An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. I DIGITAL AXLE COUNTER G.D.CHANDOLIA

  2. WHAT IS AXLE COUNTER ? • IT IS MEANS FOR DETECTION OF TRAIN ON A TRACK. • IT IS HAVING TWO SETS OF TRANSDUCERS & A PROCESSSOR. • ONE SET IS INSTALLED AT THE ENTRANCE OF LENGTH OF TRACK WHICH COUNTS IN. • ANOTHER SET IS INSTALLED AT THE EXIT OF LENGTH OF TRACK WHICH COUNTS OUT. • THE PROCESSOR PROCESS THE COUNTS IN & COUNTS OUT AND CLEAR THE LINE IF THEY ARE EQUAL & SHOWS OCCUPIED IF THEY ARE NOT EQUAL.

  3. ADVANTAGES OF AXLE COUNTERS • MONITORS VERY LONG TRACK SECTIONS • IMMUNE TO BALLAST RESISTANCE • INSENSITIVE TO TEMPERATURE VARIATION • INDEPENDENT OF TYPE & QUALITY OF RAILS, SAND FORMATION & WATER LOGGED TRACKS • IMMUNE TO TRACTION RETURN CURRENTS

  4. APPLICATION OF AXLE COUNTERS • TRACK CIRCUITING OF BERTHING TRACKS • TRACK CIRCUITING OF POINT ZONE TRACKS • VERIFICATION OF COMPLETE ARRIVAL OF TRAIN • INTERMEDIATE BLOCK SIGNALLING • AUTOMATIC SIGNALLING • TRAIN ACTUATED WARNING DEVICE

  5. TYPES OF AXLE COUNTERS

  6. NEED OF DIGITAL AXLE COUNTERS DEFICIENCIES IN ANALOG AXLE COUNTERS • TROLLEY SUPPRESION TRACK CIRCUIT RELAY CONTACTS. • NO DIAGNOSTIC FEATURES. • REQUIRES INTERPHASE EQUIPMENT WITH OTHER • TRANSMISSION MEDIA. • ACCESSORIES SUCH AS RELAYS, CABLECONDUCTORS, • SPACE & EQUIPMENTS AS WELL AS MAINTENANCE IS MORE • NO. OF HARDWARES FOR FIXING TRACK DEVICES • INTERFERENCE OF 5 KHz. SIGNAL WITH HARMONICS.

  7. SINGLE SECTION DIGITAL AXLE COUNTERS(SSDAC)-BLOCK DIAGRAM

  8. SSDAC – SYSTEM COMPONENTS • AXLE DETECTOR – 2 NOS. • SSDAC COUNTING UNITS – 2 NOS. • RESET BOX – 1 NO. (COMMON RESETTING) – 2 NOS. (INDEPENDENT RESETTING) • VITAL RELAY - QS3 ( 24V) 2 NO. • POWER SUPPLY ARRANGEMENT - 24 V DC(2 Nos.) • COMMUNICATION & SIGNALLING CABLES AS PER LOCATION • TROLLEY SUPPRESSION TRACK CIRCUIT - 2 Nos.

  9. AXLE DETECTORS • FREQUENCY OF 21KHz & 23KHz TX/RX COILS ARE USED. • WEB TYPE AXLE DETECTORS • DEFLECTOR BRACKET ASSEMBLY • COMPATIBLE WITH 90R,52 KG & 60 KG RAIL PROFILES • DETECTION OF ALL WHEELS WITH WHEEL DIA > 400 MM

  10. VIEW OF COUNTING UNIT

  11. COUNTING UNIT – FRONT VIEW

  12. COUNTING UNIT - FUNCTIONS • GENERATION OF CARRIER SIGNAL FOR TX COILS • DEMODULATION OF SIGNAL FROM RX COILS • GENERATION OF VALID PULSES • COUNT THE PULSES TO COMPUTE THE NUMBER OF PASSING WHEELS • EXCHANGE & COMPARISON OF COUNTS BETWEEN TWO SSDAC UNITS • GIVING A VITAL RELAY OUTPUT • ERROR CHECKING AND DISPLAY

  13. COUNTING UNIT- OTHER FEATURES • DESIGNED AS PER CENELEC STANDARDS OF HIGHEST SAFETY INTEGRITY LEVEL 4 (SIL-4). • BASED ON FAIL SAFE PRINCIPLE • BASED ON 2 OUT OF 2 LOGIC • ALL THE CARDS ARE OF EXTENDED SINGLE EURO SIZE(220mmX100mm) • MOTHERBOARD FOR INTER CARD CONNECTIONS • PHYSICAL DIMENSIONS 300X133X300mm • FIRST TIME DEVELOPED INDIGENOUSLY BY CEL & RDSO. • IMPORT SUBSTITUTE. • CENELEC-Committee European de Normalisation Electro technique

  14. COUNTING UNIT - CONSTIUENTS • CARD 1 SIGNAL CONDITIONING CARD FOR 21 KHz • CARD 2 SIGNAL CONDITIONING CARD FOR 23 KHz • CARD 3 MICRO CONTROLLER LOGIC & ERROR DISPLAY CARD • CARD 4 MICRO CONTROLLER LOGIC & ERROR DISPLAY CARD • CARD 5 EVENT LOGGER CARD(OPTIONAL) • CARD 6 MODEM CARD • CARD 7 RELAY DRIVER CARD • CARD 8 DC-DC CONVERTOR CARD

  15. SIGNAL CONDITIONING CARD - FUNCTIONS • GENERATION OF CARRIER SIGNALS OF 21 KHz OR OF 23 KHz FOR TX COILS • DEMODULATION OF RECEIVER COIL SIGNAL OF 21 KHz OR OF 23 KHz FROM RX COILS • ADJUSTMENT OF RECEIVER SIGNAL WITH POTENTIOMETER • GENERATION OF WHEEL PULSE • PULSE SHAPING • TROLLEY SUPPRESSION TRACK CIRCUIT • GENERATION OF SUPERVISORY SIGNAL

  16. SIGNAL CONDITIONING CARD – SALIENT FEATURES • THE CARRIER SIGNALS OF 21 KHz OR OF 23 KHz FOR TX COILS ARE GENERATED WITH OUTPUT VOLTAGE AS 30V TO 40V rms & FREQUENCY VARIATION OF 20 KHz. • THERE IS A LEVEL DETECTOR CIRCUIT WHICH CHECKS THE LEVEL OF RECEIVER COIL OUTPUT • TO ADJUST THE LEVEL OF DEMODULATED SIGNAL FROM RX COIL, POTENTIOMETER HAS BEEN PROVIDED. • TO INHIBITE COUNTING DUE TO TROLLEYS , TRACK CIRCUIT CONTACTS ARE CONNECTED • PULSE SHAPER CIRCUIT HAS BEEN PROVIDED BY USING HYBRIDS.

  17. SIGNAL CONDITIONING CARD – INDICATIONS LED INDICATIONS ARE PROVIDED FOR • OSC OK ON OSCILLATOR WORKING PROPERLY • LD OK ON LD WORKING PROPERLY • PULSE OK ON PULSE SHAPER WORKING PROPERLY • TP CONNECTED/ ON TRACK CIRCUIT CONNECTED TPR PICKED UP UNDER NORMAL CONDITION ,THE LED WILL BE GLOWING.

  18. MICRO CONTROLLER LOGIC CARD- FUNCTIONS • TWO IDENTICAL CARDS TO HAVE 2 OUT OF 2 LOGIC • MONITOR & RECEIVE PULSE SIGNAL • OUTPUT PULSE SIGNAL TO OTHER MICRO CONTROLLER LOGIC CARD • DETECT THE DIRECTION OF MOVEMENT • COUNTING THE WHEELS PASSSING OVER DETECTOR • SUPERVISION OF AXLE DETECTORS, PRESENCE OF CARDS • CODE MESSAGE PACKETS FOR TRANSMISSION TO REMOTE COUNTING UNIT

  19. MICRO CONTROLLER LOGIC CARD- FUNCTIONS( CONT.) • DECODE MESSAGE PACKETS RECEIVED FROM REMOTE COUNTING UNIT • DETERMINE THE NUMBER OF AXLES IN THE SECTION • CONTROL & SUPERVISE THE STATUS OF VITAL RELAY. • GENERATION OF SYSTEM ERROR CODES • GENERATION OF CLOCK • RECEIVING THE RESET COMMAND FROM MODEM CARD

  20. MICRO CONTROLLER LOGIC CARD- SALIENT FEATURES • MICRO CONTROLLER IS BASED ON STANDARD 89C51 • RS232 COMPATIBLE SERIAL PORT FOR MODEM CONNECTIVITY • 1OK BYTE ON CHIP FLASH ROM FOR PROGRAM STORAGE • 256 BYTE ON CHIP RAM • PARALLEL PORTS FOR ADDRESS /MODE INPUT, PULSE INPUTS & VITAL RELAY OUTPUT • LED DISPLAY FOR COUNT PROGRESS/ ERROR DISPLAY • LED INDICATORS FOR SECTION STATUS

  21. MICROCONTROLLER LOGIC BOARD – INDICATIONS LED INDICATIONS ARE PROVIDED FOR • CLEAR ON CLEAR CONDITION • OCCUPIED ON OCCUPIED CONDITION • ERRORS BLOCK 1 2 1 2 3 4 4 8 5 6 10 20 7 8 40 80

  22. LIST OF ERRORS

  23. LIST OF ERRORS (CONTD…)

  24. MODEM CARD- FUNCTIONS • IT PROVIDES SIGNAL CONVERSION FROM DIGITAL TO ANALOG AND VICE-VERSA AS PER CCITT V.21 STANDARD. • IT IS USED FOR COMMUNICATION BETWEEN TWO COUNTING UNITS WHICH IS IN THE FORM OF DATA PACKETS • DATA PACKETS CONSISTS OF COUNT CHANGE INFORMATION, COUNT UPDATE INFORMATION, POWER ON/RESET INFORMATION & ERROR INFORMATION IF ANY. • IT INTERFACES WITH SERIAL RS232C PORT OF BOTH MICRO CONTROLLER LOGIC CARDS. • MULTIPLEX RS232C INPUTS & SELECTS ONE CHANNELS.

  25. MODEM CARD- SALIENT FEATURES • MULTIPLEXES THE TWO SERIAL PORTS • AMD 7911 FSK MODEM CHIP • V.21 MODE OF OPERATION (2 WIRE) • 300 BAUD RATE TRANSMISSION • SETTING IN ORIGINATOR(ENTRY UNIT) & ANSWERER(EXIT UNIT) MODE. • SWITCH SELECTABLE GAINS IN RECEIVE & TRANSMIT PATH • LED INDICATORS FOR SECTION STATUS

  26. MODEM CARD – INDICATIONS LED INDICATIONS ARE PROVIDED FOR • TX FLASHING TRANSMITTING THE SIGNAL • RX FLASHING RECEIVING THE SIGNAL • MODE OFF NOT IN NETWORKING • CD ON CARRIER IS DETECTED

  27. RELAY DRIVER CARD- FUNCTIONS • IT CHECKS & GENERATES THE VITAL RELAY DRIVE OUTPUT. • THIS OUTPUT IS USED TO DRIVE FAIL SAFE VITAL RELAY • THE OUTPUT IS GENERATED ONLY WHEN THE SELF COUNT & REMOTE COUNTS ARE MATCHED AND EQUAL • ALSO THE SUPERVISORY SIGNALS ARE NORMAL AT BOTH LOCATION.

  28. RELAY DRIVER CARD- SALIENT FEATURES • DUAL CLOCK CHECKING CIRCUIT • OPTO ISOLATOR CIRCUIT • VITAL RELAY DRIVE OUTPUT CIRCUIT • LED INDICATORS FOR CLOCK. CLEAR PULSE RELAY DRIVER OUTPUT

  29. RELAY DRIVER CARD – INDICATIONS LED INDICATIONS ARE PROVIDED FOR • MLB1 CLEAR COUNTS ARE BALANCED • MLB1 CLOCK FLASHING SECTION IS CLEAR • MLB2 CLEAR COUNTS ARE BALANCED • MLB2 CLOCK FLASHING SECTION IS CLEAR • RELAY DRIVE ON 24V DC AVAILABLE

  30. DC-DC CONVERTOR CARD- FUNCTIONS • IT RECEIVES 24V BATTERY/IPS INPUT. • IT GENERATES 5V,12V,24V OUTPUT WITH COMMON GROUND • A SEPERATE 15V WITH ISO GROUND IS ALSO GENERATED • IT GENERATES LED INDICATION FOR BOTH INPUT & OUTPUT SUPPLY.

  31. DC-DC CONVERTOR CARD- SALIENT FEATURES • INPUT RANGE IS 18V TO 30V • OUTPUT RATING 5V –2A, 12V –200mA, 24V –300mA & 15V-100mA • LOAD REGULATION 0.1% & 0.5% • INPUT & OUTPUT PROTECTED AGAINST SHORT CIRCUIT • INPUT REVERSE POLARITY PROTECTION • LOW RIPPLE, EFFICIENCY BETTER THAN 50%, NO OVERSHOOT/UNDERSHOOT.

  32. DC-DC CONVERTOR CARD – INDICATIONS LED INDICATIONS ARE PROVIDED FOR • 5V ON PRESENCE OF 5V • 12V ON PRESENCE OF 12V • 24V ON PRESENCE OF 24V • 15V ON PRESENCE OF 15V OFF INDICATES FAILURE

  33. RESETTING SYSTEM- FUNCTIONS • IT IS REQUIRED TO MAKE THE SYSTEM NORMAL IN CASE AXLE COUNTER HAS FAILED/SWITCHING ON POWER SUPPLY. • IT IS DONE WITH THE HELP OF SM’s RESET BOX. (PREPARATORY RESET) • AS PER SAFETY REQUIREMENT, TO NORMALISE THE AXLE COUNTER, THE FIRST TRAIN SHALL BE PILOTED IN THE SECTION AFTER RESETTING TO REGISTER BALANCE OF COUNTS IN THE SYSTEM

  34. RESET BOX- SALIENT FEATURES • IT IS HAVING LED INDICATION FOR SECTION STATUS • IT IS HAVING SM’S KEY ACTUATOR & RESET BUTTON • COUNTER FOR RECORDING NO. OF RESET • PREPARATORY RESET RELAY (PPR1) MINITURE RELAY • INPUT VOLTAGE 24V DC • 24V TO 48V DC- DC CONVERTOR • 48V IS USED FOR RESETTING

  35. RESET BOX – INDICATIONS LED INDICATIONS ARE PROVIDED FOR • CLEAR ON SECTION IS CLEARED • OCCUPIED ON SECTION IS OCCUPIED • PREPARATORY RESET ON PREPARATORY RESET STATE • POWER ON ON PRESENCE OF 24V OFF INDICATES FAILURE