1. Preferred Utilities Manufacturing Corp.
2. Tank Gauge D3 Tank Gauge
Single Tank Applications
Wire Float Available for Limited Tank Clearance
Standard 4-20 mA output
3. D5 Tank Gauge
4. Wire Float Level Sensor
5. Wire Float Level Sensor Requires only 14 Inches of Head Room
Reads tanks 36 to 145 inches Tall
Buna-N Float
Requires only a 4 inch 125# Flange
Easy to Install and Calibrate
Can Be Installed in an Empty or Full Tank
Can be mechanically tested in place
Intrinsically Safe
6. Versatility Solves Site Problems
7. I plan to spend about 5 minutes showing them how they load the software, 10 minutes going over how the software is used. I plan to go through all the blanks to tell them what needs to go where and what fields are more important than others. I will show them the printing features here also. The heart of the program will be to go through 4 examples at 10 minutes each. With each example if will first give them the information a typical engineer might give them over the phone and then work up a example for each. These for examples will show each of the four systems shown at the beginning of the sizing program. The last 5 minutes will be spent talking about how they, the salespeople, can use this. I will talk about how they can give this to a “special engineer” at no cost instead of the typical $150 price. Secondly they can use the program to pull people in for a seminar or lunch and learn. Also they can follow up a seminar buy calling people to say they have a few left over and the salesperson can stop in to drop it off. I will also highlight the other items on the CD. With this slide the program will continue by using the PC to show the actual program. Hand outs will include these 3 slides along with the 4 printouts (reports) from the example applications. I plan to spend about 5 minutes showing them how they load the software, 10 minutes going over how the software is used. I plan to go through all the blanks to tell them what needs to go where and what fields are more important than others. I will show them the printing features here also. The heart of the program will be to go through 4 examples at 10 minutes each. With each example if will first give them the information a typical engineer might give them over the phone and then work up a example for each. These for examples will show each of the four systems shown at the beginning of the sizing program. The last 5 minutes will be spent talking about how they, the salespeople, can use this. I will talk about how they can give this to a “special engineer” at no cost instead of the typical $150 price. Secondly they can use the program to pull people in for a seminar or lunch and learn. Also they can follow up a seminar buy calling people to say they have a few left over and the salesperson can stop in to drop it off. I will also highlight the other items on the CD. With this slide the program will continue by using the PC to show the actual program. Hand outs will include these 3 slides along with the 4 printouts (reports) from the example applications.
8. Tank Gauge Installation
9. Underground Storage Tank (UST)
Pipe leak detection requirements, pitch double wall pipe containment to the piping sump on the tank
Typical pipe pitch is 1/8”/ft, long linear runs could present problems, might require a second sump
All tanks
Discriminating leak detector for the Dry Interstitial space of the tank
Small cost to add on a new installation, major liability mitigationSmall cost to add on a new installation, major liability mitigation
10. Fuel Leak Detection
11. Leak Sensor Test Module
12. HD-A1 Leak Detector Factory Mutual Approved
Intrinsically Safe
Monitors for both Oil and Water
Three Detectors per Tank Gauge
Manual Testing of Unit
Completely Potted for Long Life
Fail Safe Circuitry
13. Level 3 Day Tank
14. Leak Sensor
16. Floor Leak Detector
17. 2nd Manhole with Tank Access & Leak Detectors Max flow / max viscosity for calculations
use our program
use 100 mesh for e-gen sets.Max flow / max viscosity for calculations
use our program
use 100 mesh for e-gen sets.
18. Leak Sensor Close-up Use solid line in our applications
use our program - it will give you a nice print out. Use solid line in our applications
use our program - it will give you a nice print out.
19. Leak Detector
20. Leak Sensor Test Modules
21. Double Wall Containment Piping
22. Day Tank Vent Detector
23. Pump Set Leak Detector
24. Single Source Fuel Handling
25. Preferred Utilities Manufacturing Corp