Introducing Siemens Q-Series RH & RHT Room Sensors

Introducing Siemens Q-Series RH & RHT Room Sensors. Q-Series Room Humidity Sensors – What’s So Exciting?. Same housing, but new technology! Many new features and benefits Versions for many applications Signal options Accuracy options Easy to service Very affordable!!.

ophrah
Download Presentation

Introducing Siemens Q-Series RH & RHT Room Sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Introducing Siemens Q-Series RH & RHT Room Sensors

  2. Q-Series Room Humidity Sensors – What’s So Exciting? • Same housing, but new technology! • Many new features and benefits • Versions for many applications • Signal options • Accuracy options • Easy to service • Very affordable!!

  3. Q-Series RH Room Sensors – Applications Use in all standard applications for building control: • HVAC Installations • Energy Management Systems • VAV and Fan Control • Dual Duct Applications • Critical Environments

  4. Q-Series RH Room Sensors – Features • Offered as 5/3%, or 2%versions • Removable, replaceable sensing tips • Available as RH sensing only or RH with Temperature • A variety of output signals available

  5. Q-Series RH Room Sensors – Design Details • Temperature-compensated element – superior accuracy! • Digital signal – minimizes reading errors • Circuit layout allows fit into existing room housing • Common look with temp sensors • Great for retrofits – same look & feel!

  6. Q-Series RH Room Sensors – Accuracies • 5% (3%) Versions • 5% accuracy over range of 0-95% relative humidity • 3% accuracy over the “comfort” range (30% to 70% r.h.) • 2% Versions • Accuracy over the range of 0-95% relative humidity • Removable, replaceable sensing tips

  7. Q-Series RH Room Sensors – Signals • Active signals for Humidity or Temperature • 0-10 Volts; may be powered by AC or DC Voltage • 4 to 20mA current • Resistive signals for Temperature • 1K Platinum RTD (385 Alpha) • 1K Nickel RTD (compatible with Siemens VFDs) • 10K NTC Type II for LON TEC or other BAS’s • 10K NTC Type III for retrofitting other BAS’s Note: on RH&T versions with passive temp, Only 0-10Volt output is offered for rh signal

  8. Q-Series RH Room Sensors – Competitive Summary X Offered -- Not Offered

  9. Q-Series RH Room Sensors – Documentation • Specification Sheet – 149-994 • Installation Instructions – 129-415 • Product Selection Guide – 153-857P3

  10. Q-Series RH Room Sensors -Selling Arguments vs. Honeywell/Hycal HCT829 • Available as humidity only units • Does not measure accurately above 90%. • Only available in a 4-20 mA version. • Element does not recover well from 100% saturation. • Humidity element is not replaceable. • Honeywell offers no versions with certification

  11. Q-Series RH Room Sensors -Selling Arguments vs. Johnson Controls (HE-67xx) • Does not offer a removable, replaceable tip • Only measures up to 90% relative humidity • Cannot measure at 4% accuracy or better over the 80% rh • On RH&T versions, sensor not temperature range selectable • No 0-10 Volt temperature signal is offered for temperature • Element may not recover from 100% saturation

  12. Q-Series RH Room Sensors -Selling Arguments vs. Veris Industries HNR/HXR • Veris sensors not UL listed • Product only measures accurately up to 90% rh • Devices not range selectable on temp versions.

  13. Q-Series RH Room Sensors -Selling Arguments vs. ACI A/RHx-R types • Sensing element not removable or replaceable • Only accurate to 95% relative humidity • SBT’s device measures from 0-100% for the 2% model • ACI product not temperature range selectable • ACI does not offer a UL listed product

  14. Selling Arguments vs. GE/ General Eastern -Microline (MRH and MRHTx types) • No removable tip – must replace entire unit! • Measures over a 20-95% rh range only • MRHT products don’t have temperature range selectability • Temperature output signal is only offered as a 4-20mA • Poor accuracy Tests vs. GEI sensors under extreme conditions showed new Siemens sensors perform much better than Microline products!

  15. Q-Series RH Room Sensors -Selling Arguments vs. Kele • Does not have their own product • Resells ACI, Hycal/Honeywell, Vaisala, and GEI products • Relies on service to gain market share

  16. Q-Series RH Room Sensors -Selling Arguments vs. BAPI the BA/H200, BA/H300 • Only measures to 95% rh • Does not offer temperature range selectable • Does not offer certified sensors • Sensors are not UL listed • Element will not recover from 100% saturation

  17. Q-Series RH Room Sensors Selling Arguments vs. Vaisala HMR60 or HMR70 • Does not offer temperature range selectable • Does not offer UL listed devices • Very expensive!! • For a much lower price, Siemens’ Q-Series humidity sensors • offer all the accuracy and reliability you need!

  18. Q-Series RH Room Sensor – Replacement Listing

  19. Q-Series RH Sensors – Ordering Example: 0-10V Room, RH 5% QFA2000.WU

  20. Order Your Q-Series Room Humidity Sensors Today!