogeneus • Small Tmax along the detector < 10 C Arantza Oyanguren 13 8th International Workshop on DEPFET Detectors and Applications

  14. Conclusions - Valencia mockup set up and understood. - At present, all tests show:  Cooled air flow decreases the ladder temperature below ~20C  Tmax along the ladder less or around 10C - Valencia activity on thermo-mechanical issues will smoothly decrease in the next year, but at present this setup may be used for any envisaged thermal test In particular: Arantza Oyanguren 14 8th International Workshop on DEPFET Detectors and Applications

  15. Mock-up • Test air flow cooling with the CO2 return Until now, air or N2 gaseous cooled by the atmosphere inside the liquid N2 Dewar (-80C) New CO2 exchanged system to cool down the air flow: 1.5m pipe coil at the CO2 return to cool down the air: Air flow temperature in the outlet ~ -5 - 0 C Arantza Oyanguren 15 8th International Workshop on DEPFET Detectors and Applications

  16. Plans • Test air flow effect in the inner ladders (mainly for the switchers) through carbon fibers Carbon fibers • Set up the new endflanges of • aluminium and/or stainless steel • (ladders better screwed, better • fixed and better thermal contact) Al samples Arantza Oyanguren 16 8th International Workshop on DEPFET Detectors and Applications

  17. Plans • Test possible vibrations in the detectors due to the air flow Capacitive Non-ContactDisplacementdetectors: ATLAS setup Arantza Oyanguren 8th International Workshop on DEPFET Detectors and Applications

  18. Backup  Dummy ladders: Polycarbonate Al Cu Heaters Resistor samples Arantza Oyanguren 18

  19. Backup  Effect of air velocity - It is enough to have a very low speed flow air to achieve a proper heat dissipation in the ladder (1WT~ 6-7ºC), (Expected behaviour from Carlos simulations) Arantza Oyanguren 19

  20. Backup  Inner ladder: heaters (3W) T (C) Air flow T~0C* Air flow T~-20C * CO2, No air flow Camera position * entering in the box; T in the CB? Arantza Oyanguren 20