American Conference of Governmental Industrial Hygienists. Bioaerosols Assessment and Control Editor: Janet Macher, Sc.D., M.P.H. 01/1999. ACGIH Guidelines. Minimum Visible Fungal Growth. Remediation .. Maintenance Staff Personnel PPE …………. N95 & Gloves Work Area ….. Unoccupied
E N D
American Conference of Governmental IndustrialHygienists BioaerosolsAssessment and ControlEditor: Janet Macher, Sc.D., M.P.H. 01/1999
ACGIH Guidelines Minimum Visible Fungal Growth Remediation .. Maintenance Staff Personnel PPE …………. N95 & Gloves Work Area ….. Unoccupied Adjacent ……. N/A Areas
ACGIH Guidelines Minimum Visible Fungal Growth Containment .. None needed; use dust suppression methods Damaged …… Sealed in bags Materials Follow-up …… HEPA-vacuum & Damp Cleaning wipe/mop HVAC ……….. NA
ACGIH Guidelines Moderate Visible Fungal Growth Remediation .. Trained Personnel Personnel PPE …………. N95, Safety Glasses, full body covering & gloves Work Area ….. Unoccupied Adjacent ……. Remove immuno- Areas compromised individuals
ACGIH Guidelines Moderate Visible Fungal Growth Containment .. Poly enclosure & negative pressure Damaged …… Sealed in bags Materials Follow-up …… HEPA-vacuum & Cleaning damp wipe/mop HVAC ……….. NA
ACGIH Guidelines Extensive Visible Fungal Growth Remediation .. Trained Personnel Personnel PPE …………. N95, safety glasses, full body covering & gloves Work Area ….. Unoccupied Adjacent ……. Remove immuno- Areas compromised individuals
ACGIH Guidelines Extensive Visible Fungal Growth Containment .. Use critical barriers, negative pressure & full - scale poly containment Damaged …… Sealed in bags Materials Follow-up …… HEPA-vacuum & damp Cleaning wipe/mop HVAC ……….. NA