280 likes | 426 Views
Product Presentation 2007. SUPER INVERTER. SKY AIR & PACKAGED. SUPER INVERTER. Overview. 1. Model range 2. Product features - Easy Installation - Flexible Design - Energy Saving 3. Specifications. 1. Model range. MARKET. Inverter High ‘RZQ-series’ Heat pump. RZQ71CV1
E N D
Product Presentation 2007 SUPER INVERTER
SKY AIR & PACKAGED SUPER INVERTER
Overview 1. Model range 2. Product features - Easy Installation - Flexible Design - Energy Saving 3. Specifications
1. Model range MARKET Inverter High ‘RZQ-series’ Heat pump RZQ71CV1 RZQ100CV1 (1ph) RZQ125CV1 RZQ140CV1 Sky Air High end RZQ100BW1 RZQ125BW1 (3ph) RZQ140BW1 Inverter RZQ200BW (3ph) RZQ250BW (3ph) Packaged Inverter Low ‘RZQS-series’ Mainstream Non-Inverter H/P ‘RQ-series’ Non Inverter Non-Inverter C/O ‘RR-series’ Low end Non-Inverter H/P ‘REQ-series’
FHQ FCQ FBQ FCQH FFQ FDQ FAQ FUQ 1. Model Range Wide range of indoors: 8 different models in 33 different variants RZQ 71 C RZQ 100 C RZQ 125 C RZQ 140 C
1. Model Range Combination Table RZQ71/100/125/140C
FCQ-C FHQ FCQ~B FBQ FFQ FDQ FAQ FUQ 1. Model Range Wide range of indoors: 8 different models in 30 different variants RZQ200C RZQ250C
Combination Table RZQ200/250C 1. Model Range
Easy Installation Flexible Design • Flexible operation range: • => C/O operation possible • => down to -20°C in heating • => up to +50°C in cooling • EDP room application: • => R/C field setting • => I/U operation limit 11°C • Wide range of indoors: • => 8 different models • => 33 different variants • D-Bacs compatibility • Easy piping: • => max. piping length 75m • => piping length below 5m • => re-use of field piping • => flexible piping diameter • Compact design: • => same casing 4/5/6 HP • Anti-corrosion treatment • Light weight: • => 98kg for 4/5/6 HP Energy Saving • Increased efficiency: • => top COP • => DC inverter technology • => I-demand • Predicted mean value 2. Product Features Environmentally friendly • Reduction of initial charge refrigerant • Corresponding to F-gas regulation • RoHS-complaint
2. Product Features Easy Installation Piping length: • Maximum piping length = 75m • Minimum piping length = 5m • minimum allowed piping length is 3m (by field setting) H = 30m • Re-use of field piping • Flexible piping diameter • suitability of Sky Air models to existing pipes (of other brands)
Light weight: • Same weight for 100, 125 & 140 class models • Reduced weight for 100 & 125 class New RZQ 100/125/140 => 98kg RZQ 100/125 98kg 106kg 2. Product Features Easy Installation Compact design: • Dimensions • same casing for 100, 125 & 140 class models • reduced height for 100 & 125 class (-175mm) => 1.170mm * 900mm * 320mm (H*W*D)
Easy Installation Flexible Design • Flexible operation range: • => C/O operation possible • => down to -20°C in heating • => up to +50°C in cooling • EDP room application: • => R/C field setting • => I/U operation limit 11°C • Wide range of indoors: • => 8 different models • => 33 different variants • D-Bacs compatibility • Easy piping: • => max. piping length 75m • => piping length below 5m • => re-use of field piping • => flexible piping diameter • Compact design: • => same casing 4/5/6 HP • Anti-corrosion treatment • Light weight: • => 98kg for 4/5/6 HP Energy Saving • Increased efficiency: • => top COP • => DC inverter technology • => I-demand • Predicted mean value 2. Product Features Environmentally friendly • Reduction of initial charge refrigerant • Corresponding to F-gas regulation • RoHS-complaint
2. Product Features Flexible Design Wide operation range: • In cooling: -15°C / 50°C (vs. -5°C / 46°C for RZQS-series) • In heating: -20°C / 15.5°C (vs. -15°C / 15.5°C for RZQS-series) • C/O operation possible (setting to disable heating mode)
2. Product Features Flexible Design EDP room application:
D-Bacs compatibility: • Compatibility with Intelligent Manager • Compatibility with Intelligent Touch Controller 2. Product Features Flexible Design EDP room application: • EDP application is incorporated by field setting with R/C • Extended operation range till 11°CWB (indoor) in cooling mode • Minimum allowed piping length should be 3m Basic logic for EDP room
Easy Installation Flexible Design • Flexible operation range: • => C/O operation possible • => down to -20°C in heating • => up to +50°C in cooling • EDP room application: • => R/C field setting • => I/U operation limit 11°C • Wide range of indoors: • => 8 different models • => 33 different variants • D-Bacs compatibility • Easy piping: • => max. piping length 75m • => piping length below 5m • => re-use of field piping • => flexible piping diameter • Compact design: • => same casing 4/5/6 HP • Anti-corrosion treatment • Light weight: • => 98kg for 4/5/6 HP Environmentally friendly Energy Saving • Reduction of initial charge refrigerant • Corresponding to F-gas regulation • RoHS-complaint • Increased efficiency: • => reduced start-up time • => DC inverter technology • => I-demand • Predicted mean value 2. Product Features
Sine Wave DC inverter: • Increase of efficiency • High harmonics reduced => 98% electricity used 2. Product Features Energy Saving Inverter technology: • Less frequent start/stop cycles • Automatic throttle back of capacity • Start-up time down by 1/3 • Operating at partial load possible • Varying speed of compressor => Energy efficiency significantly higher
2. Product Features Energy Saving Reluctance DC compressor: • Low starting current • More stable set points Swing Compressor Scroll Compressor Suction Swing bush Scroll Low Pressure Part Ref. Gas Discharge Reluctance DC Motor High Pressure Part The piston which the blade and the roller unified • Class 71 • Friction & leaks suppressed • Improved energy saving • Class 100, 125 & 140 • Easier superheat control • Improved performance
DC Fan motor: • Improvements in operating efficiency (especially during low speed) • Improvement in energy efficiency (at low velocities in particular) 2. Product Features Energy Saving 4 Neodymium magnets: • More powerful than ferrite types • Better performance • Higher energy efficiency Energy cost savings ↑ FEATURES BENEFITS Increased torque for same consumption Neodymium magnets Optimized version of DC motor Additional torque / same energy consumption
2. Product Features Energy Saving I-demand function: • Operation: difference actual/predefined power consumption minimized • Max. power consumption limited to 80%~40% of rated power input • KRP58M51 (optional adaptor) required Power Consumption (kW) Maximum power consumption can be easily controlled: The maximum capacity is maintained while the power consumption is kept at a certain level. The set value can be freely changed. Time Setting way External Input Demand 1~3 External Control Adaptor (Optional PCB) <Manual> Contact Changeover <Auto> When the function is turn on, Demand 1 starts as default setting (Setting on the optional PCB)
Cooling 2. Product Features Energy Saving Predicted Mean Value: High Always comfortable Always comfortable Auto Operation Mode: Controls room temperature in accordance with feeling temperature. Cost-efficient operation Cost-efficient operation Room Temperature Normal Operation Mode: Controls room temperature at a designated temperature. Over capability Shortage of capability Over capability Set point 23°C [Morning] Chilly [Night] Chilly [Day] Muggy [Morning] Chilly [Day] Muggy [Night] Chilly Unnecessary cooling Unnecessary cooling Low Energy saving Energy saving
2. Product Features Energy Saving Predicted Mean Value: High Always comfortable Heating Auto Operation Mode: Controls room temperature in accordance with feeling temperature. Cost-efficient operation Normal Operation Mode: Controls room temperature at a designated temperature. Over capability Room Temperature Shortage of capability Shortage of capability Set point 21°C [Night] Cold [Morning] Cold [Day] Hot Unnecessary heating Low Energy saving
Remarks • No change in option list • Not suited: • => for EDP room applications • => for piping length < 5m 2. Product Features RZQ200/250C • Energy saving => high efficiency => power limit setting • Easy piping: • => max. piping length 100m • => re-use of field piping • => flexible piping diameter • Light weight: • => 198kg for 8 & 10 HP • Possibility of C/O operation • Night quiet operation
Thank you for your attention. Questions?