An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ASHRAE Headquarters ASHRAE Headquarters Succeeding in Sustainability

  2. 40% of all energy in the United States is used by buildings.

  3. Only 2% of buildingstock is built new each year.

  4. The greatest opportunity to change energy consumption in the built environment is through modification of existing buildings.

  5. In 2005, ASHRAE formed a plan to renew its headquarters building in Atlanta. The project was completed in June 2008: ASHRAE succeeded in creating a healthy, productive and sustainable building, ensuring a sustainability showcase for years to come. • 34,000 ft2 • Total cost of 6.2million

  6. Building Excellence • A- in As Designed category of ASHRAE’s Building Energy Quotient program • Recipient of ENERGY STAR® • Awarded LEED Platinum in New Construction in Version 2.2

  7. Goals of Renewal • Deliver a healthy and productive workplace • Demonstrate commitment to sustainability • Create a living lab • Provide a learning center

  8. Commitment to Sustainability The many resource-conserving features of the ASHRAE Headquarters building resulted in tremendous savings: • Total annual water consumption has been reduced by 67% • A 54% reduction in site energy use intensity • Thermal comfort satisfaction improved from 18% to 33% • Indoor air quality satisfaction improved from 26% to 77%

  9. Energy Efficiency As part of the “living lab” concept, the building uses three separate HVAC systems The first floor is conditioned for heating and cooling using a variable refrigerant flow (VRF) system with heat recovery. The system includes five inverter driven, outdoor DX heat pumps, three ductless fan coil units, twenty-one branch selector boxes, and twenty-two ducted fan coil units operating on HFC 410A refrigerant (System Capacity 32 tons (113 KW) total).  

  10. Energy Efficiency As part of the “living lab” concept, the building uses three separate HVAC systems The second level is conditioned using fourteen two-stage, 27-EER variable-speed ground-source heat pumps, with a geothermal field of 12 400-foot-deep wells, and a closed-loop piping system.

  11. Energy Efficiency As part of the “living lab” concept, the building uses three separate HVAC systems The pump shown is part of the ground source heat pump system and it helps to harness energy stored near the surface of the earth to provide high-efficiency heating and cooling for the 14 individual zones on the second level.

  12. Energy Efficiency As part of the “living lab” concept, the building uses three separate HVAC systems The third system is a dedicated outdoor air system (DOAS), which provides 6,000 cubic feet per minute (CFM) of outside air to the first and second floors for ventilation (30% more than required) and incorporates dual stage air-to-air heat recovery desiccant heat wheels, variable speed supply and exhaust fans, DX cooling coils and MERV 13 air filters

  13. Local and centralized control hardware precisely manage the conditioned space allowing for total comfort, energy efficiency, and remote monitoring Energy Efficiency A Web-based direct digital control (DDC) system provides integrated control of HVAC equipment from multiple manufacturers, maintaining a comfortable, healthful and energy efficient working environment.

  14. High-efficiency lighting lowers lighting power use by 25 to 35% and sensors automatically adjust usage based on occupancy Energy Efficiency The parking lot luminaireswere updated to reduce light pollution emanating from the site.

  15. ASHRAE has extensively isolated load types and sub-metered the building so the information can be monitored and used in the future. Energy Efficiency The Building Automation System (BAS) provides a user interface for the living lab project, allowing researchers around the world to monitor performance and extract data for research purposes.

  16. ASHRAE used the enhanced commissioning process from ASHRAE Guideline 0 to ensure that the building performs according to its design.

  17. Renewable Energy A 20-kilowatt photovoltaic solar panel array on the roof produces electricity during daylight hours, which in turn is sold to the local electrical utility at a premium price. If this power was instead used to power the building, it is estimated it would offset 8% of the total building load.

  18. Water Efficiency • Annual water consumption has been reduced by 64% by using high-efficiency low-flow toilets, waterless urinals and solar water preheat of domestic hot water. • The landscaping has also been configured to eliminate the need for irrigation.

  19. Indoor Environmental Quality Building envelope enhancements allow for increased daylighting throughout the building

  20. Indoor Environmental Quality The building employs low-emitting materials, such as furnishings and carpet, throughout to reduce indoor air contaminants that are odorous, irritating or harmful to the comfort and well-being of occupants.

  21. Indoor Environmental Quality A comfortable thermal environment that supports theproductivity and well-being of all building occupants is provided by adhering to the requirements of ASHRAE Standard 55.

  22. ReducedEnvironmental Impact ASHRAE has increased the amount of vegetated open space by 45% above local code requirement to conserve valuable water, reduce run-off, reduce heat island effects and help provide a more attractive site.

  23. ReducedEnvironmental Impact The heat island effect from the roof and parking lot have been reduced using a cool white reflective roof membrane with a solar reflectance index (SRI) of 78 and a protective crust over half of the parking lot pavement with a SRI of 32. .

  24. ReducedEnvironmental Impact Site runoff has been reduced by 34% and the rate of runoff by 30%. Runoff water is reduced by the green roof areas and naturally filtered of pollutants a bioswale system, which gradually releases water back into the storm water system to prevent overload.

  25. Reduced Environmental Impact ASHRAE is demonstrating how to extend the lifecycle of existing buildings, conserve resources, and reduce waste by retaining more than 90% of the original structure and envelope.

  26. Reduced Environmental Impact ASHRAE protected the environment during the renovation process: • Diverted more than 90% of the construction waste away from landfills and incinerators • 22% of total value of project materials made from recycled content • Selected refrigerants and HVAC&R systems to minimize ozone depletion and global warming

  27. Transportation ASHRAE is actively encouraging alternative and fuel-efficient transportation means for its staff and guests: • on-site bike storage, showers and changing rooms • dedicated parking for low-emitting & fuel-efficient vehicles • more than 5% of parking spaces reserved for carpools

  28. ASHRAE Guidance Followed • Energy efficiency: Standard 90.1-2004 • Thermal comfort: Standard 55-2004 • Ventilation: Standard 62.1-2004 • Energy in existing buildings: Standard 100-2006 • Commissioning: Guideline 0-2005 • HVAC&R system commissioning: Guideline 1-2006

  29. Thank You! ASHRAE would like to thank the following companies and individuals who helped make this project possible • ASHRAE Foundation • Automated Logic Corp. • ClimateMaster • Daikin • Georgia Power/Southern Company • Trane • Aircuity • Interface FLOR • Mark Brandli, design principal/Richard Wittshiebe Hand • Commissioning & Green Building Solutions (CxGBS) Inc. • Dynamic Air Quality Solutions • EBTRON Inc. • Bill and Margaret Harrison • Northwrite • PolyCon • Thermal Gas Systems Inc. • U.S. Green Building Council