Some MKI observations during fill 1794 -1859 MD 25ns Wk43

Some MKI observations during fill 1794 -1859 MD 25ns Wk43. V. Baglin (1/11/11 ). CERN TE-VSC, Geneva. 1 . 2. MKI LSS2. MKI LSS8. Fill 1794. Fill 1794 : 50ns_1308b_108bpi_13inj_scrub At 450 GeV. Fill 1794 – MKI LSS2. Fill 1794 : 50ns_1308b_108bpi_13inj_scrub 450 GeV

Download Presentation

Some MKI observations during fill 1794 -1859 MD 25ns Wk43

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Some MKI observations during fill 1794 -1859 MD 25ns Wk43 V. Baglin (1/11/11) CERN TE-VSC, Geneva 1. 2.

  2. MKI LSS2

  3. MKI LSS8

  4. Fill 1794 • Fill 1794 : 50ns_1308b_108bpi_13inj_scrub • At 450 GeV

  5. Fill 1794 – MKI LSS2 • Fill 1794 : 50ns_1308b_108bpi_13inj_scrub • 450 GeV • Solenoids ON • MKI : 3 -> 5 10-10 mbar

  6. Fill 1794 – MKI LSS2 - intermodule • Fill 1794 : 50ns_1308b_108bpi_13inj_scrub • 450 GeV • Solenoids ON • Pressure blue beam larger than red beam • Pressure increases from Q5L2 to Q4L2 • Blue : 4 -> 6 10-9 mbar • Red : 4 -> 11 10-10 mbar

  7. Fill 1794 – MKI LSS8 • Fill 1794 : 50ns_1308b_108bpi_13inj_scrub • 450 GeV • Solenoids ON • MKI : 5 10-10 mbar

  8. Fill 1794 – MKI LSS8 - intermodule • Fill 1794 : 50ns_1308b_108bpi_13inj_scrub • 450 GeV • Solenoids ON • No strong difference between two beams • Blue : 6 -> 24 10-10 mbar • Red : 1 -> 2 10-9 mbar

  9. Fill 1859 • Fill 1859 : 50ns_1092b+1small_1042_35_1008_108bpi

  10. MKI2 - Tank • 50ns_1092b+1small_1042_35_1008_108bpi • With B2 and B1+B2, highest pressure in tank MKI close to Q5L2 • Pressure is lower than for MKI8 case

  11. MKI2 – intermodules line B1 • 50ns_1092b+1small_1042_35_1008_108bpi • With B2, almost no pressure increase, whereas it increase with B1+B2

  12. MKI2 – intermodules line B2 • 50ns_1092b+1small_1042_35_1008_108bpi • With B2, almost no pressure increase, whereas it increase with B1+B2 • The copper chamber does not produce significant pressure increase due to electron cloud

  13. MKI8 - Tank • 50ns_1092b+1small_1042_35_1008_108bpi • With B2 and B1+B2, high pressure in tank MKI

  14. MKI8 – intermodules line B2 • 50ns_1092b+1small_1042_35_1008_108bpi • With B2, high pressure in inter-module at extremity of tank with highest pressure • The highest pressure in on the right of the tank • Pressure ratio at extremities between 2 to 5

  15. MKI8 – intermodules line B1 • 50ns_1092b+1small_1042_35_1008_108bpi • With B2, high pressure in inter-module at extremity of tank with highest pressure • The highest pressure in on the right of the tank • The pressure is lower than inter-module B2 • Pressure ratio at extremities equal 7

  16. MKI8 – intermodules right of tank 2 • 50ns_1092b+1small_1042_35_1008_108bpi • With B2, high pressure in inter-module at right extremity of tank with highest pressure • The highest pressure in on the right of the tank • The pressure ratio is 2 to 3 • The ceramic chamber seems to have the • highest pressure increase

  17. Fill 2251 • MD25 ns, wk 43 • Fill 2251 : 2100/1020 b spaced by 25 ns and 925 ns, 72bpi