1 / 28

JAK DZIAŁA OGÓLNIE V OP MARTWA STREFA / SZEROKOŚĆ IMPULSU DOKŁADNOŚĆ I ROZDZIELCZOŚĆ

Samouczek Time Domain Reflectometry (TDR) (Reflektometrii w aspekcie czasowym). JAK DZIAŁA OGÓLNIE V OP MARTWA STREFA / SZEROKOŚĆ IMPULSU DOKŁADNOŚĆ I ROZDZIELCZOŚĆ. TDR korzysta z. Teorii linii transmisyjnej , zasad odbicia impulsu W celu wykrycia zmian impedancji wzdłuż kabla :.

garron
Download Presentation

JAK DZIAŁA OGÓLNIE V OP MARTWA STREFA / SZEROKOŚĆ IMPULSU DOKŁADNOŚĆ I ROZDZIELCZOŚĆ

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Samouczek Time Domain Reflectometry (TDR) (Reflektometrii w aspekcie czasowym) JAK DZIAŁAOGÓLNIEVOPMARTWA STREFA / SZEROKOŚĆ IMPULSUDOKŁADNOŚĆ I ROZDZIELCZOŚĆ

  2. TDR korzysta z. . . Teorii linii transmisyjnej, zasad odbicia impulsu W celu wykrycia zmian impedancjiwzdłuż kabla: TDR przesyła impulsy wzdłuż metalowych kabli Cechy takie, jak uszkodzenia są odzwierciedlane w TDR TDR mierzy czas potrzebny, aby wysłany impuls wrócił do nadajnika i zamienia go na długość wzdłuż kabla

  3. TDR przedstawia informację w formie śladu. Odległość od uszkodzenia

  4. Impedancja kabla • Impedancja kabla składa się z rezystancji, indukcjii pojemnościzawartej w kablu • Odbite impulsy są spowodowane zmianami w impedancji.

  5. TDR ŚladyCo oznaczają ….. Odbiornik Obwód otwarty Podłączenie boczne Obwód zamknięty Łączenie Przeciek wody Rozgałęzienie i zejście Łączenie mokre Łączenie o wysokiej oporności Krzyżówka

  6. Ogólnie • TDR może mierzyć odbicia spowodowane serią impedancji od paru do paruset Ohmów • TDR może również mierzyć odbicia spowodowane impedancją przeciekową do paruset Ohmów • Uszkodzenia powodujące wysoką impedancję pomiędzy przewodnikami, lub przewodnikiem do ziemi wymagają mostka dostępnego z RB6000

  7. Prędkośćpropagacji(VOP) • Jest to miara, jak konstrukcja kabla (izolacja) oddziałowuje na prędkość, z którą impuls TDR przemieszcza się wzdłuż kabla. • Prędkość światła w wolnym powietrzu = 300m/ms • Jednostki • m/µs, ft /µs • Lub ułamekPRĘDKOŚĆ IMPULSU W KABLU PRĘDKOŚĆ ŚWIATŁA

  8. Prędkośćpropagacji • Impulsy rozchodzą się z różnymi prędkościami w różnych kablach z różnymi prędkościami, tak, jak piłka przemieszcza się przez różne płyny • Typ izolacji i geometria przekroju kabla mają wpływ na prędkość impulsu

  9. Prędkośćpropagacji VOP….. • VOP rozdzielczość • Zwykle VOP przedstawiany jest jako ułamek, wprowadzona do TDR z dokładnością 2, lub 3 miejsc po przecinku. • Np. przy 0.667, niedokładność związana z odchyleniami, to ± 0.15% • VOP adokładność • Zmieniająca się do paru procent z powodu tolerancji wykonania kabli i ich starzenia

  10. Mity doczycące prędkości propagacji • Nie mogę użyć TDR jeżeli prędkość propagacji jest nieznana” • Nie jest to prawdą • możnazmierzyć próbkę kabla o znanej długości (na przykład parę metrów) i obliczyć prędkość propagacji, tak, że wynik pomiaru = konkretna długość • można dokonać pomiaru określającego relacje między pomiarem z jednej strony i z drugiej strony i użyć miernika kółkowego, aby określić miejsce wystąpienia • możnaużyć typowych liczb dla typu kabla, np.. 0,667 dla pary skręcanej

  11. Szerokość impulsu i martwa strefa • SZEROKOŚĆ IMPULSU: • Impulsy rozprzestrzeniają się i redukują a amplitudzie, gdy przemieszczają się wzdłuż kabli • Kable, które przekazują wyższe częstotliwości, (na przykład kncentryczne) powodują mniejsze rozproszenie • Szersze impulsy lokalizują uszkodzenia na większych dystansach

  12. Mit: Szeroki impuls jest mniej dokładny od wąskiego To nieprawda • TDR wykorzystuje wznoszącą krawędź transmitowanego impulsu w celu lokalizacji impulsu • Pomiar wykonywany jest ze wznoszącej krawędzi The measurement is done from the rising edge of the transmit pulse to the leading edge of the reflected feature • The subsequent information / shape gives additional information about the fault and not its distance

  13. Pulse width / dead zone…..

  14. Pulse width and dead zone • Narrower pulses will allow you to see consecutive faults more easily but don’t travel as far as wider ones • Fix the first fault before looking for other ones.

  15. Pulse width / dead zone…..

  16. Pulse width / dead zone….. • DEAD ZONE Dead zone is the area under the transmit pulse OR under the reflected pulse • Pulses are attenuated by the first fault, so additional faults are difficult to see • Repair the first fault, then the cable is tested for any other faults • Dead zone is generally not important

  17. Myth: Dead zone affects fault location ability • This is not true • Dead zone under transmit pulse can be accommodated by : • Extra length of cable • Use of balance control • Use a narrow pulse • Use of differential mode • Dead zone under reflection can be accommodated by: • Fixing the first fault and then look again • Use a narrower pulse

  18. Differential (Line 1 - Line 2) shows difference between good and bad cable pairs, e.g. fault reflections

  19. Pulse width / dead zone….. • Balance control • Only changes display • Mixes opposite polarity pulse to cancel transmitted pulse on display • Shows faults within transmitted pulse

  20. Pulse Width & Dead zone... • The displayed reflections vary in width dependent on output pulse width • Reflections from faults may be hidden within a wide “dead zone” • A wide output pulse may affect the ability to distinguish closely spaced events.

  21. TDR accuracy and resolution….. • TDR measures the time taken for a pulse to travel and return from a fault reflection • TDR then calculates the distance to the fault Calculate using • measured time to fault • speed of pulse in cable(VOP, Propagation Velocity Factor)

  22. Accuracy and resolution... Time measurement • Modern TDRs use digital techniques • Sample returned (input) signals at intervals in order • to measure the time to a fault • Sample Resolution (time interval between samples) • affects accuracy: e.g. if samples taken every 100ns, then accuracy can never be better than ± 100ns

  23. Accuracy and resolution… Time measurement • Sample Accuracy - accuracy (regularity) of interval between samples • If samples are taken every 100ns, are they actually taken every 100ns, not every 110ns • Cursor Setting Resolution • The resolution of the screen (number of pixels) determines the resolution with which the cursor can be set • In practice, on a modern TDR, time measurement, accuracy and resolution are better than they need to be.

  24. Accuracy and resolution… • Fault Location Accuracy is the ability to accurately locate • the distance to the fault • Fault Resolution is the ability to resolve consecutive faults • Narrow pulses are good • But FIX THE FIRST FAULT then LOOK AGAIN

  25. Using TDR measurements… • Have a distance from the TDR • However, cables do not run in straight lines • Cable pairs in multicore cables are laid up in spirals inside the sheath • The pairs in the middle are shorter • than the pairs closer to the sheath

  26. Using TDR measurements… • Records showing installed cable positions can be • approximate, • completely wrong • non-existent • use a locator to trace the cable • The major source of error in using a TDR • is translating the distance on the TDR • to a distance on installed cable. • This also applies to other measurement techniques, e.g. bridges • Use a locator to trace the cable

  27. Summary….. • Use cable recordsand a locatorto confirm a fault location - you need to know the lie of the cable • Operator interpretation of the start of the fault can be a source of error • A narrow pulse is no more accurate than a wide one • You can use a TDR if you don’t know the VOP • ‘Dead zone’ does not make using a TDR difficult • Fix the first fault first and then look for others

  28. Model RB6000