1 / 8

Session plan for E 3.1.2. Intrinsic hydrocarbon yields and photon efficiencies

Session plan for E 3.1.2. Intrinsic hydrocarbon yields and photon efficiencies. Motivation Shot list (i) setup pulses (ii) C 2 H 4 and H 2 gas injections (iii) CD 4 and D 2 gas injections Previous attempts (see M. Stamp – TFE meeting 3.2.2004). S. Brezinsek, M. Stamp,

mina
Download Presentation

Session plan for E 3.1.2. Intrinsic hydrocarbon yields and photon efficiencies

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Session plan for E 3.1.2. Intrinsic hydrocarbon yields and photon efficiencies • Motivation • Shot list (i) setup pulses (ii) C2H4 and H2 gas injections (iii) CD4 and D2 gas injections • Previous attempts (see M. Stamp – TFE meeting 3.2.2004) S. Brezinsek, M. Stamp, A. Pospieszczyk, A. Meigs

  2. Motivation Chemical erosionyield • Determination of intrinsic hydrocarbon flux by means of an in-situ calibration with injection of hydrocarbons • Hydrocarbon flux • Methane family • Ethane family • Determination of conversion factors (D/XB-values): photon flux ~ particle flux • Dependence on the gas injection location and the strike point position • Reference discharges with H2 / D2 injection through the same GIMs!

  3. Shot list (setup pulse) • Setup pulses: • fuelling efficiency • density matching No success in the last session due to NBI problems!

  4. Shot list (C2H4 puff and H2 reference) GIM 11 is not available in the moment!

  5. Pulse setup pulse 3 - 8 (2.5 MA) variable strike point position / constant gas puff through either GIM 9,10 or 12 • high clearance discharges • large sweep of strike points Scheme was successful in discharge # 62729 (C2H4 in D plasma)

  6. Previous attempts SOL PFR vt ht Now: C2H4 injection into H! Discrimination between CH from the wall and from the C2H4 break-up is difficult!

  7. Shot list (CD4 puff and D2 reference) Now: CD4 injection (GCD4 =2x1021 s-1) into a H plasma! Discrimination between CH from the wall and from the CD4 break-up might be possible!

  8. Diagnostic settings KME: 4.3 s or 6.3 s exposure time, full spectrum from 382 nm - 680 nm, all fibres 100% KS3A: standard settings KS3B: CD A-X band settings: 430.3 nm and 500 ms exposure time, Da standard settings KT3A: CD A-X band settings: 431.2 nm and 250 ms exposure time – 1200 grating CD B-X band setting: 390.5 nm and 250 ms exposure time – 1200 grating KT3B: C2 d-a band (Dv=0) settings: 504.0 nm and 250 ms exposure time – 1200 grating CD A-X band settings: 429.0 nm and 250 ms exposure time – 1200 grating KT3C: CI settings: 875 nm and 250 ms exposure time – 600 grating KL1: standard settings: time window between 55 s –65 s and KY4D, KY3, KY6, KE9D, KB1, KT2/4

More Related