470 likes | 928 Views
Ex isolating spark gaps Examples of use. Ex isolating spark gap EXFS 100; Part No. 923 100 Application environment. Isolating spark gaps or protective spark gaps are supposed to establish a galvanic isolation of electric parts of the installation, which are not connected with
E N D
Ex isolating spark gap EXFS 100; Part No. 923 100Application environment • Isolating spark gaps or protective spark gaps are supposed to establish a galvanic isolation of electric parts of the installation, which are not connected with • each other under normal operating conditions. • - Specific applications: • for establishing a galvanic isolation of insulatingflanges and insulated couplings (e.g. fuel pipes) • Cathodic corrosion protection of tanks • Cathodic corrosion protection of pipelines • Lightning equipotential bonding of gas pressure regulation stations • Assembly: • Isolating spark gaps can be mounted between the parts of the installation to be bridged by means of brackets or connectors. When mounting isolating sparks, the shortest possible cable length should be used as long cables increase the danger of inductive voltages putting unnecessary stress on the isolation. EXFS 100 14.01.08 / 5242e
Ex isolating spark gap EXFS 100; Part No. 923 100Application EXFS 100 14.01.08 / 5238e
Cathodic corrosion protection of tank installatins EXFS 100 building earth – ~ + EXFS 100 14.01.08 / 5300e
Insulating flange of fuel or product pipelines EXFS 100 insulating flange building earth EXFS 100 14.01.08 / 5301e
Insulating flange of fuel or product pipelines EXFS 100 insulating flange EXFS 100 – ~ insulating flange + EXFS 100 14.01.08 / 5302e
Insulating flange of fuel or product pipelines EXFS 100 insulating flange EXFS 100 gas pressure regulator insulating flange EXFS 100 14.01.08 / 5303e
Installation of EXFS 100 EXFS 100 EXFS 100 minimum distance 2 cm pipeline pipeline EXFS 100 14.01.08 / 5304e
Installation of EXFS 100 electric actuator, e.g. MOV (motor operated valve) cathodic corrosion protection 16 mm² Cu Insulating flange ground earth-termination system EXFS 100 14.01.08 / 5305e_a
Installation of EXFS 100 detail electric actuator, e.g. MOV (motor operated valve) EXFS 100 cathodic corrosion protection 16 mm² Cu Insulating flange ground earth-termination system EXFS 100 14.01.08 / 5305e_b
Installation of EXFS 100 cathodic corrosion protection detail electric actuator, e.g. MOV (motor operated valve) EXFS 100 16 mm² Cu Insulating flange ground earth-termination system EXFS 100 14.01.08 / 5305e_c
Installation of EXFS 100 < 300 mm arrangement as required CCP - side loop loop Reference: Eon Ruhrgas EXFS 100 14.01.08 / 5306e
Installation of EXFS 100 Type A Installation of EXFS 100 if several pipelines are run closely in parallel and insulating units installed directly side by side. Type B loop If possible the isolating spark gaps shall be installed symmetrically between the pipelines. Reference: Eon Ruhrgas EXFS 100 14.01.08 / 5307e
Installation of EXFS 100 Type C EXFS 100 14.01.08 / 5308e
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_a
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_b
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_c
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_d
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_e
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_f
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_g
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_h
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_i
Ex isolating spark gaps EXFS 100 (KU)Application Reference: Schwelm Anlagentechnik GmbH, Austria EXFS 100 14.01.08 / 5317e_j