CONSEIL INTERNATIONAL DES GRANDS RESEAUX ELECTRIQUES INTERNATIONAL COUNCIL ON LARGE ELECTRIC SYSTEMS. COMITATO NAZIONALE ITALIANO. 41 ma Sessione Generale Cigre Parigi, 27 agosto – 1 settembre 2006 Comitato di studio C4 System Technical Performance

lani
Download Presentation

COMITATO NAZIONALE ITALIANO

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CONSEIL INTERNATIONAL DES GRANDS RESEAUX ELECTRIQUES INTERNATIONAL COUNCIL ON LARGE ELECTRIC SYSTEMS COMITATO NAZIONALE ITALIANO 41ma Sessione Generale Cigre Parigi, 27 agosto – 1 settembre 2006 Comitato di studio C4 System Technical Performance A. Ardito (CESI) C.A. Nucci (Univ. di Bologna) Membro italiano Chairman of SC C4 Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  2. Sintesi della ‘Technical Session’ dello SC C4 • Partecipanti: oltre il centinaio • Osservazioni generali: due ‘special reporter’ S. Pack e S. Maruvada, ognuno con due ‘preferential subject’. • Pack (PS1 e PS2) – 11 lavori con 27 domande • PS1: 9 lavori, 20 domande – 17 ‘contributions’ a 14 domande, nessun ‘contribution’ a 6 domande – 14 ‘spontaneous contributions’, • PS2: 2 lavori, 7 domande – 8 ‘contributions’ a 7 domande, nessun ‘contribution’ a 1 domanda –9 ‘spontaneous contributions’ • Maruvada (PS3 e PS4) – 13 lavori con 31 domande • PS3: 6 lavori con 15 domande – 11 ‘contributions’ a 10 domande, nessun ‘contribution’ a 5 domande – some ‘spontaneous contributions’ • PS4: 7 lavori con 16 domande – 24 ‘contributions’ a 15 domande, nessun ‘contribution’ a 1 domanda –some ‘spontaneous contributions’ Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  3. Sintesi della ‘Technical Session’ dello SC C4 • PS1 - Performance of Power Systems against Lightning-Originated Disturbances – Main Conclusions • Flashover rate of transmission lines  risultati di calcolo vanno interpretati con cautela. In certi casi anche i risultati del campo richiedono attenzione • Lightning data (Ng, Ipeak etc,.)  indispensabili per gli studi relativi alla ‘lightning performance’. Le loro distribuzioni dipendono dalle tecnologie di misura (torri di rilevamento, LLS, CFC, etc.), dal periodo di osservazione, dalla zona in cui vengono rilevati:  uso ragionato e da parte di esperti. • Per la risposta dei sistemi di distribuzione la discussione ha riguardato essenzialmente il trasformatore ed i modelli relativi in regime transiorio. Non è disponibile un modello generalmente accettato, e si auspica una maggiore collaborazione tra gruppi di ricerca e costruttori. • Esigenza di studi più accurati per pervenire al migliore coordinamento dell’isolamento delle linee di distribuzione, soprattutto per quanto concerne la loro risposta alle fulminazioni. Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  4. Sintesi della ‘Technical Session’ dello SC C4 • PS2 - Impact of Monitoring and Diagnostics on Insulation Coordination – Main Conclusions • Sono argomento di interesse crescente in tutte le parti del mondo e per tutti i componenti dei sistemi di potenza • I risultati dipendono fortemente dalla adeguatezza del M+D system (MDS). • E’ necessaria la definizione chiara delle interfacce tra i MDS e i componenti monitorati, così come tra i MDS dei vari costruttori/fornitori. La durata dell’osservazione è un punto critico • Il coordinamento dell’isolamento può essere migliorato/ottimizzato solo in seguito lunghi periodi di osservazione. Oggi sono ancora applicati fattori di sicurezza. • E’ auspicabile una nuova classificazione della severità dell’inquinamento in modo da renderla più utilizzabile e confrontabile su base internazionale. Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  5. Sintesi della ‘Technical Session’ dello SC C4 • PS3 - EMC and EMF Assessment and Mitigation of Associated Problems – Main Conclusions • La caratterizzazione delle interferenze elettromagnetiche (EMI) radiate da sottostazioni con isolamento in aria (AIS) e isolate in gas (GIS) mediante misure adeguate è un passo fondamentale al fine di garantirne la compatibità elettromagnetica con i circuiti secondari e con i sistemi digitali a relé. • Le tecniche di schermatura dei campi elettromagnetici prodotti dai cavi di potenza interrati EMF e dai trasformatori delle sottostazioni sono tra i punti più importanti da tenere in considerazione nella messa a punto degli standard Europei. Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  6. Sintesi della ‘Technical Session’ dello SC C4 • PS4 - Coordination of Power Quality Levels Between Customers and Various Players– Main Conclusions • Qualche difficoltà nell’applicazione di IEC Standards per il coordinamento dei livelli armonici tra utility e customer nei sistemi di potenza di ampia estensione. • Il monitoraggio e la valutazione degli indici di qualità per la PQ, così come definiti dal CIGRÉ WG C4.07, sono utili strumenti per migliorare l’affidabilità e la continuità del servizio delle reti di potenza Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  7. Riunione del comitato di studio C4 • Punti essenziali discussi • Partecipanti circa 40 fra Membri Esperti ed invitati. • Per l’Italia erano presenti: • Paola Bresesti – CESI Ricerca – Nuovo SC Secretary • Sandro Corsi – CESI • Carlo Alberto Nucci – Università di Bologna – Nuovo SC Chairman • Il past SC Chairman P. Kundur ha menzionato quanto riportato da A. Bolza (past Chairman del TC) all’ultima riunione del TC a Interlaken: difficoltà dei NC ad allocare gli esperti nello SC C4  paper su Electra by P. Kundur e C.A. Nucci per chiarire gli scopi dello SC C4 • E’ stata incoraggiata la presenza di “young experts” in Cigre activities • Sono state discusse le attività dello SC, degli AG, dei WG, delle TF. Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  8. System Technical Performance Convenor : C.A. Nucci (Italy)) Advisory Group C4.5 (set up 2002) Secretary Organisation and liaison with TGs P. Bresesti (Itlay) T. Correia de Barros (Portugal) Advisory Group C4.1 (set up 2002) Advisory Group C4.2 (set up 2002) Advisory Group C4.3 (set up 2002) Advisory Group C4.4 (set up 2002) Advisory Group C4.6 (set up 2004) Power Quality EMC Insulation Coordination Lightning Power Security Assessment R. Koch (South Africa) J. Hoeffelman (Belgium) C. Neumann (Germany) M. Ishii (Japan) K. Uhlen (Norway) JWG C4.101 (1999-2006) WG C4.201 (2004-2007) WG C4.301 (2005-2007) WG C4.401 WG C4.601 (2004-2008) Power Quality General Aspects EMC in HV substations Procedures for station and OHL Lightning Power System Security Assessment Convenor : E. Gunther (USA) and Generating Stations insulation coordination Convenor : C.A. Nucci (Italy) Convenor : P. Pourbeik (USA) Joint CIRED - CIGRE WG Convener: P. Pretorius (South Africa) Convenor : A. Xemard (France) TF C4.102 (2003-2006) JWG C4.202 (2004-2007) WG C4.302 JWG C4.402 TF C4.602 Voltage dips prediction tools EMC with communication circuits Dielectric withstand characteristics Protection of MV and LV networks Coordinated Voltage Control in Convenor : J.M. Velasco (Spain) LV systems and metallic structures of electrical insulation against lightning Transmission Networks Convenor : L.E. Juhlin (Sweden) Convenor : G. Gela (USA) Convenor : F. Rachidi (CH) Convenor : N. Martins (Brazil) WG C4.303 JWG C4.103 (2003-2006) TF C4.203 (2001-2005) TF C4.403 Pollution and Environmental Influence Emission limits for disturbing loads ELF field measurement and modelling Lightning induced overvoltages on Electrical Performance Convenor : G. Beaulieu (Canada) Convenor : F. Deschamps (France) Convenor : C.A. Nucci (Italy) Convener: C. Engelbrecht (NL) Joint CIRED-CIGRE WG JWG C4.105 (2005-2008) TF C4.204 (2001-2004) TF C4.404 Benchmarking of Power Quality Magnetic field Lightning location system data Performances in Transmission systems: mitigation techniques Convenor : G. Diendorfer (Austria) Convenor : Mark McGranaghan (US) Convenor : E. Salinas (Sweden) and H. Torres (Columbia) JWG C4.106 (2005-2007) TF C4.205 (2004-2006) TF C4.405 Instrument Test Protocols Characterization of Magnetic Lightning interception Convenor : Erich Gunther (US) Fields Levels Convenor : V. Cooray (Sweden) Convenor : J. Hoeffelman (Belgium) and Takatoshi Shindo (Japan) JWG C4.107 (2005-2008) TF C4.406 Economic Framework for Voltage Q Performance of grounding electrodes Convenor : JL. Gutierrez Iglesias for lightning currents (Spain) Convenor : S. Visacro (Brazil) TF C4.108 (2005-2007) Review of Flicker Objectives for HV MV and LV systems Convenor : Arlt Detmar (Germany) JTF C4.109 (2005-2007) Emission Assesment Techniques Convenor : E. De Jaeger (Belgium) JWG C4.110 (2005-2007) Equipment voltage dip immunity used in customer installations: Convenor : Math Bollen (Sweden) Present CIGRE SC C4 Organization

  9. Riunione del comitato di studio C4 • Advisory Group ReportsAG C4.1: Power Quality (R. Koch)AG C4.2: EMC (J. Hoeffelman)AG C4.3: Insulation Coordination (C. Neumann)AG C4.4: Lightning (M. Ishii)AG C4.5: Organization and Liaison with TGs (M.T. C.de Barros)AG C4.6: Power System Security Assessment (Kjetil Uhlen) • “Feedback” dal WS on PS Stability & Control, Paris, Aug 25, 2006. • Presentazione del “TF C4.602 Final Report: Coordinated Voltage Control in Transmission Networks” (convenors: N. Martins e S. Corsi) • Programma preliminare del 2007 Symposium in Zagreb: April 18-20 “Transient Phenomena in Large Electric Power Systems, che sarà preceduto da Tutorials Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  10. Riunione del comitato di studio C4 AG C4.1: Power Quality – Work in progress New Nearing completion To be terminated Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  11. Comitato di studio C4: pubblicazioni • AG 4.2: Electromagnetic Compatibility • Reports published in 2005 and 2006 • JWG C4.202 "EMC with communication circuits, LV systems and metallic • structures“ – Convener: Lars-Erik Juhlin • -TB 290: Guide for ac corrosion on metallic pipelines due to influence from • ac power lines. (Electra - April 2006) • -TB 266: Protection Measures for Radio Base Stations sited on Power Liner • Towers (Electra - February 2005) • - TB 275: Methods for measuring the earth of transmission towers equipped • with earth wires (Electra - June 2005). Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  12. Comitato di studio C4: pubblicazioni(2) • AG 4.4. Lightning • Reports published in 2005 and 2006 • TF C4.401 “Lightning Induced Overvoltages (LIOV)” – Convener: Carlo Alberto Nucci • - CIGRE report : "Lightning-induced voltages on overhead power lines. Part • III: Sensitivity Analysis" on the SC C4 website • - Extended summary published on Electra No. 222, pp.27-30, October 2005. • CIGRE-CIRED JWG C4.402 “Protection of MV and LV Networks against • Lightning” – Convener: Farhad Rachidi • - Technical Brochure No. 287 "Protection of MV and LV networks against • lightning. Part 1: "Common topics" in press. • - Summary on Electra No. 224, pp.47-51, February 2006. Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006

  13. Comitato di studio C4: soggetti preferenziali per il 2008 • Soggetto preferenziale 1 • PS 1 -How can system technical performance be specified, evaluated, and improvedby considering: • New techniques, tools, and application experiences related to electromagnetic compatibility, insulation coordination, lightning protection, power quality and power system security. • System technical performance indices and their impact on customers, asset owners and regulators. • The influence of environmental stresses (such as lightning and pollution). • The interaction of electrical equipment and customer installations with the power system. Giornata di diffusione dei risultati della sessione Cigre 2006 – Milano, 30 ottobre 2006