1 / 17

M1H Transfer Function

M1H Transfer Function. Georg Gassner, March 6 th , 2013. Measurement Setup. Seismometer. Buttkicker. Vibco. Seismometer. M1H Background Noise – X-Axis. M1H Background Noise – Y-Axis. Vibrating the Stand. 43.6Hz. Buttkicker. Applied Freq. vs. X-Axis Sensor on Top. 3µm Amplitude.

dior
Download Presentation

M1H Transfer Function

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. M1H Transfer Function Georg Gassner, March 6th, 2013

  2. Measurement Setup Seismometer Buttkicker Vibco Seismometer LCLS-II Phys. Meeting / March 6, 2013

  3. M1H Background Noise – X-Axis LCLS-II Phys. Meeting / March 6, 2013

  4. M1H Background Noise – Y-Axis LCLS-II Phys. Meeting / March 6, 2013

  5. Vibrating the Stand 43.6Hz Buttkicker LCLS-II Phys. Meeting / March 6, 2013

  6. Applied Freq. vs. X-Axis Sensor on Top 3µm Amplitude 31nm Amplitude 3nm Amplitude LCLS-II Phys. Meeting / March 6, 2013

  7. AppliedFreq. vs. Y-Axis Sensor on Top 3nm Amplitude LCLS-II Phys. Meeting / March 6, 2013 Y- motion mostly caused by crosstalk due to sensor placement off axis

  8. Vibrating the Floor Vibco LCLS-II Phys. Meeting / March 6, 2013

  9. AppliedFreq. vs. X-Axis Sensors 31nm Amplitude 3nm Amplitude LCLS-II Phys. Meeting / March 6, 2013

  10. Applied Freq. vs. Y-Axis Sensors 3nm Amplitude 3nm Amplitude LCLS-II Phys. Meeting / March 6, 2013

  11. Result - Transfer Function LCLS-II Phys. Meeting / March 6, 2013 • Y-axis vibration 1=1 • X-axis response varies by the induced frequency.

  12. Construction Activity test Aug 1st 2012 Integrated raw data: • M1H top 1.0µm @ 24Hz (27; 29) • M2H top 0.1µm @ 20Hz • M1H floor 0.3µm @ <20Hz Statistics @ 23Hz LCLS-II Phys. Meeting / March 6, 2013 Road Header

  13. Construction Activity test Aug 1st 2012 Integrated raw data: • M1H top 0.1µm @ 30Hz (24; 45) Statistics @ 30Hz LCLS-II Phys. Meeting / March 6, 2013 Concrete Drill

  14. Outlook LCLS-II Phys. Meeting / March 6, 2013 • Mirror yaw measurements: • No measurement device available to measure yaw movement with 1µrad resolution @100Hz sampling rate. • Solution: Use x-ray beam to measure effect of mirror vibration in FEH. • Install vibration device and seismometer sensors on PAMM of 3/20. • Measure construction activity: • Installed sensors in BTH today. • Construction activities and vibration measurements on 3/19.

  15. Construction Equipment Activities – Sensor Placement QUM1 &2 QEM1 & 2 QT41, 42, 43 Construction Activities

  16. Sensors on QUM#1 & #2 and QEM#1 & #2 LCLS-II Phys. Meeting / March 6, 2013

  17. Sensors on QT41, QT42 & QT43 LCLS-II Phys. Meeting / March 6, 2013

More Related