An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CE3503 Environmental Engineering Water Treatment Dr. Martin T. Auer MTU Department of Civil & Environmental Engineering

  2. Drinking Water Treatment Objectives Potable: safe to drink - may be consumed with low risk of immediate or long term harm. Palatable: pleasant to taste

  3. London 1854

  4. Philadelphia

  5. Milwaukee Cryptosporidium 1993 - 403,000 – 104 Dead

  6. U.S. EPA Standards National Primary Drinking Water Regulations Microorganisms Disinfectants & Disinfection Byproducts Inorganic Chemicals Organic Chemicals Radionuclides Enforceable

  7. U.S. EPA Standards National Primary Drinking Water Regulations Microorganisms Viruses: hepatitis A, gastroenteritis Bacteria: cholera, dysentery, legionellosis, typhoid Protozoa: Giardia and Cryptosporidium Turbidity: standard is 1 NTU; microorganism contamination is associated with turbidity; particles also shield microorganisms from agents of disinfection. Indicator organisms: standard for microbial contamination is based on E. coli , a species of bacteria originating from animal or human fecal material. Most strains of E. coli are not pathogenic, but their presence indicates the presence of fecal material and thus, potentially, pathogenic microbes. No E. coli may be present in finished drinking water.

  8. U.S. EPA Standards National Primary Drinking Water Regulations Chemicals Inorganic: arsenic, cadmium, copper, lead, mercury, nitrate Organic: herbicides (e.g. atrazine), insecticides (methoxychlor), industrial residues (e.g. polychlorinated biphenyls, dioxin) Radionuclides:  and  particles, radium, uranium MCLGs: Maximum Contaminant Level Goals – level below which there is no know or expected risk to health. Allow a margin of safety and are not enforceable. MCLs: Maximum Contaminant Levels – highest level allowed in drinking water. MCLs are enforceable and are set as close to MCLGs as feasible using BAT, taking into account economic considerations.

  9. U.S. EPA Standards National Primary Drinking Water Regulations Disinfectants Chlorine Chlorine dioxide Chloramines Disinfectants & Disinfection Byproducts Trihalomethanes

  10. U.S. EPA Standards Secondary Drinking Water Regulations Cosmetic Effects (tooth color, excess fluoride) Total Dissolved Solids (chloride, sulfate) Taste, Odor, Color Non-Enforceable (federally)

  11. U.S. EPA Standards National Primary Drinking Water Regulations Microorganisms Viruses: hepatitis A, gastroenteritis Bacteria: cholera, dysentery, legionellosis, typhoid Protozoa: Giardia and Cryptosporidium Turbidity: standard is 1 NTU; microorganism contamination is associated with turbidity; particles also shield microorganisms from agents of disinfection. Indicator organisms: standard for microbial contamination is based on E. coli , a species of bacteria originating from animal or human fecal material. Most strains of E. coli are not pathogenic, but their presence indicates the presence of fecal material and thus, potentially, pathogenic microbes. No E. coli may be present in finished drinking water.

  12. Drinking Water Process Train Basic treatment for turbidity and pathogens

  13. Particle Settling Velocities Source: Vesilind & Morgan Stokes Law Thus, the small, clay particles settle extremely slowly.

  14. Coagulation + + Particle populations are stable because their net negative charge repels one another. Chemicals such as alum are added to neutralize the negative charge and destabilize the particle populations and allow them to come together, i.e. coagulate. Addition of the chemical occurs in a flash mix of 1-3 minutes where the chemical dissolves and mixes with the raw water. + + + + + + + + +++ +++ +++ +++ +++ +++ +++

  15. Flocculation The alum reacts with calcium bicarbonate naturally present in most waters to form a precipitate or floc, aluminum hydroxide. Destabilzied smaller particles can be attracted to the floc or simply swept up by the larger particles (sweep floc) as they settle and removed from the system. Flocculation proceeds through a slow mix of 10-30 minutes.

  16. 1x107 Alum Sweep Floc 8x106 6x106 Particle Volume Distribution (m3/mL) 4x106 2x106 0 0.0 0.4 0.8 1.2 1.6 log of particle diameter measured in m Courtesy Dr. Desmond Lawler, University of Texas

  17. Sedimentation Sedimentation takes place over a period of 1-4 hours.

  18. Filtration Water is filtered until significant head loss is experienced, then the filter is backwashed.

  19. Disinfection Chlorination HOCl dominates below pH 7.5 and OCL- dominates above pH 7.5 HOCl is the stronger disinfectant and thus it is best to chlorinate at pH<7.5 sorption

  20. Disinfection – The CT Relationship The Surface Water Treatment Rule Requires a 4-log or 99.99% removal Design Chick’s Law sorption

  21. Disinfection The Surface Water Treatment Rule Requires a 4-log or 99.99% removal Design Ct = concentration, time It = irradiance, time

  22. Disinfection Residual

  23. Disinfection Disinfection By-products (DBPs) Formed through reaction of chlorine and natural organic matter (NOM) e.g. trihalomethanes such as chloroform, Design – reduce NOM through pre-oxidation with ozone.

  24. Iron and Manganese

  25. Hardness Primarily Ca2+, Mg2+ Limestone: calcium carbonate, CaCO3 Dolomite: calcium magnesium carbonate, CaMg(CO3)2 The limestone formation underlying much of Miami, Florida

  26. Lime – Soda Ash Process Adding lime, Ca(OH)2 Adding soda ash, Na2CO3

  27. Granular Activated Carbon The most commonly used adsorbent is granular activated carbon (GAC). These irregular particles, 0.2-5 mm in diameter, are a char of carbon material (wood or coal). They are ‘activated’ or made more porous by exposure to steam at high temperature. Activated carbon has 1000 m2 of adsorbing surface area per gram (~ 1 teaspoon) or equivalent to that of a 40 acre farm in one handful! Source: Sontheimer et al. 1988 Source: Chemviron Carbon Source: Millenium Inorganic Chemicals

  28. The Adsorption Process Organic chemicals are typically removed from a water supply prior to distribution through the process of adsorption: the physical-chemical attraction of a solid material for a chemical in solution. In adsorption, the chemical being adsorbed is termed the adsorbate and the solid to which it sorbs is the adsorbent. Effluent stream Influent stream

  29. 6 (mg/L) 4 2 Concentration 0 0 2 4 6 8 Time (d) … tendency to sorb For adsorption to be effective, the chemical must sorb strongly. Poorly soluble (hydrophobic) compounds (e.g. the components of gasoline) adsorb more strongly than highly soluble (hydrophilic) compounds (e.g. table salt). Poorly sorbed Strongly sorbed

  30. … application in water treatment In drinking water treatment, adsorption with GAC is accomplished using a packed bed column. The untreated water is introduced at the top of the column and trickles down through the GAC. Contaminants are removed en route and clean water emerges at the bottom of the column. In application, columns 6 feet in diameter and 30 feet in height are not uncommon. Carbon Bed GAC columns

  31. … column operation Water flows thru the column and contaminants are adsorbed. With time, the GAC becomes saturated (sorption capacity is reached) and contaminants exit the bed (breakthrough). The exhausted carbon must then be replaced. Cin exhaustion Cout Ceq breakthrough

  32. Asbestos/Arsenic/Metals Removal Sorption with Ferric sulfate: asbestos, arsenic, cadmium, chromium, copper, lead, mercury, molybdenum, selenium, silver Coagulation with Alum: asbestos, nickel, uranium

  33. Membrane Processes

  34. Ultrafiltration polypropylene fiber 300 µm ID 500 µm OD

  35. Ultrafiltration 0.2 µm nominal pore size

  36. permeate flow epoxy seal Ultrafiltration raw water in

  37. Ultrafiltration contaminants banks of fiber bundles backwashing

  38. Ultrafiltration contaminants backwashing

  39. Home Water Treatment Reverse osmosis unit (salt) Softening by ion exchange (hardness)

  40. Home Water Treatment • Three step process: • sieve and bottom filter – rust, sand, turbidity • activated carbon filter – chlorine, color and SOCs • ion exchange resin – metals Bottled Water: $8 /gallon Tap Mount: $0.25 / gallon Municipal: $0.0015 / gallon Achieves 99.99% removal of Giardia and Cryptosporidium cysts, but does not remove all pathogenic organisms.