CoE3DJ4 Digital Systems Design. Chapter 5: Serial Port Operation. Serial port. 8051 includes an on-chip serial port Hardware access to the port is through TXD and RXD (Port 3 bits 1 and 0) Serial port is full duplex (simultaneous transmission and reception)
E N D
CoE3DJ4Digital Systems Design Chapter 5: Serial Port Operation
Serial port • 8051 includes an on-chip serial port • Hardware access to the port is through TXD and RXD (Port 3 bits 1 and 0) • Serial port is full duplex (simultaneous transmission and reception) • Note: In Mode 0, it is half duplex • Serial port has a receiving buffering allowing one character to be received and held in a buffer while a second character is received • Two registers SBUF and SCON provide access to the serial port • Serial buffer (SBUF) is in fact two buffers one write only for transmission and one read-only for receiving
The SCON Register • SMO, SM1, SM2 Serial Mode Control Bits SM0 SM1 Mode Baud Rate Description 0 0 0 fosc/12 8-bit shift register 0 1 1 variable 8-bit UART • 0 2 fosc/32 or fosc/64 9-bit UART 1 1 3 variable 9-bit UART • SM2 Multiprocessor Mode Control Bit • 1 = Multi-processor mode • 0 = Normal mode • REN Receiver Enable Bit • 1 = Receive Enable • 0 = Receive Disabled • TB8 9th Transmit Bit Enabled only in modes 2 and 3 • RB8 9th Bit Received Used in modes 2 and 3 • RI, TI Serial Interrupts • RI is set to indicate receipt of a serial word and TI is set to indicate completion of a serial transmission.
Modes • Mode of operation of serial port is set by writing to SCON. • Serial port has four modes of operation selected by writing 1s and 0s to SM0 and SM1 bits in SCON • Mode 0 puts the serial port in 8-bit shift register mode • Serial data enter and exit through RXD. • TXD serves as clock (outputs shift clock) • Eight bits are transmitted or received with the LSB first • Baud rate is fixed at 1/12th of on-chip oscillator • Transmission is initiated by any instruction that writes data to SBUF • Data are shifted out on RXD line with clock pulses sent out the TXD
Mode 0 • Each transmitted bit is valid on RXD pin for one machine cycle • Reception is initiated as soon as REN bit is set to 1 and the receive interrupt (RI) bit is cleared. • Usually, REN is set at the beginning of the program to initialize the serial port, then RI is cleared to start a data input operation. • As soon as RI is cleared, the shift clock will be produced on the TxD pin. • At the beginning of the following machine cycle, data will be clocked in from the RxD line. • The clocking occurs on the rising edge of the TxD line. • After the 8th clocking cycle, the data is copied to SBUF and the RI bit is set. • It is up to the attached circuitry to provide data on RXD line synchronized by the clock signal on TXD.
Mode 1 • Mode 1 is an 8-bit UART with variable baud rate • UART (universal asynchronous receiver/transmitter): a device that receives and transmits serial data with each data character preceded by a start bit (low) and followed by a stop bit (high) • In mode 1, 10 bit are transmitted on TXD or received on RXD • These consist of a start bit (always 0), eight data bits (LSB first) and stop bit (always 1) • For receive operation, stop bit goes into RB8 in SCON • Baud rate is set by timer 1.
Framing • An 8-bit message needs to be “framed” so that the receiver can detect correctly its beginning and end. • Standard framing: • Start bit – always 0, Stop bit – always 1. • Optional parity bit • The message now becomes: • Start bit (10), LSB, …, MSB, <parity bit>, Stop bit (1), Time
Mode 1 • Transmission is initiated by writing to SBUF • Shifted data are outputted on the TXD line beginning with start bit and followed by eight bit data bits then stop bit • The transmit interrupt (TI) flag is set as soon as the stop bit appears on TxD.
Mode 1 • Reception is initiated by a 1 to 0 transition on RXD (assuming REN is 1). • The start bit is skipped and eight data bits are clocked into the serial port shift register • When all eight bits have been clocked in, the following occur: • Ninth bit (stop bit) is clocked into RB8 in SCON • SBUF is loaded with eight data bits • Receiver interrupt flag (RI) is set • These only occur if following conditions exist: • RI=0 (ensures software has read the previous character) • SM2=0 (applies in multiprocessor communications)
Modes 2 & 3 • Mode 2: 9-bit UART with fixed baud rate • Eleven bits are transmitted or received: a start bit, eight data bits, a programmable ninth bit and a stop bit • On transmission, the ninth bit is whatever has been put in TB8 in SCON • On reception, the ninth bit received is placed in RB8 • Baud rate in mode 2 is either1/32nd or 1/64th on-chip oscillator • Mode 3: 9-bit UART with variable baud rate • Mode 3 is same as Mode 2 except baud rate is programmable and provided by Timer 1
Initialization and Accessing • Receiver enable bit REN in SCON must be set by software to enable reception of characters • This is done at the beginning of a program when port is initialized • SETB REN • MOV SCON, #xxx1xxxxB • Ninth data bit transmitted in modes 2 and 3 must be loaded into TB8 by software • Ninth bit received is placed in RB8
Initialization and Accessing • A common use for ninth data bit is to add parity to a character • P bit in PSW is set or cleared every machine cycle to establish even parity with bits in accumulator • Example: transmitting eight bits in accumulator with an even parity added in ninth bit: MOV C,P MOV TB8,C MOV SBUF,A • Odd parity MOV C,P CPL C MOV TB8,C MOV SBUF, A
Initialization and Accessing • RI and TI in SCON play an important role in 8051 serial communications • Both bits are set by hardware but must be cleared by software • Typically RI is set at the end of character reception and indicates “receive buffer full” • If software wishes to input a character from the device connected to serial port, it must wait until RI is set, then clear RI and read character from SBUF WAIT: JNB RI, WAIT CLR RI MOV A, SBUF
Initialization and Accessing • TI is set at the end of character transmission and indicates “transmit buffer empty”. • If software wishes to send a character to the device connected to the serial port, it must first check that the serial port is ready. WAIT: JNB TI, WAIT CLR TI MOV SBUF, A
Baud rate • Baud rate is fixed in modes 0 and 2 • In mode 0 it is always on-chip oscillator frequency divided by 12 • Default baud rate for mode 2 (after system reset) is oscillator frequency divided by 64 • Bit 7 of PCON is the SMOD bit • Setting SMOD doubles the baud rate in mode 2 to 1/32nd of oscillator frequency • Since PCON is not bit-addressable, setting SMOD has to be done using the following approach: MOV A, PCON SETB ACC.7 MOV PCON,A
Baud rate • The baud rates in Modes 1 and 3 are determined by Timer1overflow rate • Since timer operates at a relatively high frequency, it is further divided by 32 (or 16 if SMOD=1) before driving the serial port • The usual technique for baud rate generation is to initialize TMOD for 8-bit auto-reload mode (mode 3) and put the correct reload value in TH1 to yield proper overflow rate for baud rate
Serial port • Example: 1200 baud operation: BAUD RATE=TIMER 1 OVERFLOW RATE / 32 TIMER 1 OVERFLOW RATE =1200*32=38.4kHz • If a 12 MHz oscillator is used, timer 1 is clocked at 1 MHZ (1000 kHz). • Since the timer must overflow at a rate of 38.4 kHz and the timer is clocked at 1000 kHz, an overflow is required every 1000/38.4=26.04 clocks. • Since timer counts up and overflows on FF to 00 transition, 26 counts less than 0 is the required reload value for TH1: MOV TH1, #-26 • Table 5-3 gives reload values for different baud rates
Steps to Transmit a Byte • Program T1 for Mode2 (TMOD 0x20) • Load TH1 and TL1 with the initial value (baud rate dependant) (TH1 FD / FA / F4 / E8) • Program SCON for Mode1 (SCON 0x50) • Start Timer1 (SETB TR1) • Clear TI • Load SBUF with the byte to be transferred (SBUF byte) • Wait until TI becomes 1 (a wait loop using: JNB TI) • Go back to Step5 for next byte
Examples: Transmit a character • Transfer ASCII “A” serially at 9600 baud continuously START: MOV TMOD, #20H ;Put T1 in mode2 MOV TH1, #-7 ;9600 baud MOV SCON, #50H ;8b, 1stop, 1start, REN enabled SETB TR1 ;start timer T1 AGAIN: CLR TI ;ready to transmit MOV SBUF, #’A’ ;letter A is to be transmitted HERE: JNB TI, HERE ;poll TI until all the bits are transmitted SJMP AGAIN ;loop (forever loop)
Steps to Receive a Byte • Program T1 for Mode2 (TMOD 0x20) • Load TH1 and TL1 with the initial value (baud rate dependant)(TH1 FD / FA / F4 / E8) • Program SCON for Mode1 (SCON 0x50) • Start Timer1 (SETB TR1) • Clear RI • Wait until RI becomes 1 (a wait loop using JNB RI) • Store SBUF (A SBUF) • Go back to Step5 for next byte
Example: Receive Data • Receive bytes serially and display them on P1, continuously. START: MOV TMOD, #20H ;T1 in mode 2 MOV TH1, #-7 ;9600 baud MOV SCON, #50H ;8b, 1start, 1stop SETB TR1 ;start T1 AGAIN: CLR RI ;ready to receive a byte HERE: JNB RI, HERE ;wait until one byte is Rx-ed MOV A, SBUF ;read the received byte from SBUF MOV P1, A ;display on P1 SJMP AGAIN ;loop forever