An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. PowerLogic® ION8600 Monitor service entrances and substations

  2. Overview • Monitor network interties, service entrances and substations • Ideal for independent power producers and co-generation applications • Accurately measures energy bi-directionally, in both generation and stand-by modes • Gives utilities the tools to manage complex energy supply contracts • Includes commitments to power quality • Integrate with energy management and SCADA systems

  3. Revenue metering • ION8600 meters meet stringent IEC and ANSI revenue metering standards on true RMS voltage, current, and power • ANSI C12.20 0.2, Class 2, 10, & 20 • IEC 62053-22 Class 0.2S • The meters perform power quality and compliance monitoring in accordance with CBEMA/ITIC, IEEE 519 – 1992, and IEEE 1159 and monitor flicker to IEC 61000-4-15, and harmonics to IEC 61000-4-7 • Multi-user, multi-level security protects the ION8600 meter, allowing you to control and customize access for up to 16 users

  4. Modularity and communications • ION8600 meters use patented ION® technology, giving meters a modular, flexible architecture that allows for extensive user programmability • Meters address complex monitoring and control applications, and avoid obsolescence by adapting to changing needs • The ION8600 offers complete communications: fiber, Ethernet, serial, and modem • Gateway functionality simplifies communications architecture and reduces leased line or connection costs • Ports communicate with a variety of protocols (ION, DNP 3.0, Modbus RTU, Modbus TCP, MV-90) • Meters have the capability to dial out when memory is near full, and to push data through SMTP (email)

  5. Front panel characteristics Backlit LCD Display Master Reset Pinhole (located under front label) Demand Reset Switch Test Mode Button (located under front label) Alt/Enter Button Navigation Buttons

  6. Features

  7. Features

  8. Applications Use the ION8600 to: • Perform revenue metering • Monitor both co-generation and IPP • Perform energy pulsing and totalization • Monitor compliance with international standards • Analyze power quality • Control demand and power factor • Performing load curtailment • Monitor and control your equipment • Correct instrument transformers

  9. Applications • Revenue metering • Revenue approved, bi-directional measurements; monitors four quadrants • Monitor compliance with energy supply contracts • Energy suppliers: offer customized rates, flexible billing, transformer/line loss compensation, and web-based reporting • Energy consumers: audit power requirements and confirm bills • Highest revenue metering accuracy • Advanced security for 16 different users – individual passwords and rights

  10. Applications • Co-generation and IPP monitoring • Monitors bi-directional flow for both generation and stand-by modes • Energy pulsing and totalization • Use digital I/O for KYZ pulsing, end-of-interval and totalization • Compliance monitoring • Monitor compliance with international flicker and harmonics standards, IEC 61000-4-7/ 4-15

  11. Applications • Power quality analysis • Detects, records, and communicates information – nature and sequence of power quality events • Identify the cause of transients, harmonics, sags and swells • Measure percentage of system uptime in nines • Waveform recording and compliance monitoring • Monitor compliance with international flicker and harmonics standards • Diagnose and benchmark power quality on the grid and at key customer locations – allows utility personnel to make informed decisions • Analyze problems and avoid repeat interruptions

  12. Applications • Demand and power factor control • Avoid penalties – load shedding, scheduling, peak shaving and capacitor bank control • Standard demand calculation methods: block, rolling block, thermal, predicted • Measure on any instantaneous value and record peak and minimum

  13. Applications • Load curtailment • 800 user configurable channels via 50 data recorders (feature set A) • Record energy, demand, voltage, current, power quality, etc. • Implement load curtailment and distributed generation strategies • Modbus Master enables detailed facility monitoring • Identify inefficiencies; develop strategic load shedding applications • Use like an RTU to intelligently poll downstream devices such as relays or other metering products

  14. Applications • Equipment monitoring and control • Record details of equipment status • Use information from several meters to correlate system-wide events and equipment operation • Base maintenance schedules on operating history • Meter all your utilities including gas, steam, water and more

  15. Applications • Instrument transformer correction • Compensate for line loss, and power and instrument transformers • Save money and improve accuracy • Install on the low side of your transformers to compensate for less accurate equipment

  16. More Information • Visit us on the web at: • www.powerlogic.com