80 likes | 212 Views
Team 3 Piano Glove. Reliability and Safety Analysis Carolyn McMican Daniel Stein Jonathan Kuntzman Mihir Shah. Reliability Analysis - Overview. 4 main components considered Glove Micro - PIC24FJ128GA310 Base Micro - PIC18F87K90 3.3V Power Supply - CC3-0503SR-E
E N D
Team 3Piano Glove Reliability and Safety Analysis Carolyn McMican Daniel Stein Jonathan Kuntzman Mihir Shah
Reliability Analysis - Overview • 4 main components considered • Glove Micro - PIC24FJ128GA310 • Base Micro - PIC18F87K90 • 3.3V Power Supply - CC3-0503SR-E • 5V Power Supply - VEFT1-SMT
FMECA – Overview • One high criticality failure mode • Glove PS fail short or input capacitors fail short • Causes heating of glove and high stress on the batteries • Detected through loss of power LED illumination, loss of function, and heating of glove • Glove power supply has internal 5A fuse • No protection against short of input capacitors