Ultra-Fast Optochemical Sensor for Express Monitoring of Oxyhydrogen Gas Mixtures in Combustion and Catalysis. Eduard G. Karpov , Civil & Materials Engineering, University of Illinois at Chicago .

ziva
Download Presentation

Eduard G. Karpov , Civil & Materials Engineering, University of Illinois at Chicago

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Ultra-Fast Optochemical Sensor for Express Monitoring of Oxyhydrogen Gas Mixtures in Combustion and Catalysis Eduard G. Karpov, Civil & Materials Engineering, University of Illinois at Chicago • Measuring the concentrations of simple gas-phase radicals (H, O, OH) is difficult due to the short lifetimes • Standard methods (paramagnetic resonance, optical and mass spectroscopy, etc.) are often slow, and insufficiently focused to be applicable to local regions of interest, microflames, nanocatalysis, and other nano applications. • There is a great potential for fast and reliable sensors with a fast response, and short repetition/measurement cycle, for measuring oxyhydrogen radicals content in gas mixtures. • “Atomic probe” procedure is developed to select an appropriate sensor core material (with dominant Eley-Rideal channel of radical recombination across the sensor range). Also, the material is selected to have luminescence properties, ZnS-Cu, ZnS-Tm, CaO-Bi, etc. Surface radical recombination invokes e-h generation with successive recombination on the luminescence centers (dopants). • The atomic probe procedure is used also to provide the etalon flow of radicals for sensor self-calibration. • Ratio of background luminescence intensity and intensity pikes due to the etalon flow is proportional to the sought concentration of radicals in the gas phase. • Ultra-short response times of up to 10–7 s, and high repetition rates of 0.5-1.0 measurement per second. • High robustness and repetitiveness of the data (O and H). • Approach excludes any spurious effects of sensor surface transformation. Approach eliminates the need for a preliminary preparation of the sensor surface. • Simplicity: etalon flow can be formed by a simple pyrolytic source (typically a platinum filament); luminescence intensity is measured by a standard photometric equipment. • The approach can be extended to the analysis of (photo)-catalytic properties of solid surfaces.

More Related