Very short summary of EMMA machine status

Very short summary of EMMA machine status. Shinji Machida o n behalf of commissioning team ASTeC /STFC/RAL 24 June 2010. ALICE beam. 15 MeV kinetic energy (15.5 MeV/c momentum). 20 pC , depends on tuning. 1 Hz, can be 3 Hz. 1 bunch, can be 5 bunches. Hardware restrictions.

whitney
Download Presentation

Very short summary of EMMA machine status

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Very short summary of EMMA machine status Shinji Machida on behalf of commissioning team ASTeC/STFC/RAL 24 June 2010

  2. ALICE beam • 15 MeV kinetic energy (15.5 MeV/c momentum). • 20 pC, depends on tuning. • 1 Hz, can be 3 Hz. • 1 bunch, can be 5 bunches.

  3. Hardware restrictions • Only analog signal is available from BPM. Also only 7 pairs (E-W or N-S) at one time. • Main quadrupole magnet should be less than 260 A, enough for the present operation. • Up to 6 Hz due to the heating of septum. It is also enough. • Changing kicker amplitude shifts the kicker timing. Difficult to adjust kicker strength at crest.

  4. Injection (1) • (x, x’) at the exit of septum is not what we expected. • ~15 mm off to set angle correct and ~0.15 rad off to set position correct (number should be checked). • Septum translation and rotation can make it better, but we did not fully investigated. • Initially septum was not at design position. We found it by orbit measurement. However, it still does not give the design (x, x’).

  5. Injection (2) • Septum strength is more or less what we expected. • Kicker is only 10% or less than the design. • Small kick at kicker-1 outward. • kicker-2 kicks a beam inward. We use overshoot of kicker-2 to change the polarity. • We think we checked kicker polarity by observing beam deflection • Because (x, x’) at septum is different, kicker strength cannot be the design value.

  6. Injection (3) • Although kicker-1 kicks a beam only with a few % of design, no kicker does not make a beam go through. • The last knob which made a beam go to the end was kicker-2. • Combination of a small kicker-1 and a little stronger kicker-2 (inward) works now.

  7. Main ring • Quadrupole excitation current is a little low than the design, we think. • Nothing clear at the moment because injection was not well understood.

  8. Transverse tune • Tune measurement with 7 BPM shows • 0.12 to 0.15 for H • Around 0.13 for V • With quadrupole strength variation of -5%/+10%. • Oscillation amplitude is +/-10 mm or more. • No simple decrease vs momentum (or Q strength).

  9. Summary • EMMA is obviously running with different parameters, especially for injection, we prepared. • However, it is a set of parameters works. It was lucky we found it anyway. • Hopefully more detail report on next Thursday.