340 likes | 371 Views
CE3503 Environmental Engineering. Water Treatment. Dr. Martin T. Auer MTU Department of Civil & Environmental Engineering. Drinking Water Treatment Objectives. Potable: safe to drink - may be consumed with low risk of immediate or long term harm. Palatable: pleasant to taste.
E N D
CE3503 Environmental Engineering Water Treatment Dr. Martin T. Auer MTU Department of Civil & Environmental Engineering
Drinking Water Treatment Objectives Potable: safe to drink - may be consumed with low risk of immediate or long term harm. Palatable: pleasant to taste
U.S. EPA Standards National Primary Drinking Water Regulations Microorganisms Disinfectants & Disinfection Byproducts Inorganic Chemicals Organic Chemicals Radionuclides Enforceable
U.S. EPA Standards National Primary Drinking Water Regulations Microorganisms Viruses: hepatitis A, gastroenteritis Bacteria: cholera, dysentery, legionellosis, typhoid Protozoa: Giardia and Cryptosporidium Turbidity: standard is 1 NTU; microorganism contamination is associated with turbidity; particles also shield microorganisms from agents of disinfection. Indicator organisms: standard for microbial contamination is based on E. coli , a species of bacteria originating from animal or human fecal material. Most strains of E. coli are not pathogenic, but their presence indicates the presence of fecal material and thus, potentially, pathogenic microbes. No E. coli may be present in finished drinking water.
U.S. EPA Standards National Primary Drinking Water Regulations Chemicals Inorganic: arsenic, cadmium, copper, lead, mercury, nitrate Organic: herbicides (e.g. atrazine), insecticides (methoxychlor), industrial residues (e.g. polychlorinated biphenyls, dioxin) Radionuclides: and particles, radium, uranium MCLs: Maximum Contaminant Levels
U.S. EPA Standards National Primary Drinking Water Regulations Disinfectants Chlorine Chlorine dioxide Chloramines Disinfectants & Disinfection Byproducts Trihalomethanes
U.S. EPA Standards Secondary Drinking Water Regulations Cosmetic Effects (tooth color, excess fluoride) Total Dissolved Solids (chloride, sulfate) Taste, Odor, Color Non-Enforceable (federally)
U.S. EPA Standards National Primary Drinking Water Regulations Microorganisms Viruses: hepatitis A, gastroenteritis Bacteria: cholera, dysentery, legionellosis, typhoid Protozoa: Giardia and Cryptosporidium Turbidity: standard is 1 NTU; microorganism contamination is associated with turbidity; particles also shield microorganisms from agents of disinfection. Indicator organisms: standard for microbial contamination is based on E. coli , a species of bacteria originating from animal or human fecal material. Most strains of E. coli are not pathogenic, but their presence indicates the presence of fecal material and thus, potentially, pathogenic microbes. No E. coli may be present in finished drinking water.
Drinking Water Process Train Basic treatment for turbidity and pathogens
Particle Settling Velocities Source: Vesilind & Morgan Stokes Law Thus, the small, clay particles settle extremely slowly.
Coagulation + + Particle populations are stable because their net negative charge repels one another. Chemicals such as alum are added to neutralize the negative charge and destabilize the particle populations and allow them to come together, i.e. coagulate. Addition of the chemical occurs in a flash mix of 1-3 minutes where the chemical dissolves and mixes with the raw water. + + + + + + + + +++ +++ +++ +++ +++ +++ +++
Flocculation The alum reacts with calcium bicarbonate naturally present in most waters to form a precipitate or floc, aluminum hydroxide. Destabilzied smaller particles can be attracted to the floc or simply swept up by the larger particles (sweep floc) as they settle and removed from the system. Flocculation proceeds through a slow mix of 10-30 minutes.
Sedimentation Sedimentation takes place over a period of 1-4 hours.
Disinfection Chlorination Thus above HOCl dominates below pH 7.5 and OCL- dominates above pH 7.5 sorption
Disinfection Design Chick’s Law sorption The Surface Water Treatment Rule Requires a 4-log or 99.99% removal and
Disinfection The Surface Water Treatment Rule Requires a 4-log or 99.99% removal Design Ct = concentration, time It = irradiance, time
Disinfection Residual
Disinfection Disinfection By-products (DBPs) Formed through reaction of chlorine and natural organic matter (NOM) e.g. trihalomethanes such as chloroform, Design – reduce NOM through pre-oxidation with ozone.
Hardness Ca2+, Mg2+ Adding lime and soda ash, Ca(OH)2, Na2CO3 Precipitates, CaCO3, Mg(OH)2
Granular Activated Carbon The most commonly used adsorbent is granular activated carbon (GAC). These irregular particles, 0.2-5 mm in diameter, are a char of carbon material (wood or coal). They are ‘activated’ or made more porous by exposure to steam at high temperature. Activated carbon has 1000 m2 of adsorbing surface area per gram (~ 1 teaspoon) or equivalent to that of a 40 acre farm in one handful! Source: Sontheimer et al. 1988 Source: Chemviron Carbon Source: Millenium Inorganic Chemicals
The Adsorption Process Organic chemicals are typically removed from a water supply prior to distribution through the process of adsorption: the physical-chemical attraction of a solid material for a chemical in solution. In adsorption, the chemical being adsorbed is termed the adsorbate and the solid to which it sorbs is the adsorbent. Effluent stream Influent stream
6 (mg/L) 4 2 Concentration 0 0 2 4 6 8 Time (d) … tendency to sorb For adsorption to be effective, the chemical must sorb strongly. Poorly soluble (hydrophobic) compounds (e.g. the components of gasoline) adsorb more strongly than highly soluble (hydrophilic) compounds (e.g. table salt). Poorly sorbed Strongly sorbed
… application in water treatment In drinking water treatment, adsorption with GAC is accomplished using a packed bed column. The untreated water is introduced at the top of the column and trickles down through the GAC. Contaminants are removed en route and clean water emerges at the bottom of the column. In application, columns 6 feet in diameter and 30 feet in height are not uncommon. Carbon Bed GAC columns
… column operation Water flows thru the column and contaminants are adsorbed. With time, the GAC becomes saturated (sorption capacity is reached) and contaminants exit the bed (breakthrough). The exhausted carbon must then be replaced. Cin exhaustion Cout Ceq breakthrough
Asbestos/Arsenic/Metals Removal Sorption with Ferric sulfate: asbestos, arsenic, cadmium, chromium, copper, lead, mercury, molybdenum, selenium, silver Coagulation with Alum: asbestos, nickel, uranium
Ultrafiltration polypropylene fiber 300 µm ID 500 µm OD
Ultrafiltration 0.2 µm nominal pore size
permeate flow epoxy seal Ultrafiltration raw water in
Ultrafiltration contaminants banks of fiber bundles backwashing
Ultrafiltration contaminants backwashing
Home Water Treatment Reverse osmosis unit (salt) Softening by ion exchange (hardness)
Home Water Treatment • Three step process: • sieve and bottom filter – rust, sand, turbidity • activated carbon filter – chlorine, color and SOCs • ion exchange resin – metals Bottled Water: $8 /gallon Tap Mount: $0.25 / gallon Municipal: $0.0015 / gallon Achieves 99.99% removal of Giardia and Cryptosporidium cysts, but does not remove all pathogenic organisms.