1 / 28

Fixation externe mono latérale des fractures distales du fémur Etude critique à partir de 18 cas

Fixation externe mono latérale des fractures distales du fémur Etude critique à partir de 18 cas. P. Mertl Amiens. Epidémiologie. Registre AO 1980-1989 2165 fractures (10 %des fractures du fémur) 70% > AVP, haute énergie, chez sujets jeunes 29% ouvertes.

jared
Download Presentation

Fixation externe mono latérale des fractures distales du fémur Etude critique à partir de 18 cas

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fixation externe mono latérale des fractures distales du fémurEtude critique à partir de 18 cas P. Mertl Amiens

  2. Epidémiologie • Registre AO 1980-1989 • 2165 fractures (10 %des fractures du fémur) • 70% > AVP, haute énergie, chez sujets jeunes • 29% ouvertes The epidemiology of fractures of the distal femur O. Martinet, Injury, 2000

  3. Complications • Infection et pseudarthrose infectée: 13% • Pseudarthrose aseptique: 14% • Raideur: 14% • Arthrose (cal vicieux…): 50% Table ronde SOFCOT 1988

  4. Type de fixation externe

  5. Fixateur mono-latéralTêtes en « T » • Genou fléchi…..(FL) • Table ordinaire • Os spongieux peu dense • Proximité capsule • Bras de levier de la jambe

  6. Matériel et méthodes: 18 cas • 16 hommes, 2 femmes • Age moyen: 36 ans • Etiologies: • AVP 2 roues: 3 • AVP auto: 7 • AVP piéton: 2 • Chute lieu élevé: 3 • Chute banale: 1 • Autre: 2

  7. Matériel et méthodes Types de fractures 9 Fractures A3 4 Fractures A2 5 Fractures C2

  8. Matériel et méthodes • Ouverture cutanée: 14/18 • Type I : 3 • Type II : 9 • Type III: 2 • Fermeture après parage • 1 lambeau • 1accourcissement transitoire • 3 fiches diaphysaires, 3 fiches épiphysaires • Ostéosynthèse associée:5 cas (vis,cerclages)

  9. Type A2 Consolidation à 5 mois Bon résultat fonctionnel (0°-100°)

  10. Type A3

  11. Type C2

  12. Résultats • Consolidation per-primam: 12 cas • Appui complet à 3 mois • Dynamisation à 4 mois • Délai de consolidation: 6,5 mois • Consolidation avec greffe d’emblée: 3 cas • Pseudarthrose: 3 cas • 2 greffes FE en place • 1 greffe avec ostéosynthèse par plaque

  13. Type A3: greffe vissée

  14. Résultats • Complications: • Ecoulement sur fiches: 4 cas • Aucune arthtrite • Démontage fixateur: 2 cas imposant une reprise • Cal vicieux: 10 cas • Varus > 10° : 8 • Valgus > 10°: 2 • Mobilités: 0°-15°- 90° (70° -120°) 6 ostéotomies secondaires

  15. Type A2

  16. Type A2 Ostéotomie de soustraction Varus > 10°

  17. Résultats globaux • Aucun excellent résultat • 5 bons • 10 moyens • 3 mauvais 72% 44% de reprise…….!

  18. Discussion • Peu de séries publiées • 60 cas recensés sur 4 publications: 1-Supracondylar fractures of the femur treated by external fixation, J.L. Marsh,J. Orthop. Trauma, 2000 2- Treatment of isolated complex distal femoral fractures by external fixation, F. Ali, M. Saleh, Injury, 2000 3-Treatment of comminuted intra-articular distal femur fractures with limited internal and external tensionned wire fixation, J. Hutson, J. Orthop. Trauma, 2000 4-Ilizarov fixator for severly comminuted supracondylar and intercondylarfractures of the distal femur, M. Arazi, JBJS, 2001

  19. Fixateur mono-latéral • Ali, Injury, 2000 • 13 fr. ouvertes • Aucune infection • 1 pseudarthrose • Consolidation: 6 mois • Bonnevialle, RCO, 2005 • 19 fr. distales • Pseudarthrose: 38% • Infection: 8% • Fr. itératives: 15%

  20. Facteurs pronostiques Risque de pseudarthrose Risque d’infection Evaluation of contributing factors on deep infection and non-union for open femoral fractures T. Noumi, Injury, 2005

  21. Risque d’arthrite • Incidence: • Tibia distal: 1 à 5% • Tibia prox.: 2 à 5% • Fémur distal: 6% • Rarement II aire à 1 plaie articulaire • Souvent II aire à 1 infection / fiche ou broche (Weiner, JOT, 1995 - Marsch, JBJS, 1995) (Wyrsch, JBJS, 1996: multiplanaires) (Hutson, JOT, 2000: FE hybrides)

  22. Enraidissement Surtout marqué au genou: Perforation ligt. collatéraux Perforation fascia-lata / fémur distal: Mise en place genou en flexion Majoré par 1 fixation trans-articulaire

  23. Alternatives: nombreuses… • FE fémoral: indication d’exception Performances méca. médiocres Déplacement secondaires Lésions artérielles, larges ouvertures, Polytraumatisés (Hutson, JOT, 2000 ) • Bonne vascularisation régionale: ECM antéro ou rétrograde Ostéosynthèse / plaques Risque infectieux identique (Cieslik, Orthop. Trauma. Rehab., 2007)

  24. Alternatives: nombreuses… Distal femoral fractures: A review of fixation methods, M. C. Forster, Injury, 2006

  25. Fixateur temporaire? • Fixation trans-articulaire • Fiches non transfixiantes • Antérieures et latérales • Ostéosynthèse IIaire • 5 à 21 jours Parekh, JOT, 2008 • 16 fr. ouvertes • Consolidation: 92% • Infections: 16% • Flexion: 100°

  26. Place du FE hybride? • Rarement en urgence • 2ème temps d’1 FE trans-articulaire • 2 anneaux distaux • Broches olivaires Zlowodski, JOT, 2006 • 5 séries FE hybrides • 68 fr. fémorales distales • Pseudarthrose: 7,5% • Infection: 4,3%

  27. Take Home Message ! • FE: Indications d’exception / fractures ouvertes • Stade I et II: • Ostéosynthèse interne en urgence ou différée • Privilégier les interventions retardées….surtout sur stade II • Stade III et IV: • Fixateur externe mono-latéral • Temporaire? Fractures récentes de l’extrémité inférieure du fémur, Ph. Chiron, Conférence d’Enseignement de la SOFCOT, 1995 Fixation externe des fractures métaphyso-épiphysaires du MI P. Mertl, Conférence d’Enseignement de la SOFCOT, 2009

  28. Take home message! Open fractures: principes of management, R. M. Smith, Current Orthopaedics, 1999

More Related