Communication in Substations: IEC61850 2.4 : CONCLUSION

Communication in Substations: IEC61850 2.4 : CONCLUSION. Sudhakar RAMPURKAR / AnshumanBHALLA 26th & 27th October 2009. Conclusions. For a real benefit, one needs both technical progress and international agreement to achieve the seamless communication architecture.

elana
Download Presentation

Communication in Substations: IEC61850 2.4 : CONCLUSION

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Communication in Substations:IEC618502.4 : CONCLUSION Sudhakar RAMPURKAR / AnshumanBHALLA 26th & 27th October 2009

  2. Conclusions • For a real benefit, one needs both technical progress and international agreement to achieve the seamless communication architecture. • This is exactly what IEC 61850 offers:

  3. Summary • IEC 61850 is now being used • Users’ benefits are: • Better planning in Open Electricity Market • Streamlined Specification • Simplified Design • Faster System Configuration • Securer Operation & simpler Maintenance • Safeguarded Investment • Various migration paths are available

  4. Summary • One standardised communication for all needs in the substation • Fully supports all substation automation functions comprising control, protection and monitoring • Is a global standard and the key to interoperable solutions • Architecture is future proof and facilitates future extensions, therefore it safeguards investments • Ability to reuse typical functions and/or bay designs vendor independent

  5. Summary, cont. I • Defines the availability requirements, environmental conditions and the auxiliary services of the system • Specifies the engineering process and its supporting tools, system life cycle and the quality assurance requirements • Provides engineering and maintenance support by means of the substation configuration language based on XML, i.e. documentation included • Vendor-independent engineering-data exchange

  6. Summary, cont. II • States the conformance tests to be carried out on the products • Flexibility allows optimisation of system architectures (scalable technology) • Uses commercially available hardened communication components (Industrial Ethernet) • Common use of infrastructure

  7. Market demand: Systems sales / Segmentation • IEC 61850 has become a strong requirement for Substation Automation Systems, approx. 40% • Transmission: 60% (main exceptions: US, China) • Distribution: 20% growing (linked to the IED price) • Rail: 10% growing (Europe, India starting) • Industry/ Oil & Gas: rare

  8. Market demand: Regional Strongest demand in: • India • Brazil • Central & South America • China • Middle East • Europe – various countries

  9. IEC61850 from Project Perspective • IEC61850 is very large with many service models and optional features • End users implement different combinations of these service models and the different features they provide • The protocol is still being evolved • Insufficient to simply specify IEC61850 • Necessary to state: • What features are to be used • What performance is required • Requires detailed analysis and comparison of all products in the project to ensure a good fit

  10. IEC61850 at Tendering stage • A sample of important device specifications: • Quantity of client/server associations to each IED • Quantity of peer-peer messages the device will publish • Quantity of peer-peer messages the device will subscribe to • Number of characters allowed in the device name • Service models required • Control models to be used • Implemented Logical Nodes & Optional Data Objects/Attributes • Implemented TISSUES • Where can this information be found? • Device Documentation • Substation Configuration Language Files

  11. Motivation for use of IEC61850 • Utilities expect • Interoperability of: • functions • devices • uniform system handling • harmonised general system properties • To Reduce Engineering Costs by: • Standardised information exchanges between tools • Reduction of manual entry & associated errors • Reuse of project information & configuration