Pixel nSQP Wires order in progress. Presented by David Nelson djn@slac.stanford.edu. Specification work. Discussed wire order specifications with MWS Wire. The resistance specification became an issue due to both twisting and elongation changes the values.

kieu
Download Presentation

Pixel nSQP Wires order in progress

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pixel nSQPWires order in progress Presented by David Nelson djn@slac.stanford.edu

  2. Specification work • Discussed wire order specifications with MWS Wire. • The resistance specification became an issue due to both twisting and elongation changes the values. • I suggested that we require a material certification that provides traceability to actual material used. This was rejected by MWS. • We used “CERTS” for NASA projects. • MWS suggested we accept a test report for each type of wire pair. I think this is about all we can expect from MWS wire. It seems we are the first to ask for acceptance tests of this level. • MWS has not updated their web site with NEMA MW1000-2008 revision. There is some discrepancies between the specifications listed below and the MWS web site. They are, however, minor. • The test reports need minor modifications. • I suggest we modify the specifications to the following line items:

  3. 28 AWG twisted pair specifications • 28 AWG • (1) 28 AWG solid CCA twisted pair, 2 TPI +/- 10% • (2) Insulation is QML. • (3) Material - The core alloy is aluminum 1350 (EC grade) and the cladding alloy is oxygen free copper 102. • (4) CCA bare wire is 10% copper by volume. • (5) Bare wire diameter, 0.0126 plus/minus 0.0001inch • (6) Outer diameter - with insulation, 0.0156 inch < OD < 0.0167 inch [0.396mm < OD < 0.424mm] • (7) One wire colored red, one wire colored green • (8) Resistance prior to twisting, 101.5-105.6 Ohms per 1000 feet @ 20 Degrees C • Reference http://www.mwswire.com/pdf_files/mws_tech_book/clad_metals.pdf • (9) Spool length, 1000 ft -0/+50 ft, No splices in spool. • Spool lengths are to be agreed upon between buyer and seller. • (10) Total length ?? • (11) Test report shall be provided that conforms to the above specifications.

  4. 36 AWG twisted pair specifications • 36 AWG • (1) 36 AWG solid copper twisted pair, 4 TPI +/- 10% • (2) Insulation is QML. • (3) Material - Copper conductor is ETP 99.90% minimum, UNSC11000 • (3) Bare wire diameter, 0.0049 inch < OD < 0.0051 inch • (4) Outer diameter - with insulation, 0.0065 inch < OD < 0.0074 inch [0.165mm < OD < 0.188mm • (5) One wire colored red, one wire colored green • (6) Resistance prior to twisting, 398.7-431.9 Ohms per 1000 feet @ 20C. • Reference http://www.mwswire.com/awgsearch2.asp • (7) Spool length, 1000 ft -0/+50 ft, No splices in spool. • Spool lengths are to be agreed upon between buyer and seller. • (8) Total length ?? • (9) Test report shall be provided that conforms to the above specifications.

  5. MWS Wire Test Reports